Numerical Characterization of Dosimetry, Human Body Resistance and Heart Current Resulting from Power-Frequency Touch Current for an Anatomically Realistic Human Model

被引:2
|
作者
Hayashi, Noriyuki [1 ]
Tarao, Hiroo [2 ]
Isaka, Katsuo [3 ]
机构
[1] Kyushu Univ, Elect Engn Labs, Fac Engn Sci, Dept Appl Sci Elect & Mat, Kasuga, Fukuoka 8168580, Japan
[2] Takamatsu Natl Coll Technol, Dept Elect & Comp Engn, Takamatsu, Kagawa 7618058, Japan
[3] Univ Tokushima, Dept Elect & Elect Engn, Fac Engn, Tokushima 7708506, Japan
关键词
body resistance; dosimetry; heart current; low frequency; realistic human model; SPFD; touch current; RESOLUTION ORGAN DOSIMETRY; HUMAN EXPOSURE; CONTACT;
D O I
10.1002/tee.20439
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Characteristics of power-frequency touch Current inside an anatomically realistic human model of Japanese adult werenumerically analyzed under various scenarios of Current paths using a modified scalar potential finite difference (SPFD) method. Then, complex distributions of the current density in the model were visually illustrated. Results of the dosimetry Of Current density for excitable tissues indicates that the touch current within the reference level (0.5 mA) does not always satisfy the basic restriction Of Current density in the light of ICNIRP guideline for general public. Two sets of the internal body resistances R-i (i.e., 1130-1510 Omega and 1460-1920 Omega) are obtained, depending on the conductivity sets used. Although R-i considerably depends on the current scenario concerned, the highest values of R-i were obtained for the hand-to-hand scenario, regardless of the conductivity set. The inhomogeneous model always gives a higher value of R-i than does the homogeneous model that has a single conductivity equivalent to the weighted-average conductivity of the inhomogeneous model. It is found that the conductivity Of muscle has significant influence on R-i, and that the resistance around the wrist and ankle is one of the predominant parameters to decide R-i. It is clearly shown that the current scenarios affect the pattern of the heart Current flow, especially the direction of it. to a large extent. It is found that a current of 34-40% of touch current flows into the heart, and then the heart-current ratio is remarkably larger than old data. The heart-current factors of around 0.85 obtained are almost independent of the current scenarios, unlike those indicated in IEC60479-1, provided that the direction of heart current is ignored. (C) 2009 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
引用
收藏
页码:523 / 533
页数:11
相关论文
共 22 条
  • [1] Heart Current in an Anatomically Realistic Human Model due to Contact with a Low-Frequency Energized Source
    Tarao, Hiroo
    Hayashi, Noriyuki
    Isaka, Katsuo
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2009, 4 (02) : 306 - 308
  • [2] Calculation of Human Body Resistance at Power Frequency Using Anatomic Numerical Human Model
    Aga, Katsuaki
    Tarao, Hiroo
    Urushihara, Shiro
    [J]. COE ON SUSTAINABLE ENERGY SYSTEM (THAI-JAPAN), 2016, 89 : 401 - 407
  • [3] Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body
    Dimbylow, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02): : 221 - 230
  • [4] Current densities in a 2 mm resolution anatomically realistic model of the body induced by low frequency electric fields
    Dimbylow, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04): : 1013 - 1022
  • [5] Influence and Correction from the Human Body on the Measurement of a Power-Frequency Electric Field Sensor
    Xiao, Dongping
    Liu, Huaitong
    Zhou, Qiang
    Xie, Yutong
    Ma, Qichao
    [J]. SENSORS, 2016, 16 (06):
  • [6] Numerical Simulation of Heart-Current Factors and Electrical Models of the Human Body
    Freschi, Fabio
    Guerrisi, Alessandra
    Tartaglia, Michele
    Mitolo, Massimo
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (05)
  • [7] Numerical simulation of heart-current factors and electrical models of the human body
    Freschi, Fabio
    Guerrisi, Alessandra
    Tartaglia, Michele
    Mitolo, Massimo
    [J]. 2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,
  • [8] Measurements of resistance of the human body and its dependence on the current in a wide frequency area
    Malov, NN
    [J]. COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1936, 10 : 227 - 230
  • [9] BIOMAGNETIC LOCALIZATION OF ELECTRICAL-CURRENT SOURCES IN THE HUMAN HEART WITH REALISTIC VOLUME CONDUCTORS USING THE SINGLE-CURRENT-DIPOLE MODEL
    BRUDER, H
    KILLMANN, R
    MOSHAGE, W
    WEISMULLER, P
    ACHENBACH, S
    BOMMEL, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (04): : 655 - 668
  • [10] FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz
    Dimbylow, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03): : 479 - 490