Biomechanical assessment of a novel bone lengthening plate system - A cadaveric study

被引:0
|
作者
Jung, Tae Gon [1 ]
Suh, Seung Woo [2 ]
Lee, Sung Jae [3 ]
Kim, Bongju [4 ]
Han, Dong-Wook [1 ]
Yang, Jae Hyuk [2 ]
机构
[1] Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Nanomed Engn, Pusan 609735, South Korea
[2] Korea Univ, Guro Hosp, Dept Orthoped, Scoliosis Res Inst, Seoul 152703, South Korea
[3] Inje Univ, Dept Biomed Engn, Gimhae Si 621749, Gyungnam, South Korea
[4] Kyoto Univ, Grad Sch Med, Ctr Innovat Immunoregulat Technol & Therapeut, Sakyo Ku, Kyoto 6068501, Japan
关键词
Femur; Biomechanical stability; Bone lengthening plate; Bone mineral density; LOCKING COMPRESSION PLATE; EXTERNAL FIXATORS; MECHANICAL PERFORMANCE; ILIZAROV TECHNIQUE; FIXATION; HYBRID; OSTEOSYNTHESIS; CORROSION; FRACTURE; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2012.11.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Although many types of external fixators have been developed for distraction osteogenesis, all have some drawbacks. We recently developed a novel bone lengthening plate to overcome these problems. The purpose of this study is to conduct biomechanical analyses using cadavers to assess the stability of the bone lengthening plate in relation to distraction length and femoral bone mineral density. Methods: We used human cadaveric femurs (n=18) to assess the effects of distraction length and bone mineral density on the biomechanical stability of the bone lengthening plate. After establishing control (n = 6, 0 mm lengthening) and experimental groups (n = 12, 30 mm lengthening), we measured biomechanical stability (structural stiffness, ultimate load, and displacement) under a compressive load. The experimental group was subdivided into a group with normal bone mineral density (n=6) and a group with osteoporosis (n=6), and the biomechanical stability of these groups was compared. Finding: Structural stiffness differed significantly between the control (417.6 N/mm) and combined experimental groups (185.6 N/mm, p = 0.002). Ultimate load also differed significantly between the control (1327.8 N) and combined experimental (331.4 N, p = 0.002) groups. Bone mineral density was unrelated to structural stiffness (p=0.204), ultimate load (0.876), or displacement (0.344). In all cases, failure of the bone lengthening plate occurred at the longitudinal connectors, such as the connecting columns between the upper and lower plates, and the lengthening shaft of the bone lengthening plate. Interpretation: The biomechanical stability of the bone lengthening plate was affected by the lengthening length but not by bone mineral density. In addition, biomechanical stability during lengthening was most strongly influenced by the longitudinal connectors. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [1] Biomechanical assessment of a novel lengthening plate for distraction osteogenesis: A finite element study
    Woo S.-H.
    Suh S.W.
    Jung T.G.
    Lee S.-J.
    Han D.-W.
    Yang J.H.
    Biomedical Engineering Letters, 2016, 6 (4) : 216 - 223
  • [2] Passive Eversion Assessment for Progressive Collapsing Foot Deformity After Lateral Column Lengthening A Cadaveric Biomechanical Study
    Kim, Jaeyoung
    Hoffman, Jeffrey W.
    Ellis, Scott J.
    Deland, Jonathan T.
    Steineman, Brett D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2024, 106 (10): : 906 - 911
  • [3] Cadaveric biomechanical assessment of different configurations for a novel pin and plate fixation method in distal humerus fractures
    Same, Kaveh
    Hakiminejad, Alireza
    Nourani, Amir
    Nabian, Mohammad Hossein
    Foruozesh, Mehdi
    Kamrani, Reza Shahriar
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [4] Cadaveric biomechanical assessment of different configurations for a novel pin and plate fixation method in distal humerus fractures
    Kaveh Same
    Alireza Hakiminejad
    Amir Nourani
    Mohammad Hossein Nabian
    Mehdi Foruozesh
    Reza Shahriar Kamrani
    Scientific Reports, 14
  • [5] Biomechanical Evaluation of an Anterior Upper Thoracic Plate Fixation System: An In Vitro Human Cadaveric Study
    Xiong, Chunxiang
    Luo, Juli
    Yin, Dong
    Zhan, Xinli
    Liu, Huijiang
    WORLD NEUROSURGERY, 2019, 124 : E503 - E509
  • [6] Biomechanical testing of cadaveric specimens: Importance of bone mineral density assessment
    Ambrose, CG
    Kiebzak, GM
    Sabonghy, EP
    Tabor, OB
    Peindl, RD
    Clanton, TO
    Anderson, RA
    Davis, WH
    FOOT & ANKLE INTERNATIONAL, 2002, 23 (09) : 850 - 855
  • [7] Biomechanical analysis of a magnesium plantar plate prototype system for the first tarsometatarsal joint fusion: a cadaveric study
    Zhou, Peng
    Ribeiro, Marx
    Greven, Johannes
    Praster, Maximilian
    Seitz, Jan-Marten
    Habicht, Simon
    Hildebrand, Frank
    Balmayor, Elizabeth R.
    Lichte, Philipp
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [8] Biomechanical Evaluation of Hybrid Bicortical and Unicortical Screw and Bone Plate Fixation in Humeral Mid-Shaft Fractures: A Study on Cadaveric Bone
    Trung Le
    McDeed, Benjamin
    Ha Van Vo
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 499 - 502
  • [9] Biomechanical Evaluation of a Cadaveric Flatfoot Model and Lateral Column Lengthening Technique
    Heckmann, Nathanael D.
    Mercer, Jeffrey N.
    Wang, Lawrence C.
    McGarry, Michelle H.
    Ross, Steven D. K.
    Lee, Thay Q.
    JOURNAL OF FOOT & ANKLE SURGERY, 2021, 60 (05): : 956 - 959
  • [10] A comparative biomechanical study of a novel integrated plate spacer for stabilization of cervical spine: An in vitro human cadaveric model
    Majid, Kamran
    Chinthakunta, Suresh
    Muzumdar, Aditya
    Khalil, Saif
    CLINICAL BIOMECHANICS, 2012, 27 (06) : 532 - 536