Utilization of intravenous immunoglobulin to ameliorate alloantibodies in a highly sensitized patient with a cardiac assist device awaiting heart transplantation - Fluorescence-activated cell sorter analysis

被引:40
|
作者
McIntyre, JA
Higgins, N
Britton, R
Faucett, S
Johnson, S
Beckman, D
Hormuth, D
Fehrenbacher, J
Halbrook, H
机构
[1] METHODIST HOSP,HISTOCOMPATIBIL LAB,INDIANAPOLIS,IN 46202
[2] METHODIST HOSP,DEPT TRANSPLANTAT,INDIANAPOLIS,IN 46202
关键词
D O I
10.1097/00007890-199609150-00027
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Surgery surrounding the use of mechanical assistance in cardiac transplant candidates often leads to multiple blood/platelet transfusions and subsequent development of alloantibodies. This is a case report of a 50-year-old male patient who had received blood transfusions during coronary bypass grafting 9 years earlier. He presented in acute and chronic heart failure and, despite therapy, became moribund with multisystem organ failure, His ejection fraction was 10%. A Novacor ventricular assist device was implanted on May 19, 1995 (day 0). The patient received 44 U of blood and 20 U of platelets, Although his percent reactive antibodies (PRA) were negative before surgery by fluorescence-activated cell sorter analysis, the PRA 3 days after implantation of the ventricular assist device was 80%; it increased to 100% by day 7. In an attempt to decrease the PRA, intravenous immunoglobulin was given at 3-week intervals. The PRA became negative and the patient received a donor heart that was negative by fluorescence-activated cell sorter cross-match on day 64. On days 69-72, a dramatic increase in alloantibody activity was promptly reversed with additional intravenous immunoglobulin. Currently at posttransplant month 12, the patient shows no humoral, cellular, or vascular evidence of rejection.
引用
收藏
页码:691 / 693
页数:3
相关论文
共 2 条
  • [1] Utilization of IVIG to ameliorate anti-HLA antibodies in a highly sensitized patient awaiting cardiac transplant with a Novacor cardiac assist device
    McIntyre, JA
    Higgins, N
    Britton, R
    Faucett, S
    Johnson, S
    Beckman, D
    Hormuth, D
    Fehrenbacher, J
    Halbrook, H
    [J]. HUMAN IMMUNOLOGY, 1996, 49 : 96 - 96
  • [2] Intravenous immunoglobulin reduces anti-HLA alloreactivity and shortens waiting time to cardiac transplantation in highly sensitized left ventricular assist device recipients
    John, R
    Lietz, K
    Burke, E
    Ankersmit, J
    Mancini, D
    Suciu-Foca, N
    Edwards, N
    Rose, E
    Oz, M
    Itescu, S
    [J]. CIRCULATION, 1999, 100 (19) : 229 - 235