摘要
The application of robust statistical methods to assess the precision (uncertainty) of the results of interlaboratory testing of measurement method is presented. These results may include outliers. An usual rejection of such data reduces the reliability of evaluation, especially for small samples. And the robust methods take into consideration all the sample data (also with outliers). The use of two robust methods are provided for international rules of comparative studies in accredited laboratories. However, there is a lack of instructions on how to proceed them in practice. Evaluation of the precision of results, using the same method for homogeneous objects in nine laboratories, was presented. By traditional calculations, the estimate of the standard deviation was 1.5 times higher without rejection of outlier in comparison to one with rejection of outlier. Then, after using the robust method "Algorithm S", the obtained value was near the lower of two mentioned above, and with greater reliability.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 50 条
  • [1] Interlaboratory Study and Precision Statement for AASHTO T 336 Test Method
    Gudimettla, Jagan M.
    Crawford, Gary L.
    Tanesi, Jussara
    Ardani, Ahmad A.
    TRANSPORTATION RESEARCH RECORD, 2015, (2508) : 13 - 21
  • [2] Interlaboratory assessment of measurement precision and bias in the coulometric Karl Fischer determination of water
    Margolis, SA
    Angelo, JB
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) : 505 - 512
  • [3] Interlaboratory assessment of measurement precision and bias in the coulometric Karl Fischer determination of water
    Sam A. Margolis
    Jacob B. Angelo
    Analytical and Bioanalytical Chemistry, 2002, 374 : 505 - 512
  • [4] FLEECE MEASUREMENT INTERLABORATORY TRIALS - AN ANALYSIS OF THE FACTORS INFLUENCING THE PRECISION OF TEST-RESULTS
    MORGAN, PD
    WOOL TECHNOLOGY AND SHEEP BREEDING, 1990, 38 (01): : 21 - 23
  • [5] Precision of the air void characteristics measurement by ASTM C 457: Results of an interlaboratory test program
    Saucier, F
    Pleau, R
    Vezina, D
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (05) : 1118 - 1128
  • [6] Precision of the air void characteristics measurement by ASTM C 457: results of an interlaboratory test program
    Universite Laval, Quebec, Canada
    Can J Civ Eng, 5 (1118-1128):
  • [7] INTERLABORATORY TEST FOR WOOL FINENESS USING PIMC PARTICLE MEASUREMENT COMPUTER SYSTEM
    POHLE, EM
    JOURNAL OF TESTING AND EVALUATION, 1975, 3 (03) : 159 - 162
  • [8] Precision measurement of nanobeam thickness using bending test
    Xu, Lin-Yan
    Li, Da-Chao
    Liu, Rui-Peng
    Fu, Xing
    Hu, Xiao-Tang
    Zhang, Wen-Dong
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (01): : 7 - 11
  • [9] A High-Precision Time Interval Measurement Method Using Phase-Estimation Algorithm
    Zhu, Xiangwei
    Sun, Guangfu
    Yong, Shaowei
    Zhuang, Zhaowen
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (11) : 2670 - 2676
  • [10] Robust watermarking method using a fast algorithm
    Chikouche, A
    Sweeney, P
    Vladimirova, T
    DIGITAL MEDIA: PROCESSING MULTIMEDIA INTERACTIVE SERVICES, 2003, : 259 - 264