Successful Plate Fixation with Long Intramedullary Fibula Bone Graft for Periprosthetic Femur Fracture: A Case Report

被引:1
|
作者
Yeh, Kuei-Lin [1 ,2 ]
Liaw, Chen-Kun [3 ,4 ,5 ]
Fuh, Chiou-Shann [2 ]
Chen, Chu-Song [2 ]
Chiang, Chen-Hao [1 ]
Shih, Kao-Shang [6 ,7 ]
机构
[1] Ditmanson Med Fdn, Chia Yi Christian Hosp, Dept Orthopaed, 539 Zhongxiao Rd, Chiayi 600566, Taiwan
[2] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, 1,Sec 4,Roosevelt Rd, Taipei 106216, Taiwan
[3] Taipei Med Univ, Coll Med, Sch Med, Dept Orthopaed, 250 Wuxing St, Taipei 11031, Taiwan
[4] Taipei Med Univ, Shuang Ho Hosp, Dept Orthopaed, 291 Zhongzheng Rd, New Taipei 23561, Taiwan
[5] Taipei Med Univ, Coll Biomed Engn, Res Ctr Biomed Device, Grad Inst Biomed Optomechatron, Taipei 11031, Taiwan
[6] Shin Kong Wu Ho Mem Hosp, Dept Orthopaed, 95 Wenchang Rd, Taipei 111045, Taiwan
[7] Fu Jen Catholic Univ, Sch Med, Dept Med, 510 Zhongzheng Rd, New Taipei 242062, Taiwan
来源
MEDICINA-LITHUANIA | 2022年 / 58卷 / 09期
关键词
periprosthetic fracture; osteoporosis; allogenous fibula bone graft; distal femur fracture; TOTAL KNEE ARTHROPLASTY; DISTAL FEMORAL REPLACEMENT; STABILIZATION; ALLOGRAFT; HIP;
D O I
10.3390/medicina58091148
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Treatment of a displaced or comminuted periprosthetic distal femur fracture is challenging, especially in patients with osteoporosis. In this case report, we shared our successful surgical experience of using a long intramedullary fibula bone graft in a plate fixation surgery for a periprosthetic distal femur fracture in an extremely elderly patient with osteoporosis. Case report: A 95-year-old woman with severe osteoporosis (bone mineral density level: -3.0) presented with right knee pain and deformity after a fall, and a right periprosthetic distal femur fracture was identified. The patient underwent an open reduction and an internal plate fixation surgery with the application of a long intramedullary fibular bone graft. Due to a solid fixation, immediate weight-bearing was allowed after the surgery. She could walk independently without any valgus or varus malalignment or shortening 3 months after the surgery. A solid union was achieved 4 months postoperatively. Conclusions: We present a case wherein a long intramedullary allogenous fibula strut bone graft was used successfully to treat a right periprosthetic femur fracture in an extremely elderly patient. A long allogenous fibula bone graft can act not only as a firm structure for bridging the bone defect but also as a guide for precise component alignment. We believe this treatment option for periprosthetic fractures is beneficial for achieving biological and mechanical stability and facilitates early mobilization and weight-bearing for the patient.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The fibula as a bone graft for ununited fracture of the neck of the femur
    Dolbey, RV
    BRITISH MEDICAL JOURNAL, 1923, 1923 : 1151 - 1151
  • [2] Intramedullary plate fixation of a distal humerus fracture: A case report
    Russell, GV
    Pearsall, AW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) : 353 - 356
  • [3] Periprosthetic distal femur fracture: Plate versus nail fixation
    Haidukewych, George J.
    Gliatis, John
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 219 - 221
  • [4] Prehabilitation in a Periprosthetic Fracture of the Femur: A Case Report
    Bhoge, Shruti S.
    Phansopkar, Pratik
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [5] Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation
    Ehlinger, M.
    Brinkert, D.
    Besse, J.
    Adam, P.
    Arlettaz, Y.
    Bonnomet, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (05) : 560 - 564
  • [7] Treatment of supracondylar nonunions of the femur with plate fixation and bone graft
    Chapman, MW
    Finkemeier, CG
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09): : 1217 - 1228
  • [8] Fixation of the comminuted distal-femur fracture with intramedullary and extramedullary plates: A rare case report
    Zhang, Jian
    Liang, Jiahui
    Wang, Jingshu
    Tang, Xin
    ASIAN JOURNAL OF SURGERY, 2023, 46 (06) : 2479 - 2480
  • [9] Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation
    Waehnert, Dirk
    Schroeder, Richard
    Schulze, Martin
    Westerhoff, Peter
    Raschke, Michael
    Stange, Richard
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 47 - 53
  • [10] Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation
    Dirk Wähnert
    Richard Schröder
    Martin Schulze
    Peter Westerhoff
    Michael Raschke
    Richard Stange
    International Orthopaedics, 2014, 38 : 47 - 53