摘要
Based on the wavelet transform results of the transient signals from all ends of the line, a unit protection for high voltage power transmission line is presented. The attenuation effects of high voltage transmission line and busbar capacitance to high-frequency current signals are analyzed. The Transient Current Content Ration(TCCR), Transient Voltage Content Ratio (TVCR) and Transient Voltage Singularity Ratio (TVSR) are deduced according to the analysis of the differences during high frequency voltage transients at each end of the transmission line when in-zone faulted and out-zone faulted. Protection criterion using TCCR and protection criterion using TVSR are proposed. and the principles of protection settings are given. The wavelet modulus maxima of transient signals are used to calculate TCCR and TVSR. Simulation experiments of different faults with EMTP are carried out to test and analyze the protection criteria. A 100kHz sampling rate is used in the simulation experiments. According to the simulation results, the protection criteria prove to be simple, reliable and good for whole line protection.
引用
收藏
页码:205 / +
页数:2
相关论文
共 50 条
  • [1] A novel unit transient based protection criterion for high-voltage power transmission line
    Xia, MC
    Huang, YH
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C275 - C278
  • [2] A Backup Protection Based on Compensated Voltage for Transmission Lines Connected to Wind Power Plants
    Wang, Hao
    Li, Xiaopeng
    Dong, Xinzhou
    Jiang, Xiaofeng
    ELECTRONICS, 2024, 13 (04)
  • [3] Transient current similarity based protection for wind farm transmission lines
    Jia, Ke
    Li, Yanbin
    Fang, Yu
    Zheng, Liming
    Bi, Tianshu
    Yang, Qixun
    APPLIED ENERGY, 2018, 225 : 42 - 51
  • [4] WAVELET ANALYSIS IN TRANSIENT BASED PROTECTION FOR POWER SYSTEM HIGH VOLTAGE TRANSMISSION LINE
    Xia, Ming-Chao
    Huang, Yi-Zhuang
    PROCEEDINGS OF THE 2010 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, 2010, : 427 - 430
  • [5] Transient based protection for transmission lines
    Bo, ZQ
    Weller, G
    Dai, FT
    Yang, QX
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1067 - 1071
  • [6] Non-unit transient based boundary protection for UHV transmission lines
    Luo, S. B.
    Gao, H. L.
    Wang, D.
    Zou, G. B.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 102 : 349 - 363
  • [7] Protection scheme for high-voltage direct-current transmission lines based on transient AC current
    Liu, Jian
    Tai, Nengling
    Fan, Chunju
    Huang, Wentao
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (16) : 2633 - 2643
  • [8] Pilot protection for flexible HVDC transmission lines based on transient voltage ratio characteristics
    Wang, Zhijie
    Li, Haifeng
    Jin, Haotian
    Liu, Hainan
    Liang, Yuansheng
    Wang, Gang
    International Journal of Electrical Power and Energy Systems, 2024, 162
  • [9] The Non-unit Transient-based Underreach Protection for EHV Transmission Lines
    Wu Y.
    Li Z.
    Xiao S.
    Huang Z.
    Li Z.
    Wei F.
    Lin X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 : 70 - 81
  • [10] Study of Non-Unit Transient-Based Protection for HVDC Transmission Lines
    You Min
    Zhang Bao-hui
    Cao Rui-feng
    Xu Jing-dong
    Zhang Song
    Bo Zhi-qian
    Klimek, Andrew
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3303 - +