Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery

被引:5
|
作者
Passo, Ross M. [1 ]
Hoskins, Zachary B. [1 ]
Tran, Khoa D. [2 ]
Patzer, Corrina [2 ]
Edmunds, Beth [1 ]
Morrison, John C. [1 ]
Parikh, Mansi [1 ]
Takusagawa, Hana L. [1 ]
Tehrani, Shandiz [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Ophthalmol, Casey Eye Inst, Portland, OR 97201 USA
[2] Lions VisionGift, Portland, OR USA
关键词
Corneal patch graft; Glaucoma drainage device (GDD); Graft erosion; Scleral patch graft; Tube exposure; TUBE; INACTIVATION; COVERAGE; OUTCOMES; VIRUSES;
D O I
10.1007/s40123-019-0190-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction Patch graft erosion and implant exposure is a known complication of glaucoma drainage device (GDD) surgery. Recently, electron beam (e-beam) irradiated corneal tissue has become available; however, limited data exist on the rates of erosion for e-beam irradiated corneal grafts compared to traditional scleral grafts after GDD surgery. Methods This retrospective study examines the records of 253 eyes from 225 adult subjects who underwent GDD surgery with either e-beam irradiated corneal or scleral grafts at the Casey Eye Institute by five surgeons between April 22, 2014 and October 11, 2017. Surgical procedures and the occurrence of graft erosion were determined using billing codes and verified by manual review of electronic health records. Results The average age at the time of surgery was 61.3 +/- 17.5 years (n = 200) and 60.8 +/- 16.8 years (n = 53) for the e-beam irradiated cornea and sclera groups, respectively. The average follow-up time post-surgery was 416 +/- 345 days and 495 +/- 343 days for the e-beam irradiated cornea and sclera groups, respectively. There were no statistically significant differences in sex, age, follow-up time, and glaucoma diagnosis between the groups; however, the e-beam irradiated cornea group was statistically more likely to have an Ahmed implant as compared to the sclera group. No erosion events were noted in either group. Conclusion e-Beam irradiated corneal grafts were used 3.8 times more frequently relative to scleral grafts, yet there were no cases of graft erosion in either group during the follow-up period.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 25 条
  • [1] Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery
    Ross M. Passo
    Zachary B. Hoskins
    Khoa D. Tran
    Corrina Patzer
    Beth Edmunds
    John C. Morrison
    Mansi Parikh
    Hana L. Takusagawa
    Shandiz Tehrani
    [J]. Ophthalmology and Therapy, 2019, 8 : 421 - 426
  • [2] Electron-beam irradiated corneal (halo™) versus scleral patch graft erosion rates in glaucoma drainage device surgery
    Passo, Ross
    Hoskins, Zachary
    Tran, Khoa D.
    Patzer, Corrina
    Tehrani, Shandiz
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery
    de Luna, Regina A.
    Moledina, Ameera
    Wang, Jiangxia
    Jampel, Henry D.
    [J]. JAMA OPHTHALMOLOGY, 2017, 135 (09) : 941 - 946
  • [4] The Intraoperative Impression and Postoperative Outcomes of Gamma-Irradiated Corneas in Corneal and Glaucoma Patch Surgery
    Daoud, Yassine J.
    Smith, Ronald
    Smith, Tessie
    Akpek, Esen K.
    Ward, Donald E.
    Stark, Walter J.
    [J]. CORNEA, 2011, 30 (12) : 1387 - 1391
  • [5] Gamma-irradiated Cornea Allograft for Glaucoma Surgery
    Lawrence, Scott D.
    Netland, Peter A.
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (05) : 355 - 357
  • [6] Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery
    Yu, Jea H.
    Nguyen, Chuck
    Gallemore, Esmeralda
    Gallemore, Ron P.
    [J]. CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2016, 2016
  • [7] Autologous Partial-thickness Scleral Flap and Donor Corneal Graft in Management of Tube Erosion of Glaucoma Drainage Device
    Liu, Xiongfei
    Law, Simon K.
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (04) : 347 - 351
  • [8] Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study
    Pan, Q.
    Jampel, H. D.
    Ramulu, P.
    Schwartz, G. F.
    Cotter, F.
    Cute, D.
    Daoud, Y. J.
    Murakami, P.
    Stark, W. J.
    [J]. EYE, 2017, 31 (03) : 430 - 436
  • [9] Clinical outcomes of gamma-irradiated sterile cornea in aqueous drainage device surgery: a multicenter retrospective study
    Q Pan
    H D Jampel
    P Ramulu
    G F Schwartz
    F Cotter
    D Cute
    Y J Daoud
    P Murakami
    W J Stark
    [J]. Eye, 2017, 31 : 430 - 436
  • [10] Tube erosion following insertion of a glaucoma drainage device with a pericardial patch graft
    Lama, PJ
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (09) : 1243 - 1244