An L-cysteic acid-modified screen-printed carbon electrode for methyl parathion determination

被引:4
|
作者
Majer, David [1 ]
Finsgar, Matjaz [1 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Smetanova ul 17, Maribor 2000, Slovenia
关键词
Methyl parathion; L-Cysteic acid; Square-wave adsorptive stripping voltammetry; EIS; SPCE; ToF-SIMS; REDUCED GRAPHENE OXIDE; ELECTROCHEMICAL SENSOR; VOLTAMMETRIC DETERMINATION; GOLD NANOPARTICLES; ORGANOPHOSPHATE PESTICIDES; SENSITIVE DETECTION; URIC-ACID; NANOTUBES;
D O I
10.1016/j.microc.2022.108098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work demonstrates the development and validation of a non-enzymatic sensor consisting of an L-cysteic acid-modified screen-printed carbon electrode (LCA-SPCE) sensor for the determination of the hazardous organophosphorus pesticide methyl parathion (MP) using square-wave adsorptive stripping voltammetry (SWAdSV). The surface of LCA-SPCE was investigated using time of flight secondary ion mass spectrometry to confirm successful preparation of the LCA surface layer. In order to obtain the highest electrochemical response, the accumulation time and pH of the 0.1 M phosphate buffer solution (PBS) supporting electrolyte were opti-mized. Then, SWAdSV method validation was performed in 0.1 M PBS at pH 6.00, an accumulation potential at the open circuit potential, and an accumulation time of 120 s. Since an intensive background was observed from the measurement of blank solution on the LCA-SPCE, a background subtraction procedure was employed. Partial method validation of the LCA-SPCE sensor was performed by determining the limit of detection (LOD), the limit of quantification (LOQ), the linear concentration range, accuracy, and precision. The developed method has a very low LOD and LOQ of 2.5 mu g/L and 5.0 mu g/L, respectively, and a linear concentration range of 5.0-84.3 mu g/L (R2 = 0.9948). The average recovery and relative standard deviation were 109.6 % and 7.1 %, respectively (n = 6). This work also demonstrates the advantageous use of the multiple standard addition methodology compared to the calibration curve for analysing MP by means of an LCA-SPCE. Furthermore, electrochemical impedance spectroscopy was performed to show the differences between the bare-SPCE and LCA-SPCE. Finally, the appli-cation of the developed and validated LCA-SPCE sensor for the determination of MP was successfully employed for a real water sample (tap water), which showed the high accuracy and precision of the method. In addition, the interference and matrix effects were also studied.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Electrocatalytic oxidation and voltammetric determination of L-cysteic acid at the surface of p-bromanil modified carbon paste electrode
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Ramine, Maryam
    [J]. ELECTROANALYSIS, 2006, 18 (17) : 1722 - 1726
  • [2] Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
    Azimi, Hesameddin
    Sullivan, Connor
    Lu, Dingnan
    Brack, Eric
    Drew, Christopher
    Kurup, Pradeep
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 356 - 370
  • [3] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    M. S. Tiwari
    R. G. Thorat
    B. B. Popatkar
    V. V. Borge
    A. K. Kadu
    [J]. Analytical Sciences, 2023, 39 : 1889 - 1899
  • [4] Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
    Tiwari, M. S.
    Thorat, R. G.
    Popatkar, B. B.
    Borge, V. V.
    Kadu, A. K.
    [J]. ANALYTICAL SCIENCES, 2023, 39 (11) : 1889 - 1899
  • [5] Screen-Printed Carbon Electrode Modified with Poly-L-histidine Applied to Gold(III) Determination
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 100 - 106
  • [6] Graphene Oxide Nanoribbons Film Modified Screen-Printed Carbon Electrode for Real-Time Detection of Methyl Parathion in Food Samples
    Govindasamy, Mani
    Umamaheswari, Rajaji
    Chen, Shen-Ming
    Mani, Veerappan
    Su, Chaochin
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (09) : B403 - B408
  • [7] Electrochemical determination of tramadol using modified screen-printed electrode
    Mohammadi, Sayed Zia
    Jafari, Maedeh
    Jahani, Peyman Mohammadzadeh
    Ahmadi, Sayed Ali
    Mashayekh, Raana
    [J]. JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 127 - 135
  • [8] Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    Arrigan, DWM
    [J]. ELECTROANALYSIS, 2002, 14 (03) : 177 - 185
  • [9] Determination of isoniazid in human urine using screen-printed carbon electrode modified with poly-L-histidine
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    [J]. BIOELECTROCHEMISTRY, 2010, 77 (02) : 133 - 138
  • [10] SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACYANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
    Mattos, I. L.
    Padilla, F.
    Zagal, J. H.
    Falcao, E. H. L.
    Segura, R.
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (03): : 803 - 807