PEAK POWER OUTPUT TEST ON A ROWING ERGOMETER: A METHODOLOGICAL STUDY

被引:14
|
作者
Metikos, Boris [1 ]
Mikulic, Pavle [1 ]
Sarabon, Nejc [2 ]
Markovic, Goran [1 ]
机构
[1] Univ Zagreb, Sch Kinesiol, Motor Control & Human Performance Lab, Zagreb 41000, Croatia
[2] Univ Primorska, Andrej Marus Inst, Dept Hlth Study, Koper, Slovenia
关键词
muscle power; reliability; validity; measurement; VERTICAL JUMP TEST; MUSCLE POWER; MAXIMAL POWER; SPORTS-MEDICINE; RELIABILITY; PERFORMANCE; ROWERS; DETERMINANTS; VALIDITY;
D O I
10.1519/JSC.0000000000000944
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Metikos, B, Mikulic, P, Sarabon, N, and Markovic, G. Peak power output test on a rowing ergometer: A methodological study. J Strength Cond Res 29(10): 2919-2925, 2015We aimed to examine the reliability and validity of the peak power output test on a rowing ergometer (Concept II Model D Inc.) and to establish the optimal resistance at which this peak power output was observed in 87 participants with varying levels of physical activity and rowing expertise: 15 male and 12 female physically inactive students (age: 21 +/- 2 years), 16 male and 20 female physically active students (age: 23 +/- 2 years), and 15 male and 9 female trained rowers (age: 19 +/- 2 years). The participants performed countermovement jump (CMJ) test on a force plate, followed by 3 maximal-effort rowing trials using the lowest, medium, and the highest adjustable resistance settings (i.e., 1, 5, and 10 on the resistance control dial on the ergometer) in randomized order. The test proved to be reliable (coefficients of variation: 2.6-6.5%; intraclass correlation coefficients: 0.87-0.98). The correlation coefficients between CMJ peak power and rowing peak power (both in watts per kilogram) were fairly consistent across all 3 groups of participants and resistance levels, ranging between r = 0.70 and r = 0.78. Finally, the highest power output was observed at the highest resistance setting in 2 nonathletic groups (p < 0.01), whereas rowers seem to produce the highest power output at the moderate-resistance setting. We conclude that the power output test on a Concept II rowing ergometer may serve as a reliable and valid tool for assessing whole-body peak power output in untrained individuals and rowing athletes.
引用
收藏
页码:2919 / 2925
页数:7
相关论文
共 50 条
  • [1] Peak power output predicts rowing ergometer performance in elite male rowers
    Bourdin, M
    Messonnier, L
    Hager, JP
    Lacour, JR
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2004, 25 (05) : 368 - 373
  • [2] A mathematical model for power output in rowing on an ergometer
    Scott Gordon
    Sports Engineering, 2003, 6 (4) : 221 - 234
  • [3] Rowing skill affects power loss on a modified rowing ergometer
    Hofmijster, Mathijs J.
    Van Soest, A. J.
    De Koning, Jos J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (06): : 1101 - 1110
  • [4] COMPARISON OF THE MULTISTAGE TEST ON A ROWING ERGOMETER WITH ACTUAL ROWING IN A RACING SHELL
    LORMES, W
    STEINACKER, JM
    MICHALSKY, R
    GRUNERTFUCHS, M
    WODICK, RE
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1987, 8 (02) : 165 - 165
  • [5] A CONSTANT-LOAD ERGOMETER FOR MEASURING PEAK POWER OUTPUT AND FATIGUE
    WILLIAMS, JH
    BARNES, WS
    SIGNORILE, JF
    JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (05) : 2343 - 2348
  • [6] Development of a rowing ergometer protocol to test whole body VO2peak in McArdle disease
    Godfrey, R.
    Newbury, J.
    Chatfield, S.
    Pattni, J.
    Wakelin, A.
    Quinlivan, R.
    NEUROMUSCULAR DISORDERS, 2019, 29 : S83 - S84
  • [7] Validation of a 6 Second Cycle Test for the Determination of Peak Power Output (PPO) Using Wattbike Cycle Ergometer
    Herbert, Peter
    Sculthorpe, Nicholas
    Grace, Fergal
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 933 - 933
  • [8] Reproducibility of cycling at 110% peak power output: methodological concern
    Sabour, S.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2015, 55 (11): : 1416 - 1416
  • [9] A New Submaximal Rowing Test to Predict 2,000-m Rowing Ergometer Performance
    Otter, Ruby T. A.
    Brink, Michel S.
    Lamberts, Robert P.
    Lemmink, Koen A. P. M.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (09) : 2426 - 2433
  • [10] Reliable Peak Power Assessment During Concentric and Flexion-Extension-Cycle Based Rowing Strokes using a Non-Modified Rowing Ergometer
    Held, Steffen
    Rappelt, Ludwig
    Donath, Lars
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2022, 21 (01) : 131 - 136