Use of preoperative visceral echo-color-Doppler in patients candidates to colonic surgery: preliminary report

被引:0
|
作者
Del Rio, P. [1 ]
Bertocchi, E. [1 ]
Sommaruga, L. [1 ]
Iapichino, G. [1 ]
Montana, C. [1 ]
Dell'abate, P. [1 ]
Sianesi, M. [1 ]
机构
[1] Univ Hosp Parma, Unit Gen Surg & Organ Transplantat, Dept Surg Sci, I-43100 Parma, Italy
关键词
Colectomy; Echocardiography; Doppler; Postoperative complications; Ileus; POSTOPERATIVE ILEUS; ANASTOMOTIC LEAKAGE; RANDOMIZED-TRIAL; CANCER SURGERY; RISK-FACTORS; RESECTION; NUTRITION; COLECTOMY; SCORE;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim. Postsurgical paralytic ileus is by definition an ileal paralysis longer than three days (72 hours) after a surgery on the gastrointestinal tract. At colorectal surgery we have performed on all candidates a visceral echo-color-Doppler to find a potential correlation with cardiovascular risk factors. Methods. We have tested patients undergone to colorectal surgical resection performed by laparoscopic and laparotomic surgery, looking for their atherosclerosis status using ultrasound scan, postsurgical complication, bowel digestive function, anastomotic leak. We have also analyzed for each case the value of glycemia, azoternia, creatinemia, cholesterolemia, triglyceridemia, leukocytemia, mean cell volume, hemoglobinemia, albuminemia and moreover age, disease, pathology localization, kind of surgery, weight and height, body mass index (BMI), ASA status (American Society of Anesthesiologists, electrocardiographic distortions, nicotine dependency, diabetes mellitus type I and II). Results. The study enrolled 23 patients, 10 male and 13 female. Middle age was 68.65 +/- 11.85 years (range 39-90). In the female subgroup mean age was 69.48 years (range 39-90), while in the male subgroup it was 68 years (range 54-81). In 17 cases out of 23 (73.9%) there was a delay in digestive function, of over 72 hours, with a mean time duration of the paralytic liens of 4.74 +/- 1.60 days (range 3-9). Furthermore a statistically significant correlation between albuminemia and hemoglobinemia presurgery values and lower sierical albuminemia presurgery values in patients who were canalized too late (P=0.03; P=0.041) was found. The non-parametrical values analysis sec. Kruskal-Wallis emphasized a significant correlation between the canalization day, the elettrocardiographic evidence of the pathological situation (P=0.023) and the patient's smoking history (0.023). Another significant value was the creatininemia value: lower values of creatininemia were related to a delayed canalization (P=0.035). Conclusion. The statistical analysis does not allow to highlight any correlation between the ultrasound diagnosis of atherosclerosis and the delayed canalization.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 23 条
  • [1] NONINVASIVE PREOPERATIVE EVALUATION OF CAROTID ATHEROMA - ECHO-COLOR-DOPPLER VERSUS DUPLEX SCANNING
    RIZZO, S
    CARDIA, G
    FULLONE, M
    REGINA, G
    VASCULAR SURGERY, 1993, 27 (05): : 357 - 362
  • [2] Noninvasive grading of the severity of portal hypertension in cirrhotic patients by echo-color-Doppler
    Bolognesi, M
    Sacerdoti, D
    Merkel, C
    Bombonato, G
    Gatta, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07): : 901 - 907
  • [3] Arterioportal fistulas, a rare cause of relevant portal hypertension in cirrhotic patients: Diagnostic usefulness of echo-color-Doppler
    Bolognesi, M
    Sacerdoti, D
    Bombonato, G
    Favaro, A
    Spadaro, L
    Merkel, C
    Gatta, A
    HEPATOLOGY, 1999, 30 (04) : 219A - 219A
  • [4] ASSOCIATION BETWEEN MICROVASCULAR AND MACROVASCULAR DAMAGE IN PATIENTS WITH SYSTEMIC SCLEROSIS: AN UPPER LIMB ECHO-COLOR-DOPPLER AND NAILFOLD VIDEOCAPILLAROSCOPY STUDY
    Montella, A.
    Corallo, C.
    Pastorelli, M.
    Capecchi, M.
    Voglino, M.
    Ruocco, G.
    Wolf, G.
    Giordano, N.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (06): : 1897 - 1902
  • [5] Liver involvement in a large cohort of patients with hereditary hemorrhagic telangiectasia:: Echo-color-Doppler vs multislice computed tomography study
    Buonamico, Paolo
    Suppressa, Patrizia
    Lenato, Gennaro M.
    Pasculli, Giovanna
    D'Ovidio, Francesco
    Memeo, Maurizio
    Scardapane, Arnaldo
    Sabba, Carlo
    JOURNAL OF HEPATOLOGY, 2008, 48 (05) : 811 - 820
  • [6] Use of an Esophageal Echo-Doppler Device During Liver Transplantation: Preliminary Report
    Perilli, V.
    Avolio, A. W.
    Sacco, T.
    Modesti, C.
    Gaspari, R.
    Caserta, R.
    Agnes, S.
    Sollazzi, L.
    TRANSPLANTATION PROCEEDINGS, 2009, 41 (01) : 198 - 200
  • [7] Preliminary Experience in the Use of Preoperative Echo-guided Left Stellate Ganglion Block in Patients Undergoing Cardiac Surgery
    Garneau, Sebastien Y.
    Deschamps, Alain
    Couture, Pierre
    Levesque, Sylvie
    Babin, Denis
    Lambert, Jean
    Tardif, Jean-Claude
    Perrault, Louis P.
    Denault, Andre Y.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (01) : 78 - 84
  • [8] Usefulness of 2D echo Doppler in the preoperative assessment of cystic fibrosis patients who are candidates for lung transplantation
    Vizza, CD
    Sciomer, S
    Della Rocca, G
    Di Roma, A
    Iacoboni, C
    Venuta, F
    Rendina, E
    Di Giacomo, T
    Padovani, D
    Lavalle, C
    Quattrucci, S
    Flaishman, I
    Cimino, G
    Antonelli, M
    Coloni, F
    Fedele, F
    TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) : 1628 - 1629
  • [10] USE OF DOPPLER COLOR-FLOW IMAGING FOR DIFFERENTIAL-DIAGNOSIS OF VASCULAR MALFORMATIONS - A PRELIMINARY-REPORT
    YOSHIDA, H
    YUSA, H
    UENO, E
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 53 (04) : 369 - 374