Design and Fabrication Considerations, Numerical Modelling, and Testing of a MEMS Microgripper<bold> </bold>

被引:0
|
作者
Cauchi, Marija [1 ]
Mollicone, Pierluigi [1 ]
Mallia, Bertram [2 ]
Grech, Ivan [3 ]
Portelli, Barnaby [3 ]
Sammut, Nicholas [3 ]
机构
[1] Univ Malta, Fac Engn, Dept Mech Engn, Msida, Malta
[2] Univ Malta, Fac Engn, Dept Met & Mat Engn, Msida, Malta
[3] Univ Malta, Fac Informat & Commun Technol, Dept Microelect & Nanoelect, Msida, Malta
关键词
microgripper; electrothermal actuation; red blood cells; fabrication; PolyMUMPs (TM); buckling; fracture; residual stresses; stiction; VISCOELASTIC CHARACTERIZATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microgrippers play an important role in the manipulation of biological cells and tissues. This paper presents a horizontal electrothermally actuated microgripper that is designed for the handling and deformability characterisation of human red blood cells (RBCs). Pathological alterations in the mechanical properties of RBCs have been associated with a number of specific diseases. This has accentuated the significance of analysing the deformability characteristics of RBCs within the biomedical field. A polysilicon microgripper structure was designed and fabricated according to the dimensional specifications imposed by the commercial PolyMUMPs (TM) fabrication process. The microgripper design was developed and numerically modelled using finite element analysis where coupled electrothermomechanical simulations were carried out in CoventorWare (R). The fabrication method is presented in this paper, together with details of the experimental set-up used for the actuation testing. The tip displacement of the microgripper arm when electrothermally actuated is compared with that obtained by means of numerical simulations. Results show that the microgripper arm deflected as designed when electrothermally actuated, with good agreement obtained between simulation and experimental results. This paper also proposes critical design and fabrication considerations that were implied from the experimental campaign performed in this work and that take into account out-of-plane buckling of the hot arm, fracture of the arms in the vicinity of the anchored probe pads, residual stresses, and device stiction. Such considerations are regarded as an important outcome of this work, and they must be thoroughly investigated to mitigate the malfunction or failure of the microgripper.<bold> </bold>
引用
收藏
页数:6
相关论文
共 50 条
  • [1] <bold>Design and Fabrication of a MEMS-based Multi-Sensor</bold>
    Eun, Duk-Soo
    Kong, Dae-Young
    Yoo, Hyun-Jun
    Hong, Young-Myong
    Jang, Jong-Min
    Kang, Tae-Wook
    Yu, In-Sik
    Lee, Jong-Hyun
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 589 - +
  • [2] Essential design and fabrication considerations for the reliable performance of an electrothermal MEMS microgripper
    Marija Cauchi
    Ivan Grech
    Bertram Mallia
    Pierluigi Mollicone
    Barnaby Portelli
    Nicholas Sammut
    Microsystem Technologies, 2022, 28 : 1435 - 1450
  • [3] Essential design and fabrication considerations for the reliable performance of an electrothermal MEMS microgripper
    Cauchi, Marija
    Grech, Ivan
    Mallia, Bertram
    Mollicone, Pierluigi
    Portelli, Barnaby
    Sammut, Nicholas
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2022, 28 (06): : 1435 - 1450
  • [4] <bold>Design of Site Specific Delivery Capsule based on MEMS</bold>
    Liu Hongying
    Pi Xitian
    Zhou Chengwen
    Zheng Xiaolin
    Hou Whensheng
    Wen Zhiyu
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 501 - 501
  • [5] Experimental Evaluation and Numerical Modelling Residual Stresses in Glass Panel<bold> </bold>
    Majak, Juri
    Anton, Johan
    Ounapuu, Erko
    Auriemma, Fabio
    Pohlak, Meelis
    Eerme, Martin
    Klauson, Aleksander
    2018 INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE AND MANUFACTURING ENGINEERING (MSME 2018), 2019, 253
  • [6] Design, Fabrication, and Testing of an MEMS Microgripper With Dual-Axis Force Sensor
    Xu, Qingsong
    IEEE SENSORS JOURNAL, 2015, 15 (10) : 6017 - 6026
  • [7] Dynamic fault injection for system level simulation of MEMS - a design method for functional safety<bold> </bold>
    Blochmann, Tino
    Gerth, Stephan
    Markwirth, Thomas
    Schneider, Peter
    Jancke, Roland
    2018 SYMPOSIUM ON DESIGN, TEST, INTEGRATION & PACKAGING OF MEMS AND MOEMS (DTIP), 2018,
  • [8] On the Modelling and Placement of Bonding-pillar Holes in Multi-wafer, Vacuum-packaged MEMS<bold> </bold>
    Bojesomo, Alabi
    Syed, Wajih
    Elfadel, Ibrahim M.
    2018 SYMPOSIUM ON DESIGN, TEST, INTEGRATION & PACKAGING OF MEMS AND MOEMS (DTIP), 2018,
  • [9] Design, fabrication and testing of a 2 DOF compliant flexural microgripper
    Royson Donate Dsouza
    Karanth P. Navin
    Theo Theodoridis
    Priyaranjan Sharma
    Microsystem Technologies, 2018, 24 : 3867 - 3883
  • [10] Design, fabrication and testing of a 2 DOF compliant flexural microgripper
    Dsouza, Royson Donate
    Navin, Karanth P.
    Theodoridis, Theo
    Sharma, Priyaranjan
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (09): : 3867 - 3883