Devices for percutaneous Access and Tissue Sampling in the Punch Biopsy

被引:0
|
作者
Fricke, A. [1 ]
Hauschild, K. [1 ]
Berger, M. [2 ]
Speicher, T. [2 ]
Heske, T. [3 ]
机构
[1] HTWsaar, Saarbrucken, Germany
[2] TU Chemnitz, Chemnitz, Germany
[3] Instrumente & Produkte GmbH, BIP Biomed, Turkenfeld, Germany
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Punch biopsy is an established procedure in minimally invasive medicine extracting human tissue samples for histological examinations to diagnose the presence or extent of carcinogenic tissue. Commonly used devices for performing punch biopsy consist of a twopart needle system which is injected into the target area at high speed. A detailed analysis of the procedure itself as well as the device with respect to its functional characteristics showed a high potential for improvement in terms of the benefits for the patient, the handling by the practicing surgeon and the economic constraints in the medical environment. In the framework of a publicly funded project, solutions were developed to optimize the procedure with regard to the accuracy of the needle system, the reduction in tissue trauma and the implementation of percutaneous access at reduced penetration force. Experiments with phantom tissues using a high-speed camera were conducted and a tissue needle simulation model using the MBD software RECURDYN were developed.
引用
收藏
页码:177 / 189
页数:13
相关论文
共 50 条
  • [1] PUNCH SAMPLING BIOPSY TECHNIQUE
    PALKOVITS, M
    METHODS IN ENZYMOLOGY, 1983, 103 : 368 - 376
  • [2] Assessing the suitability of a non-lethal biopsy punch for sampling fish muscle tissue
    Henderson, C. J.
    Stevens, T. F.
    Lee, S. Y.
    FISH PHYSIOLOGY AND BIOCHEMISTRY, 2016, 42 (06) : 1521 - 1526
  • [3] Punch biopsy or fine needle aspiration biopsy in percutaneous puncture
    Erlemann, R
    Zimmerschied, A
    Gilger, F
    Schroder, M
    RADIOLOGE, 1998, 38 (02): : 126 - 134
  • [4] Punch biopsy or fine needle aspiration biopsy in percutaneous puncture
    R. Erlemann
    A. Zimmerschied
    F. Gilger
    M. Schröder
    Der Radiologe, 1998, 38 : 126 - 134
  • [5] Assessing the suitability of a non-lethal biopsy punch for sampling fish muscle tissue
    C. J. Henderson
    T. F. Stevens
    S. Y. Lee
    Fish Physiology and Biochemistry, 2016, 42 : 1521 - 1526
  • [6] Surgical Pearl: Double-trephine punch biopsy technique for sampling subcutaneous tissue
    Ha, CT
    Nousari, HC
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2003, 48 (04) : 609 - 610
  • [7] PERCUTANEOUS PUNCH BIOPSY OF VERTEBRAL BODIES WITH JAMSHIDI NEEDLE
    WOHLENBERG, H
    LORBACHER, P
    DRECHSEL, U
    SCHMARSOW, R
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1978, 103 (21) : 902 - 904
  • [8] Percutaneous Core Biopsy Devices
    Strnad, Benjamin S.
    Kristeva, Mariya
    Itani, Malak
    Fetzer, David T.
    O'Connor, Stacy D.
    Patel, Maitray D.
    Middleton, William D.
    ULTRASOUND QUARTERLY, 2024, 40 (01) : 1 - 19
  • [9] A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans
    M Chondronikola
    P Annamalai
    T Chao
    C Porter
    M K Saraf
    F Cesani
    L S Sidossis
    International Journal of Obesity, 2015, 39 : 1561 - 1564
  • [10] A percutaneous needle biopsy technique for sampling the supraclavicular brown adipose tissue depot of humans
    Chondronikola, M.
    Annamalai, P.
    Chao, T.
    Porter, C.
    Saraf, M. K.
    Cesani, F.
    Sidossis, L. S.
    INTERNATIONAL JOURNAL OF OBESITY, 2015, 39 (10) : 1561 - 1564