Performance studies of hybrid solid desiccant-vapor compression air-conditioning system for hot and humid climates

被引:83
|
作者
Jani, D. B. [1 ]
Mishra, Manish [1 ]
Sahoo, P. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttar Pradesh, India
关键词
COP; Desiccant cooling system; Regeneration temperature; TRNSYS; COOLING SYSTEM; DEHUMIDIFICATION; COMPONENTS; WHEEL;
D O I
10.1016/j.enbuild.2015.05.055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Suitability of the solid desiccant cooling to supplement the conventional vapor compression refrigeration air conditioner has been studied for typical hot and humid climate. A solid desiccant and vapor compression hybrid air-conditioning system for a test room of cooling capacity 1.8 kW, has been modelled in simulation studio project and simulated in TRNSYS environment for the cooling season from March to September. The obtained results have been validated against experimental test data. The effects of ambient humidity ratio and temperature on coefficient of performance and supply air temperature have been evaluated. The variation in coefficient of performance has been obtained at various regeneration temperatures. The simulation results show the suitability of such systems for cooling of building in hot and humid climates. (c) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:284 / 292
页数:9
相关论文
共 50 条
  • [1] Experimental investigation on solid desiccant-vapor compression hybrid air-conditioning system in hot and humid weather
    Jani, D. B.
    Mishra, Manish
    Sahoo, P. K.
    [J]. APPLIED THERMAL ENGINEERING, 2016, 104 : 556 - 564
  • [2] Performance study on a hybrid solid desiccant-vapor compression air-conditioning system for hot-humid ambient conditions
    Venkatesh, R.
    Ganesh, Madhu
    Rudramoorthy, R.
    [J]. HEAT TRANSFER, 2024, : 507 - 529
  • [3] Performance analysis of hybrid solid desiccant-vapor compression air conditioning system in hot and humid weather of India
    Jani, D. B.
    Mishra, Manish
    Sahoo, P. K.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (05): : 523 - 538
  • [4] Performance analysis of a novel liquid desiccant-vapor compression hybrid air-conditioning system
    Li Yinglin
    Zhang Xiaosong
    Tan Laizai
    Zhang Zhongbin
    Wu Wei
    Xia Xueying
    [J]. ENERGY, 2016, 109 : 180 - 189
  • [5] Parametric studies on coupled columns of liquid desiccant-vapor compression hybrid air conditioning system
    Mohan, B. Shaji
    Tiwari, Shaligram
    Maiya, M. P.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2012, 7 (02) : 149 - 158
  • [6] Performance prediction of solid desiccant - Vapor compression hybrid air-conditioning system using artificial neural network
    Jani, D. B.
    Mishra, Manish
    Sahoo, P. K.
    [J]. ENERGY, 2016, 103 : 618 - 629
  • [7] Optimization of air-conditioning system operating strategies for hot and humid climates
    Huh, Jung-Ho
    Brandemuehl, Michael J.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (07) : 1202 - 1213
  • [8] Experimental investigations on performance of liquid desiccant-vapor compression hybrid air conditioner
    Mohan, B. Shaji
    Tiwari, Shaligram
    Maiya, M. P.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 77 : 153 - 162
  • [9] Studies on solid desiccant based hybrid air-conditioning systems
    Dhar, PL
    Singh, SK
    [J]. APPLIED THERMAL ENGINEERING, 2001, 21 (02) : 119 - 134
  • [10] Performance analysis of hybrid solid desiccant - vapor compression air conditioning system: Application and comparative study
    Belguith, Sarra
    ben Slama, Romdhan
    Chaouachi, Bechir
    Meddeb, Zina
    [J]. 2020 11TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2020,