Start-up, heat transfer and flow characteristics of silicon-based micro pulsating heat pipes

被引:134
|
作者
Qu, Jian [1 ,2 ]
Wu, Huiying [1 ]
Cheng, Ping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
[2] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro pulsating heat pipe; Silicon chip; Start-up; Thermal performance; Flow pattern; FABRICATION; CONDENSATION; ARRAYS;
D O I
10.1016/j.ijheatmasstransfer.2012.06.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
A simultaneous visualization and measurement study has been carried out to investigate the start-up, heat transfer and flow characteristics of three silicon-based micro pulsating heat pipes (MPHPs) with the trapezoidal cross-section having hydraulic diameters of 251 mu m (#1), 352 mu m (#2) and 394 mu m (#3), respectively. Experiments were performed under different working fluids, filling ratios, inclination angles (bottom heating mode) and heating power inputs. It is found that (1) the silicon-based MPHPs could start up within 200 s when charged with R113 or FC-72, but they failed to start up at all inclination angle when charged with water or ethanol having lower (dP/dT)(sat), higher viscosity, higher latent heat and higher surface tension at the same temperature. During the start-up period, no obvious nucleation was observed. After the start-up period, MPHPs entered the operation period. The silicon-based MPHP could operate normally even at a Bond number of 0.26 and a hydraulic diameter of 251 mu m, both smaller than the corresponding values in literatures; (2) the thermal performance of MPHPs depends greatly on the type of working fluid, filling ratio and inclination angle. At the lower power input. MPHPs charged with R113 showed better thermal performance than that charged with FC-72, however, the latter exceeded the former at the higher power input. For the same working fluid, there existed an optimal filling ratio corresponding to the best thermal performance of MPHPs, which was about 52%, 55% and 47% for MPHPs #1, #2 and #3 at the vertical orientation (90 degrees), respectively. When the MPHPs turned from the vertical to the horizontal orientation, the thermal performance tended to be decreased, indicating that the gravity effect cannot be ignored in these silicon-based MPHPs. In MPHP #3 at the inclination angle from 70 degrees to 90 degrees, there appeared a special thermal resistance curve with two local maximum points, which is absent in the traditional PHPs; (3) in the operation period of larger MPHP #3, nucleation boiling, bulk circulation and injection flow were all observed, while these flow patterns were absent in the smaller MPHPs #1 and #2. Intense liquid film evaporation, instead of bubbles' generation and expansion which usually activated the oscillation flow in macro-PHPs, drove the two-phase flow in the smaller MPHPs #1 and #2. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6109 / 6120
页数:12
相关论文
共 50 条
  • [1] Flow visualization of silicon-based micro pulsating heat pipes
    QU Jian WU HuiYing Key Laboratory for Power Machinery and Engineering of Ministry of EducationSchool of Mechanical EngineeringShanghai Jiaotong UniversityShanghai China
    [J]. Science China(Technological Sciences)., 2010, 53 (04) - 990
  • [2] Flow visualization of silicon-based micro pulsating heat pipes
    Jian Qu
    HuiYing Wu
    [J]. Science China Technological Sciences, 2010, 53 : 984 - 990
  • [3] Flow visualization of silicon-based micro pulsating heat pipes
    QU Jian & WU HuiYing Key Laboratory for Power Machinery and Engineering of Ministry of Education
    [J]. Science China Technological Sciences, 2010, (04) : 984 - 990
  • [4] Flow visualization of silicon-based micro pulsating heat pipes
    Qu Jian
    Wu HuiYing
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (04) : 984 - 990
  • [5] Experimental research on the start-up characteristics and heat transfer performance of pulsating heat pipes with rectangular channels
    Hua, Chao
    Wang, Xuehui
    Gao, Xu
    Zheng, Haoce
    Han, Xiaohong
    Chen, Guangming
    [J]. APPLIED THERMAL ENGINEERING, 2017, 126 : 1058 - 1062
  • [6] Start-up and heat transfer characteristics of a pulsating heat pipe with graphene oxide nanofluids
    Zhang, Miao
    Yang, Honghai
    Yin, Yong
    Xu, Yue
    Shen, Junjie
    Lu, Xincheng
    Shi, Weigang
    Wang, Jun
    [J]. Huagong Xuebao/CIESC Journal, 2022, 73 (03): : 1136 - 1146
  • [7] Numerical investigation on the start-up and heat transfer performance of dual-diameter pulsating heat pipes
    Liu, Yuewen
    Dan, Dan
    Wei, Mingshan
    Zheng, Siyu
    Sun, Jixian
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236
  • [8] A review on start-up characteristics of the pulsating heat pipe
    Zhang, Dongwei
    He, Zhuantao
    Jiang, Erhui
    Shen, Chao
    Zhou, Junjie
    [J]. HEAT AND MASS TRANSFER, 2021, 57 (05) : 723 - 735
  • [9] A review on start-up characteristics of the pulsating heat pipe
    Dongwei Zhang
    Zhuantao He
    Erhui Jiang
    Chao Shen
    Junjie Zhou
    [J]. Heat and Mass Transfer, 2021, 57 : 723 - 735
  • [10] Testing and Modeling of the Dynamic Response Characteristics of Pulsating Heat Pipes during the Start-up Process
    Xu Rongji
    Chen Hao
    Wu Qingping
    Xu Shuhui
    Wang Ruixiang
    [J]. JOURNAL OF THERMAL SCIENCE, 2019, 28 (01) : 72 - 81