No-Load Voltage Waveform Optimization and Damper Bars Heat Reduction of Tubular Hydrogenerator by Different Degree of Adjusting Damper Bar Pitch and Skewing Stator Slot

被引:21
|
作者
Fan, Zhen-nan [1 ]
Liao, Yong [1 ]
Han, Li [1 ]
Xie, Li-dan [2 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400030, Peoples R China
[2] Guodian Nanjing Automat Co Ltd, Nanjing 210003, Peoples R China
关键词
Damper bar heat; electromagnetic and temperature field; finite element analysis; hydrogenerator; voltage harmonic analysis;
D O I
10.1109/TEC.2013.2259628
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To analyze the influence of no-load voltage waveforms and damper bar losses and heat by the damper bar pitch and stator slot skew, finite-element model (FEM) computations are conducted. The calculation models are multislice moving electromagnetic field-circuit coupling model for the hydrogenerator and three-dimensional temperature field FEM for the rotor. This analysis considers the factors such as the rotor motion and the nonlinearity of time-varying electromagnetic field, the anisotropic heat conduction of the rotor core lamination, and the different heat dissipation conditions on the windward and the leeward sides of the poles. Then, the no-load voltage waveforms of a 36 MW tubular hydrogenerator are optimized and the damper bar heat at the rated load is reduced with the design scheme by adjusting the damper bar pitch and the stator slot skew. The results show that the waveforms of the no-load voltage are improved and the temperature of damper bars are reduced when reasonably increasing damper bar pitch and skewing stator slots. The calculated results are well coincident with the test data. The research is helpful for improving the design standard and enhancing the operation reliability of the large tubular hydrogenerator and electric network.
引用
收藏
页码:461 / 469
页数:9
相关论文
共 6 条
  • [1] Effect of Damper Winding and Stator Slot Skewing Structure on No-Load Voltage Waveform Distortion and Damper Bar Heat in Large Tubular Hydro Generator
    Fan, Zhen-Nan
    Li-Han
    Liao, Yong
    Xie, Li-Dan
    Wen, Kun
    Wang, Jun
    Dong, Xiu-Cheng
    Yao, Bing
    IEEE ACCESS, 2018, 6 : 22281 - 22291
  • [3] Failure Analysis and No-load Voltage Waveform Optimization and damper bar Heat Reduction of a large Tubular Hydro-Generator
    Gao Jian
    Fan Zhen-nan
    MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 834 - 838
  • [4] The No-load Voltage Waveform and Damper Bar Temperature Computation of Integral Number Slots Large Hydro-Generator which the Number of Damper Bars per Pole Increased
    Yang Ru
    Li Hong-jun
    Fan Zhen-nan
    MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 843 - +
  • [5] Effect of Shifting the Pole-shoe and Damper-bar Centerlines on the No-load Voltage Waveform of a Tubular Hydro-generator
    Fan, Zhen-nan
    Han, Li
    Liao, Yong
    Xie, Li-dan
    Wen, Kun
    Wang, Jun
    Dong, Xiu-cheng
    Yao, Bing
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (03) : 1294 - 1303
  • [6] Optimization of No-Load Voltage Waveform in a large Hydro-Generator by the Schemes which Shift the Damper Winding and Skew Stator Slots
    Luo, Yong-gang
    Fan, Zhen-nan
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 397 - +