Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera

被引:13
|
作者
van Dijk, Joris D. [1 ,4 ]
van Dalen, Jorn A. [2 ]
Mouden, Mohamed [3 ]
Ottervanger, Jan Paul [3 ]
Knollema, Siert [1 ]
Slump, Cornelis H. [4 ]
Jager, Pieter L. [1 ]
机构
[1] Isala Hosp, Dept Nucl Med, POB 10400, NL-8000 GK Zwolle, Netherlands
[2] Isala Hosp, Dept Med Phys, Zwolle, Netherlands
[3] Isala Hosp, Dept Cardiol, Zwolle, Netherlands
[4] Univ Twente, MIRA Inst Biomed Technol & Tech Med, Enschede, Netherlands
关键词
Myocardial perfusion imaging (MPI); cadmium-zinc-telluride (CZT); patient motion; respiratory motion; motion correction; PERCUTANEOUS CORONARY INTERVENTION; QUANTITATIVE ASSESSMENT; VALIDATION;
D O I
10.1007/s12350-016-0571-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasive fractional flow reserve (FFR) measurement. Eight-minute stress acquisitions were reformatted into 1.0- and 20-second bins to detect respiratory motion (RM) and patient motion (PM), respectively. RM and PM were quantified and scans were automatically corrected. Total perfusion deficit (TPD) and SPECT interpretation-normal, equivocal, or abnormal-were compared between the noncorrected and corrected scans. Scans with a changed SPECT interpretation were compared with FFR, the reference standard. Average RM was 2.5 +/- 0.4 mm and maximal PM was 4.5 +/- 1.3 mm. RM correction influenced the diagnostic outcomes in two patients based on TPD changes >7% and in nine patients based on changed visual interpretation. In only four of these patients, the changed SPECT interpretation corresponded with FFR measurements. Correction for PM did not influence the diagnostic outcomes. Respiratory motion and patient motion were small. Motion correction did not appear to improve the diagnostic outcome and, hence, the added value seems limited in MPI using CZT-based SPECT cameras.
引用
收藏
页码:419 / 428
页数:10
相关论文
共 50 条
  • [1] Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera
    Joris D. van Dijk
    Jorn A. van Dalen
    Mohamed Mouden
    Jan Paul Ottervanger
    Siert Knollema
    Cornelis H. Slump
    Pieter L. Jager
    [J]. Journal of Nuclear Cardiology, 2018, 25 : 419 - 428
  • [2] Value of respiratory and patient motion correction in myocardial perfusion imaging using a CZT-based SPECT camera
    Van Dijk, Joris
    Dalen, Jorn
    Mouden, Mohamed
    Ottervanger, Jan Paul
    Knollema, Siert
    Slump, Cornelis
    Jager, Pieter
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [3] Simulation of Patient Motion with Myocardial Perfusion CZT SPECT: Data-Driven Motion Detection and Correction
    Daou, D.
    Sabbah, R.
    Alattar, Y.
    Coaguila, C.
    Boulahdour, H.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S337 - S337
  • [4] Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
    Lima, Ronaldo
    Peclat, Thais
    Soares, Thalita
    Ferreira, Caio
    Souza, Ana Carolina
    Camargo, Gabriel
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (01) : 245 - 251
  • [5] Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
    Ronaldo Lima
    Thais Peclat
    Thalita Soares
    Caio Ferreira
    Ana Carolina Souza
    Gabriel Camargo
    [J]. Journal of Nuclear Cardiology, 2017, 24 : 245 - 251
  • [6] Effects of respiration on myocardial perfusion imaging with a CZT SPECT camera
    Ko, Chi-Lun
    Wu, Yen-Wen
    Cheng, Mei-Fang
    Yen, Ruoh-Fang
    Tzen, Kai-Yuan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [7] Quantification of myocardial perfusion reserve using CZT-based dynamic SPECT: a feasibility study
    Slouwerhof, I.
    Jager, P.
    van Osch, J.
    Timmer, J.
    Slump, K.
    van Dalen, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S230 - S231
  • [8] Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT
    Yokota, Shu
    Mouden, Mohamed
    Ottervanger, Jan Paul
    Engbers, Elsemiek
    Knollema, Siert
    Timmer, Jorik R.
    Jager, Pieter L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 296 - 301
  • [9] Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT
    Shu Yokota
    Mohamed Mouden
    Jan Paul Ottervanger
    Elsemiek Engbers
    Siert Knollema
    Jorik R. Timmer
    Pieter L. Jager
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 296 - 301
  • [10] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    van Dijk, J. D.
    Mouden, M.
    Ottervanger, J.
    van Dalen, J. A.
    Knollema, S.
    Slump, C. H.
    Jager, P. L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S228 - S228