PCB/toxaphene group separation on silica prior to congener specific determination of toxaphene residues in fish and other samples by GC/ECD

被引:38
|
作者
Krock, B
Vetter, W
Luckas, B
机构
[1] Inst. fur Ernahrung und Umwelt, Friedrich-Schiller-Univ. Jena, D-07743 Jena
关键词
D O I
10.1016/S0045-6535(97)00222-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A precise quantification of toxaphene residues of environmental samples by gas chromatography/electron capture detection (GC/ECD) requires the separation of the bulk of the polychlorinated biphenyls (PCBs) from the compounds of technical toxaphene (CTT) fraction. For this reason, a PCB/CTT group separation on silica was developed. B8-1413 (Parlar #26) and B7-515 (Parlar #32) eluted as first and last put often important CTT standards, and can be used to determine the elution volume of the CTT fraction on silica. GC/ECD quantification of CTTs was possible after separation of PCBs on 8.0 g activated silica eluted with 48 mL n-hexane followed by quantitative elution of CTTs with n-hexane/toluene (65:35; v/v). This method is a compromise between separation efficiency and consumption of material. Finally, eight CTTs were quantified in cod liver samples from Iceland and the Baltic Sea. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1519 / 1530
页数:12
相关论文
共 6 条
  • [1] A congener-specific method for the quantification of camphechlor (toxaphene) residues in fish and other foodstuffs
    Alder, L
    Vieth, B
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 354 (01): : 81 - 92
  • [2] Determination of Toxaphene Residues in Fish Foodstuff by GC–MS
    D. Attard Barbini
    P. Stefanelli
    S. Girolimetti
    A. Di Muccio
    R. Dommarco
    Bulletin of Environmental Contamination and Toxicology, 2007, 79 : 226 - 230
  • [3] Determination of toxaphene residues in fish foodstuff by GC-MS
    Barbini, D. Attard
    Stefanelli, P.
    Girolimetti, S.
    Di Muccio, A.
    Dommarco, R.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2007, 79 (02) : 226 - 230
  • [4] Congener specific determination of toxaphene residues in fish liver oil using gas chromatography coupled to ion trap MS/MS
    Bernardo, FJG
    Fernández, MA
    González, MJ
    CHEMOSPHERE, 2005, 61 (03) : 398 - 404
  • [5] COMPARISON OF GC-ECD AND GC-MS FOR THE DETERMINATION OF SPECIFIC POLYCHLORINATED BIPHENYL CONGENER RESIDUES IN HUMAN ADIPOSE-TISSUE
    WILLIAMS, DT
    LEBEL, GL
    CHEMOSPHERE, 1990, 21 (4-5) : 487 - 494
  • [6] Separation of toxic coplanar PCB congeners from other congeners in marine sediments and marine fish tissues using Florisil and GC-ECD
    Rieck, RH