Interferometric calibration of piezocapacitive displacement actuators

被引:0
|
作者
Sacconi, A
Picotto, GB
Pasin, W
机构
关键词
displacement; non-linearity; heterodyne interferometry;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A calibration set-up based on optical heterodyne interferometry with sub-nanometric resolution for displacement measurements is described. For minimising the effects of thermal drifts and periodic non-linearity of the interferometer, the optical path difference is changed in steps of integer lambda for a full scan loop of the actuator. Accurate h-steps are obtained by means of a computer-based loop control of the out-of-phase between the reference and the measuring signal of the apparatus. A combined standard uncertainty of about 0,7 nm + 0,7 . 10(-4) L was estimated for the measured displacements of the actuator, corrected by a quadratic polynomial fit. The actuator has then been used to test the non-linearity of the differential interferometer. A sinusoidal non-linearity of amplitude 1,5 nm and period h was observed with an optimised optical set-up.
引用
下载
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [1] Interferometric calibration of microdisplacement actuators
    Picotto, GB
    RECENT DEVELOPMENTS IN TRACEABLE DIMENSIONAL MEASUREMENTS II, 2003, 5190 : 355 - 360
  • [2] A facility for interferometric measurement of linear displacement in actuators and calibration of sensors at cryogenic temperatures between 4.2 K and 77 K
    Chave, RG
    Wiseman, TAJ
    Barmatz, MB
    Hahn, I
    ACTUATOR TECHNOLOGY AND APPLICATIONS, 1996, 2865 : 58 - 65
  • [3] Calibration of the LIGO displacement actuators via laser frequency modulation
    Goetz, E.
    Savage, R. L., Jr.
    CLASSICAL AND QUANTUM GRAVITY, 2010, 27 (21)
  • [4] Laser interferometric displacement measurements of multi-layer actuators and PZT ceramics
    Burianova, L
    Bowen, CR
    Prokopova, M
    Sulc, M
    FERROELECTRICS, 2005, 320 : 629 - 637
  • [5] Laser interferometric measurement of displacement-field characteristics of piezoelectric actuators and actuator materials
    Moilanen, H
    Leppävuori, S
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 92 (1-3) : 326 - 334
  • [6] Real-time calibration of open-loop piezoelectric actuators for interferometric applications
    Bruno L.
    Maletta C.
    International Journal of Mechanics and Materials in Design, 2008, 4 (2) : 97 - 103
  • [7] A novel calibration character study for micro-displacement actuators with segmented mirrors
    Zou, Yu-di
    Hui, Mei
    Du, Juan
    Yu, Fei
    Zhao, Yue-jin
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND OPTOELECTRONIC INSTRUMENTS, 2009, 7156
  • [8] INTERFEROMETRIC DISPLACEMENT INDICATION
    LAY, CW
    INSTRUMENTS & CONTROL SYSTEMS, 1970, 43 (05): : 110 - &
  • [9] Calibration of interferometric arrays
    ten Brummelaar, TA
    CATCHING THE PERFECT WAVE: ADAPTIVE OPTICS AND INTERFEROMETRY IN THE 21ST CENTURY, 1999, 174 : 147 - 158
  • [10] Enhanced optical coherence vibration tomography for subnanoscale-displacement-resolution calibration of piezoelectric actuators
    Zhong, Shuncong
    Zhang, Qiukun
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 233 : 42 - 46