MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems

被引:63
|
作者
Badano, A
Sempau, J
机构
[1] NIBIB, CDRH, Lab Assessment Med Imaging Syst, Rockville, MD 20857 USA
[2] Univ Politecn Catalunya, Inst Tecn Energet, E-08028 Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 06期
关键词
D O I
10.1088/0031-9155/51/6/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe MANTIS (Monte carlo x-rAy electroN opTical Imaging Simulation), a tool for simulating imaging systems that tracks x-rays, electrons and optical photons in arbitrary materials and complex geometries. The x-ray and electron transport and involved physics models are from the PENELOPE package, and the optical transport and corresponding physics models are from DETECT-II and include Fresnel refraction and reflection at material boundaries, bulk absorption and scattering. Complex geometries can be handled with the aid of the geometry routines included in PENELOPE. When x-rays or electrons interact and deposit energy in the scintillator, the code generates a number of optical quanta according to a user-selected model for the conversion process. The optical photons are then tracked until they reach an absorption event, which in some cases contributes to the output signal, or escape from the geometry. We demonstrate the capabilities of this new tool with respect to the statistics of the optical signal detected and to the three-dimensional point-response functions corresponding to columnar phosphor screens.
引用
收藏
页码:1545 / 1561
页数:17
相关论文
共 50 条
  • [1] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305
  • [2] X-ray spectra by means of Monte Carlo simulations for imaging applications
    Tirao, G.
    Quintana, C.
    Malano, F.
    Valente, M.
    [J]. X-RAY SPECTROMETRY, 2010, 39 (06) : 376 - 383
  • [3] Statistics of the scintillation output using a combined x-ray/electron/optical Monte Carlo method
    Badano, A
    Sempau, J
    Jennings, RJ
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 361 - 365
  • [4] Monte Carlo simulations of dual energy X-ray inspection systems
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    [J]. Qinghua Daxue Xuebao, 2006, 6 (813-816):
  • [5] Combined x-ray/electron/optical Monte Carlo code based on PENELOPE and DETECT-II
    Badano, A
    Sempau, J
    Boswell, JS
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 870 - 876
  • [6] Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization
    Kroc, Thomas K.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [7] Multiscale Monte Carlo Simulations for Advanced X-Ray Breast Imaging: Dosimetric Studies
    Trevisan Massera, R.
    Tomal, A.
    Thomson, R.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E308 - E309
  • [8] Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations
    Khanh Ai Tran
    Loan Thi Hong Truong
    Nhon Van Mai
    Phuong Nguyen Dang
    Dung Thi Thuy Vo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (07) : 1168 - 1174
  • [9] Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations
    Khanh Ai Tran
    Loan Thi Hong Truong
    Nhon Van Mai
    Phuong Nguyen Dang
    Dung Thi Thuy Vo
    [J]. Journal of the Korean Physical Society, 2016, 69 : 1168 - 1174
  • [10] ELECTRON MOMENTA IN MONTE CARLO X-RAY TRANSPORT
    VEIGELE, WJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1968, 39 (10) : 4781 - &