ABO Blood Group Is Associated with Response to Inhaled Nitric Oxide in Neonates with Respiratory Failure

被引:7
|
作者
El-Ferzli, George T. [1 ,2 ]
Dreher, Mackenzie [1 ,2 ]
Patel, Rakesh P. [3 ,4 ]
Ambalavanan, Namasivayam [1 ,2 ]
机构
[1] Univ Alabama Birmingham, Dept Pediat, Ctr Free Radical Biol, Birmingham, AL USA
[2] Univ Alabama Birmingham, Dept Pediat, Pulm Injury Repair Ctr, Birmingham, AL USA
[3] Univ Alabama Birmingham, Dept Pathol, Ctr Free Radical Biol, Birmingham, AL 35294 USA
[4] Univ Alabama Birmingham, Dept Pathol, Pulm Injury Repair Ctr, Birmingham, AL 35294 USA
来源
PLOS ONE | 2012年 / 7卷 / 09期
基金
美国国家卫生研究院;
关键词
PERSISTENT PULMONARY-HYPERTENSION; CONTROLLED-TRIAL; VENTILATION; SELECTIN; NEWBORN; INFANTS; RISK;
D O I
10.1371/journal.pone.0045164
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Inhaled nitric oxide (iNO) reduces death or need for extracorporeal membrane oxygenation (ECMO) in infants with persistent pulmonary hypertension of the newborn (PPHN). However, the response to iNO is variable and only 50-60% of infants demonstrate a response to iNO. It is not known why only some infants respond to iNO. Adults and children with blood groups B or AB do not respond as well to iNO as those with blood groups O/A. Methods/Principal Findings: To determine if blood group was associated with iNO response in newborn infants, a retrospective medical record review was done of infants admitted to a regional NICU from 2002-9 with a diagnosis of PPHN. Data were collected during the first twelve hours post-initiation of treatment. Of 86 infants diagnosed with PPHN, 23 infants had blood group A [18 received iNO], 21 had group B [18 with iNO], 40 had group O [36 with iNO], and 2 had group AB [both received iNO]. Change in PaO2/FiO(2) was less in infants with blood group A, of whom less than half were responders (Delta PaO2/FiO(2)>20%) at 12 h versus 90% of infants with either O or B. Race, sex, birth weight, gestational age, Apgar scores at 1 and 5 minutes, and baseline PaO2/FiO(2) were similar among groups. Outcomes including need for ECMO, death, length of ventilatory support, length of iNO use, and hospital stay were statistically not different by blood groups. Conclusions/Significance: Our results indicate that blood group influences iNO response in neonates. We hypothesize that either there is genetic linkage of the ABO gene locus with vasoregulatory genes, or that blood group antigens directly affect vascular reactivity.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] ABO blood group and inhaled nitric oxide in acute respiratory distress syndrome
    Weimann, J
    Bauer, H
    Bigatello, L
    Bloch, KD
    Martin, E
    Zapol, WM
    LANCET, 1998, 351 (9118): : 1786 - 1787
  • [2] Treatment with Inhaled Nitric Oxide (iNO) In Neonates with Respiratory Failure Associated with Pulmonary Hypertension (PH)
    M T Mazzucchelli
    E Domínguez
    C Cannizzaro
    P Bellani
    C Couceiro
    Pediatric Research, 1998, 44 (5) : 814 - 814
  • [3] Response of premature infants with severe respiratory failure to inhaled nitric oxide
    VanMeurs, KP
    Rhine, WD
    Asselin, JM
    Durand, DJ
    Peverini, R
    Dudell, G
    Butler, S
    Durand, D
    Asselin, J
    VanMeurs, K
    Rhine, W
    PEDIATRIC PULMONOLOGY, 1997, 24 (05) : 319 - 323
  • [4] Inhaled nitric oxide in acute respiratory failure
    Rouby, JJ
    VASCULAR ENDOTHELIUM: RESPONSES TO INJURY, 1996, 281 : 181 - 203
  • [5] Inhaled nitric oxide in acute respiratory failure
    Young, JD
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (06) : 695 - 696
  • [6] Response to Inhaled Nitric Oxide in Premature and Term Neonates
    Thomas Hoehn
    Martin F. Krause
    Drugs, 2001, 61 : 27 - 39
  • [7] Response to inhaled nitric oxide in premature and term neonates
    Hoehn, T
    Krause, MF
    DRUGS, 2001, 61 (01) : 27 - 39
  • [8] Inhaled nitric oxide in premature neonates with severe hypoxaemic respiratory failure: a randomised controlled trial
    Kinsella, JP
    Walsh, WF
    Bose, CL
    Gerstmann, DR
    Labella, JJ
    Sardesai, S
    Walsh-Sukys, MC
    McCaffrey, MJ
    Cornfield, DN
    Bhutani, VK
    Cutter, GR
    Baier, M
    Abman, SH
    LANCET, 1999, 354 (9184): : 1061 - 1065
  • [9] Inhaled nitric oxide in preterm and term neonates with hypoxemic respiratory failure and persistent pulmonary hypertension
    Du, LZ
    Shi, LP
    Sun, MY
    Zhou, BH
    Chen, C
    Shao, XM
    Zhang, XD
    Lü, Y
    Sun, B
    ACTA PHARMACOLOGICA SINICA, 2002, 23 : 69 - 73
  • [10] Efficacy of inhaled nitric oxide in neonates with hypoxic respiratory failure and pulmonary hypertension: the Japanese experience
    Suzuki, Satoshi
    Togari, Hajime
    Potenziano, Jim L.
    Schreiber, Michael D.
    JOURNAL OF PERINATAL MEDICINE, 2018, 46 (06) : 657 - 663