Radiation dose in dental radiology

被引:129
|
作者
Cohnen, M
Kemper, J
Möbes, O
Pawelzik, J
Mödder, U
机构
[1] Univ Dusseldorf, Inst Diagnost Radiol, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Dept Oral Surg, Westdeutsch Kieferklin, D-4000 Dusseldorf, Germany
关键词
dental radiology; radiation exposure; dose reduction; image noise;
D O I
10.1007/s003300100928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT standard parameters were used while variables in CT included mA. pitch. and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT these maximum doses were 0.65, 4.2. and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology.
引用
收藏
页码:634 / 637
页数:4
相关论文
共 50 条
  • [1] Radiation Dose in Dental Radiology
    Kara, U.
    Yildirim, D.
    Akkurt, I.
    [J]. ACTA PHYSICA POLONICA A, 2016, 130 (01) : 407 - 408
  • [2] Radiation dose in dental radiology
    M. Cohnen
    J. Kemper
    O. Möbes
    J. Pawelzik
    U. Mödder
    [J]. European Radiology, 2002, 12 : 634 - 637
  • [3] Measurement of radiation dose in dental radiology
    Helmrot, E
    Carlsson, GA
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 168 - 171
  • [4] Radiation exposure and dose evaluation in intraoral dental radiology
    Poppe, B.
    Looe, H. K.
    Pfaffenberger, A.
    Eenboom, F.
    Chofor, N.
    Sering, M.
    Ruehmann, A.
    Poplawski, A.
    Willborn, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 123 (02) : 262 - 267
  • [5] GENETIC DOSE FROM DENTAL RADIOLOGY
    SMITH, NJD
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (538): : 733 - &
  • [6] Measurement of dose in panoramic dental radiology
    Williams, JR
    Montgomery, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873): : 1002 - 1006
  • [7] THE LEADED APRON REVISITED - DOES IT REDUCE GONADAL RADIATION-DOSE IN DENTAL RADIOLOGY
    WOOD, RE
    HARRIS, AMP
    VANDERMERWE, EJ
    NORTJE, CJ
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1991, 71 (05): : 642 - 646
  • [8] Methods of determining the effective dose in dental radiology
    Thilander-Klang, Anne
    Helmrot, Ebba
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 306 - 309
  • [9] Dose evaluation and quality criteria in dental radiology
    Gori, C
    Rossi, F
    Stecco, A
    Villari, N
    Zatelli, G
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 225 - 227
  • [10] Methods for monitoring patient dose in dental radiology
    Helmrot, Ebba
    Thilander-Klang, Anne