LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

被引:11
|
作者
Baek, Won-Pil [1 ]
Kim, Yeon-Sik [1 ]
Choi, Ki-Yong [1 ]
机构
[1] Korea Atom Energy Res Inst, Thermal Hydraul Safety Res Div, Taejon 305353, South Korea
关键词
ATLAS; APR1400; OPR1000; Direct Vessel Injection; Integral Effect Test;
D O I
10.5516/NET.2009.41.6.775
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper summarizes the tests performed in the ATLAS facility during its first two years of operation (2007-2008). Two categories of tests have been performed successfully: (a) the reflood phase of the large-break loss-of-coolant accidents in a cold leg, and (b) the breaks in one of four direct vessel injection lines. Those tests contributed to understanding the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing an evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Several important and interesting phenomena have been observed during the tests. In most cases, the ATLAS shows reasonable accident characteristics and conservative results compared with those predicted by one-dimensional safety analysis codes. A wide variety of small-break LOCA tests will be performed in 2009.
引用
收藏
页码:775 / 784
页数:10
相关论文
共 50 条
  • [1] TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY
    Veronese, Fabio
    Kozlowsk, Tomasz
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (07) : 719 - 726
  • [2] Major findings from LBLOCA reflood tests using the ATLAS facility
    Park, Hyun-Sik
    Choi, Ki-Yong
    Cho, Seok
    Kang, Kyoung-Ho
    Choi, Nam-Hyun
    Kim, Yeon-Sik
    Baek, Won-Pil
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (12) : 3920 - 3929
  • [3] The characteristics of break flows of SBLOCA tests in ATLAS facility
    Kim, Yeon-Sik
    Park, Hyun-Sik
    Cho, Seok
    Choi, Ki-Yong
    ANNALS OF NUCLEAR ENERGY, 2015, 85 : 1200 - 1209
  • [4] Comparison of integral thermal-hydraulic behaviors of a DVI line break SBLOCA with an equivalent cold leg break
    Choi, Ki-Yong
    Cho, Seok
    Kang, Kyoung-Ho
    Park, Hyun-Sik
    Kim, Yeon-Sik
    NUCLEAR ENGINEERING AND DESIGN, 2014, 273 : 421 - 434
  • [5] Counterpart Tests of SBLOCA on the Effect of Break Location with the ATLAS: DVI Nozzle versus Cold-Leg Breaks
    Park, Hyun-Sik
    Choi, Ki-Yong
    Cho, Seok
    Kang, Kyoung-Ho
    Kim, Yeon-Sik
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2011, 48 (10) : 1319 - 1326
  • [6] An integral loop test and MARS code analysis for a DVI line break LOCA in the APR1400
    Lee, Keo Hyoung
    Bae, Byoung Uhn
    Kim, Yong Soo
    Yun, Byong Jo
    Chun, Ji Han
    Park, Goon Cherl
    NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (12) : 3336 - 3347
  • [7] Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility
    Bae, Byoung-Uhn
    Lee, Jae Bong
    Park, Yu-Sun
    Kim, Jongrok
    Kang, Kyoung-Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (08) : 2477 - 2487
  • [8] An analytical investigation of direct vessel injection line break accidents of the ATLAS facility
    Kim, Yeon-Sik
    Choi, Ki-Yong
    ANNALS OF NUCLEAR ENERGY, 2015, 83 : 398 - 407
  • [9] Integral behavior of the ATLAS facility for a 3-inch small break loss of coolant accident
    Choi, Ki-Yong
    Park, Hyun-Sik
    Cho, Seok
    Euh, Dong-Jin
    Kim, Yeon-Sik
    Baek, Won-Pil
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2008, 40 (03) : 199 - 212
  • [10] Integral Effect Test on Top-Slot Break Scenario With 4 Inches Cold Leg Break LOCA in ATLAS Facility
    Kim, Jongrok
    Bae, Byoung-Uhn
    Lee, Jae Bong
    Park, Yusun
    Cho, Seok
    Kang, Kyoung-Ho
    FRONTIERS IN ENERGY RESEARCH, 2020, 8