Segmentation of Multiple Heart Cavities in 3-D Transesophageal Ultrasound Images

被引:13
|
作者
Haak, Alexander [1 ]
Vegas-Sanchez-Ferrero, Gonzalo [2 ,3 ,4 ]
Mulder, Harriet W. [8 ]
Ren, Ben [5 ]
Kirisli, Hortense A. [6 ,7 ]
Metz, Coert [6 ,7 ]
van Burken, Gerard [1 ]
van Stralen, Marijn [8 ]
Pluim, Josien P. W. [8 ]
van der Steen, Antonius F. W. [1 ]
van Walsum, Theo [6 ,7 ]
Bosch, Johannes G. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Appl Chest Imaging Lab, Boston, MA 02115 USA
[3] Univ Politecn Madrid, ETSI Telecomunicac, Biomed Image Technol Lab BIT, E-28040 Madrid, Spain
[4] CIBER BBN, Madrid 28040, Spain
[5] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[6] Erasmus MC, Biomed Imaging Grp Rotterdam, Dept Med Informat, NL-3000 CA Rotterdam, Netherlands
[7] Erasmus MC, Biomed Imaging Grp Rotterdam, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
[8] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
关键词
ACTIVE SHAPE MODELS; ATRIAL-FIBRILLATION; ECHOCARDIOGRAPHIC IMAGES; SPECKLE; QUANTIFICATION; REGISTRATION; ASSOCIATION; FLUOROSCOPY; STATISTICS; SCANS;
D O I
10.1109/TUFFC.2013.006228
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations. Dice coefficients and point-to-surface distances were used to determine segmentation accuracy. ASM segmentations were successful in 19 of 20 cases. The median Dice coefficient for all successful segmentations versus the average observer ranged from 90% to 71% compared with an inter-observer range of 95% to 84%. The agreement against the CTA segmentations was slightly lower with a median Dice coefficient between 85% and 57%. In this work, we successfully showed the accuracy and robustness of the proposed multi-cavity segmentation scheme. This is a promising development for intraoperative procedure guidance, e.g., in cardiac electrophysiology.
引用
收藏
页码:1179 / 1189
页数:11
相关论文
共 50 条
  • [1] IMPROVED SEGMENTATION OF MULTIPLE CAVITIES OF THE HEART IN WIDE-VIEW 3-D TRANSESOPHAGEAL ECHOCARDIOGRAMS
    Haak, Alexander
    Ren, Ben
    Mulder, Harriet W.
    Vegas-Sanchez-Ferrero, Gonzalo
    van Burken, Gerard
    van der Steen, Antonius F. W.
    van Stralen, Marijn
    Pluim, Josien P. W.
    van Walsum, Theo
    Bosch, Johannes G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (07): : 1991 - 2000
  • [2] Simultaneous segmentation of multiple heart cavities in 3D transesophageal echocardiograms
    Haak, Alexander
    Vegas-Sanchez-Ferrero, Gonzalo
    Mulder, Harriet H.
    Kirisli, Hortense A.
    Baka, Nora
    Metz, Coert
    Klein, Stefan
    Ren, Ben
    van Burken, Gerard
    Pluim, Josien P. W.
    van der Steen, Antonius F. W.
    van Walsum, Theo
    Bosch, Johannes G.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 655 - 658
  • [3] Segmentation of multiple heart cavities in wide-view fused 3D transesophageal echocardiograms
    Haak, Alexander
    Mulder, Harriet W.
    Ren, Ben
    Vegas-Sanchez-Ferrero, Gonzalo
    van Burken, Gerard
    van der Steen, Antonius F. W.
    van Stralen, Marijn
    Pluim, Josien P. W.
    van Walsum, Theo
    Bosch, Johannes G.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 691 - 694
  • [4] Automatic Segmentation of Antenatal 3-D Ultrasound Images
    Anquez, Jeremie
    Angelini, Elsa D.
    Grange, Gilles
    Bloch, Isabelle
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) : 1388 - 1400
  • [5] Visualization and segmentation techniques in 3-D ultrasound images
    Fenster, A
    Downey, DB
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 737 - 742
  • [6] Automatic segmentation of heart cavities in multidimensional ultrasound images
    Wolf, I
    Glombitza, G
    De Simone, R
    Meinzer, HP
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 273 - 283
  • [7] Fast Segmentation of the Left Atrial Appendage in 3-D Transesophageal Echocardiographic Images
    Morais, Pedro
    Queiros, Sandro
    De Meester, Pieter
    Budts, Werner
    Vilaca, Joao L.
    Tavares, Joao Manuel R. S.
    D'hooge, Jan
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (12) : 2332 - 2342
  • [8] Statistical segmentation of surgical instruments in 3-d ultrasound images
    Linguraru, Marius George
    Vasilyev, Nikolay V.
    Del Nido, Pedro J.
    Howe, Robert D.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (09): : 1428 - 1437
  • [9] Segmentation of the heart muscle in 3-d pediatric echocardiographic images
    Nillesen, Maartje M.
    Lopata, Richard G. P.
    Gerrits, Inge H.
    Kapusta, Livia
    Huisman, Henkjan J.
    Thijssen, Johan M.
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (09): : 1453 - 1462
  • [10] A 3-D Bilateral Filter for Speckle Reduction in 3-D Ultrasound Images for Cattle Follicle Segmentation
    Tang, Jinshan
    Guo, Shengwen
    PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 2485 - 2488