INFLUENCE OF DIFFERENT SYSTEMS OF MINIMUM VENTILATION ON AIR QUALITY IN BROILER HOUSES

被引:9
|
作者
Menegali, Irene [1 ]
Tinoco, Ilda F. F. [2 ]
Zolnier, Sergio [2 ]
Carvalho, Cinara da C. S. [3 ]
Guimaraes, Maria C. de C. [4 ]
机构
[1] UFMG, ICA, Montes Claros, MG, Brazil
[2] Univ Fed Vicosa, DEA, Vicosa, MG, Brazil
[3] Univ Estadual Montes Claros, Dept Ciencias Agr, Janauba, MG, Brazil
[4] Univ Fed Vales Jequitinhonha & Mucuri, Depto Agron, Fac Ciencias Agr, Diamantina, MG, Brazil
来源
ENGENHARIA AGRICOLA | 2012年 / 32卷 / 06期
关键词
aviculture; broiler chicks; gas concentration; air renovation; POULTRY HOUSES;
D O I
10.1590/S0100-69162012000600003
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
To maintain a competitive development of the Brazilian aviculture, some measures must be taken to enable the identification and reduction of risks to the health of birds, as well as for the physical environment. Therefore, the aim of this study was to evaluate the effectiveness of three different systems of minimum ventilation (positive pressure - SVMP, negative pressure - SVMN and natural ventilation - SVMNat) in the air quality during the first 21 days of life of broiler chicks, during winter. Three points were selected along the length to verify ammonia, carbon monoxide and oxygen concentrations at 3a.m., 9a.m., 3p.m. and 9p.m., by the respiration level of birds and workers. The averages of pollutant gases did not exceed the tolerance levels for the three minimum ventilation systems evaluated, which is 20 and 10ppm for the birds level and 20 and 39ppm for the workers level, for ammonia and carbon monoxide, respectively. It was evident that the minimum ventilation systems were appropriately sized for the required minimum ambient air renovation, in respect to ventilation rates applied for the SVMN and SVMP systems, and with air velocity at levels that do not stress the chicks, including for the SVMNat. The three studied systems of minimum ventilation allowed the birds to externalize their productive performance, with values close to the ones considered satisfactory for all evaluated parameters, in accordance with the Brazilian aviculture standards.
引用
收藏
页码:1024 / 1033
页数:10
相关论文
共 50 条
  • [1] GEOSTATISTIC TO EVALUATE THE ENVIRONMENTAL CONTROL IN DIFFERENT VENTILATION SYSTEMS IN BROILER HOUSES
    Curi, Thayla M. R. De C.
    Vercellino, Rimena Do A.
    Massari, Juliana M.
    Souza, Zigomar M.
    De Moura, Daniella J.
    [J]. ENGENHARIA AGRICOLA, 2014, 34 (06): : 1062 - 1074
  • [2] Air quality in relation with type of bedding in broiler houses
    Popescu, S.
    Borda, C.
    Spinu, M.
    Niculae, M.
    Pall, E.
    Cernea, M.
    Petrean, A. Blaga
    [J]. JOURNAL OF BIOTECHNOLOGY, 2019, 305 : S76 - S76
  • [3] Influence of litter ventilation on mite populations and mould in broiler houses in comparison with conventional litter systems
    Ehrnsberger, R
    Dabert, J
    Krawczynski, R
    [J]. ARCHIV FUR GEFLUGELKUNDE, 2000, 64 (03): : 99 - 108
  • [4] Minimum ventilation requirement and associated energy cost for aerial ammonia control in broiler houses
    Xin, H
    Berry, IL
    Tabler, GT
    [J]. TRANSACTIONS OF THE ASAE, 1996, 39 (02): : 645 - 648
  • [5] VENTILATION MONITORING OF BROILER HOUSES IN CALIFORNIA
    Lin, X. -J.
    Cortus, E. L.
    Zhang, R.
    Jiang, S.
    Heber, A. J.
    [J]. TRANSACTIONS OF THE ASABE, 2011, 54 (03) : 1059 - 1068
  • [6] Positioning of sensors for control of ventilation systems in broiler houses: a case study
    Ridolfi de Carvalho Curi, Thayla Morandi
    Conti, Dante
    Vercellino, Rimena do Amaral
    Massari, Juliana Maria
    de Moura, Daniella Jorge
    de Souza, Zigomar Menezes
    Montanari, Rafael
    [J]. SCIENTIA AGRICOLA, 2017, 74 (02): : 101 - 109
  • [7] Use of geostatistics on broiler production for evaluation of different minimum ventilation systems during brooding phase
    Ridolfi de Carvalho, Thayla Morandi
    de Moura, Daniella Jorge
    de Souza, Zigomar Menezes
    de Souza, Gustavo Soares
    de Freitas Bueno, Leda Gobbo
    Oliveira de Lima, Karla Andrea
    [J]. REVISTA BRASILEIRA DE ZOOTECNIA-BRAZILIAN JOURNAL OF ANIMAL SCIENCE, 2012, 41 (01): : 194 - 202
  • [8] Microbiological air quality in office buildings equipped with different ventilation systems
    Golofit-Szymczak, Malgorzata
    Gorny, Rafal L.
    [J]. INDOOR AIR, 2018, 28 (06) : 792 - 805
  • [9] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ENVIRONMENT INTERNATIONAL, 1983, 9 (02) : 153 - 156
  • [10] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1983, 177 (06): : 571 - 571