Combination of Global Features for the Automatic Quality Assessment of Retinal Images

被引:4
|
作者
Jimenez-Garcia, Jorge [1 ]
Romero-Oraa, Roberto [1 ]
Garcia, Maria [1 ]
Lopez-Galvez, Maria I. [1 ,2 ,3 ]
Hornero, Roberto [1 ,4 ,5 ]
机构
[1] Univ Valladolid, Biomed Engn Grp, Paseo Belen 15, E-47011 Valladolid, Spain
[2] Hosp Clin Univ Valladolid, Dept Ophthalmol, Ave Ramon y Cajal 3, Valladolid 47003, Spain
[3] Univ Valladolid, Inst Oftalmobiol Aplicada, Paseo Belen 17, E-47011 Valladolid, Spain
[4] Univ Valladolid, Inst Invest Matemat IMUVA, E-47011 Valladolid, Spain
[5] Univ Salamanca, Inst Neurociencias Castilla & Leon INCYL, Salamanca 37007, Spain
关键词
diabetic retinopathy; fundus images; retinal image quality assessment; Shannon entropy; spectral entropy; continuous wavelet transform; multilayer perceptron; DIABETIC-RETINOPATHY; VESSEL SEGMENTATION; FEATURE-SELECTION; WAVELET; RELEVANCE; DIAGNOSIS; CLARITY;
D O I
10.3390/e21030311
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Diabetic retinopathy (DR) is one of the most common causes of visual loss in developed countries. Computer-aided diagnosis systems aimed at detecting DR can reduce the workload of ophthalmologists in screening programs. Nevertheless, a large number of retinal images cannot be analyzed by physicians and automatic methods due to poor quality. Automatic retinal image quality assessment (RIQA) is needed before image analysis. The purpose of this study was to combine novel generic quality features to develop a RIQA method. Several features were calculated from retinal images to achieve this goal. Features derived from the spatial and spectral entropy-based quality (SSEQ) and the natural images quality evaluator (NIQE) methods were extracted. They were combined with novel sharpness and luminosity measures based on the continuous wavelet transform (CWT) and the hue saturation value (HSV) color model, respectively. A subset of non-redundant features was selected using the fast correlation-based filter (FCBF) method. Subsequently, a multilayer perceptron (MLP) neural network was used to obtain the quality of images from the selected features. Classification results achieved 91.46% accuracy, 92.04% sensitivity, and 87.92% specificity. Results suggest that the proposed RIQA method could be applied in a more general computer-aided diagnosis system aimed at detecting a variety of retinal pathologies such as DR and age-related macular degeneration.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Objective Quality Assessment of Retinal Images Based on Texture Features
    Remeseiro, Beatriz
    Mendonca, Ana Maria
    Campilho, Aurelio
    [J]. 2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 4520 - 4527
  • [2] Assessment of image quality on color fundus retinal images using the automatic retinal image analysis
    Chuying Shi
    Jack Lee
    Gechun Wang
    Xinyan Dou
    Fei Yuan
    Benny Zee
    [J]. Scientific Reports, 12
  • [3] Assessment of image quality on color fundus retinal images using the automatic retinal image analysis
    Shi, Chuying
    Lee, Jack
    Wang, Gechun
    Dou, Xinyan
    Yuan, Fei
    Zee, Benny
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Automatic No-Reference Quality Assessment for Retinal Fundus Images Using Vessel Segmentation
    Koehler, Thomas
    Budai, Attila
    Kraus, Martin F.
    Odstrcilik, Jan
    Michelson, Georg
    Hornegger, Joachim
    [J]. 2013 IEEE 26TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2013, : 95 - 100
  • [5] Blind quality assessment for screen content images by combining local and global features
    Wu, Jun
    Xia, Zhaoqiang
    Zhang, Huiqing
    Li, Huifang
    [J]. DIGITAL SIGNAL PROCESSING, 2019, 91 : 31 - 40
  • [6] Automatic retinal image quality assessment and enhancement
    Lee, SC
    Wang, YM
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 1581 - 1590
  • [7] SUBJECTIVE QUALITY ASSESSMENT OF ENHANCED RETINAL IMAGES
    Yue, Guanghui
    Zhang, Shaoping
    Li, Yuan
    Zhou, Xiaoyan
    Zhou, Tianwei
    Zhou, Wei
    [J]. 2023 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP, 2023, : 3005 - 3009
  • [8] Automatic extraction of retinal features from colour retinal images for glaucoma diagnosis: A review
    Haleem, Muhammad Salman
    Han, Liangxiu
    van Hemert, Jano
    Li, Baihua
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2013, 37 (7-8) : 581 - 596
  • [9] Towards automatic quality assessment of range images
    Rodrigues, MA
    [J]. PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INTELLIGENT CONTROL, 2002, : 696 - 701
  • [10] Automatic quality assessment for fluorescence microscopy images
    Paul, Perrine
    Kalamatianos, Dimitrios
    Duessmann, Heiko
    Huber, Heinrich
    [J]. 8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 91 - +