Instability of bovine insulin in poly(lactide-co-glycolide) (PLGA) microspheres

被引:0
|
作者
Uchida, T
Yagi, A
Oda, Y
Nakada, Y
Goto, S
机构
关键词
bovine insulin; poly(lactide-co-glicolide); protein delivery; degradation;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Biodegradable poly(lactide-co-glycolide) (PLGA; 50/50) microspheres containing bovine insulin as a model protein were prepared by an oil-in-oil (o/o) emulsion solvent evaporation process, When aluminum tristearate (0.15% (w/v)) was employed as a dispersing agent, the loading efficiency of insulin was almost 100% and the yield was over 80%, The average diameter of the PLGA microspheres always ranged between 100 and 200 mu m. Morphology study using a scanning electron micrograph showed smooth, spherical, fairly monodispersed PLGA microspheres containing insulin, In relation to release profile, the very low release rate of insulin was demonstrated (only 1% of insulin released after 7 d release test in pH 7.4 Tris buffer) for the PLGA microspheres, Nevertheless, the degradation of bovine insulin in PLGA microspheres was confirmed by high performance liquid chromatography. This degradation seemed to be caused by an acidic condition caused by poly(lactide-co-glycolide) polymer.
引用
收藏
页码:235 / 236
页数:2
相关论文
共 50 条
  • [1] RECENT DEVELOPMENTS WITH POLY(LACTIDE-CO-GLYCOLIDE) MICROSPHERES
    TICE, TR
    LABRIE, F
    MCRAEDEQUEURCE, A
    DILLON, DL
    GILLEY, RM
    MASON, DW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 152 - POLY
  • [2] Poly(lactide-co-glycolide) microspheres with good biocompatibility
    An, Runze
    Tang, Wenmin
    Zhao, Zhanpeng
    Liu, Wentao
    Kan, Liang
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2023, 25 (04) : 111 - 120
  • [3] Encapsulation of rotavirus into poly(lactide-co-glycolide) microspheres
    Sturesson, C
    Artursson, P
    Ghaderi, R
    Johansen, K
    Mirazimi, A
    Uhnoo, I
    Svensson, L
    Albertsson, AC
    Carlfors, J
    JOURNAL OF CONTROLLED RELEASE, 1999, 59 (03) : 377 - 389
  • [4] Microspheres of Poly (lactide-co-glycolide acid) (PLGA) for Agaricus Bisporus Lectin Drug Delivery
    Zhao, Shuang
    Wang, Hexiang
    Tong, Yen Wah
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1313 - +
  • [5] Poly(D,L)-lactide-co-glycolide (PLGA) microspheres as immunoadjuvant for Brugia malayi antigens
    Saini, Vinay
    Verma, Shiv Kumar
    Murthy, P. Kalpana
    Kohli, Dharmveer
    VACCINE, 2013, 31 (38) : 4183 - 4191
  • [6] INVITRO DEGRADATION OF POLYLACTIDE AND POLY(LACTIDE-CO-GLYCOLIDE) MICROSPHERES
    ZHU, JH
    SHEN, ZR
    WU, LT
    YANG, SL
    JOURNAL OF APPLIED POLYMER SCIENCE, 1991, 43 (11) : 2099 - 2106
  • [8] Physical properties of microspheres prepared by blending poly(lactide-co-glycolide) and poly lactide
    F ITO
    H YAMADA
    Bulletin of Materials Science, 2021, 44
  • [9] Physical properties of microspheres prepared by blending poly(lactide-co-glycolide) and poly lactide
    Ito, F.
    Yamada, H.
    BULLETIN OF MATERIALS SCIENCE, 2021, 44 (01)
  • [10] Triptorelin acetate-loaded poly(lactide-co-glycolide) (PLGA) microspheres for controlled drug delivery
    Kyonghee Park
    Goo Young Jung
    Myong-Ki Kim
    Mork Soon Park
    Yong Kook Shin
    Jae-Kwan Hwang
    Soon Hong Yuk
    Macromolecular Research, 2012, 20 : 847 - 851