Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring

被引:34
|
作者
Rastogi, Anju
Khanam, Samreen
Goel, Yashpal
Kamlesh
Thacker, Prolima
Kumar, Prateek
机构
[1] Guru Nanak Eye Ctr, Dept Ophthalmol, New Delhi, India
[2] Maulana Azad Med Coll, New Delhi, India
关键词
Astigmatism; cataract; toric intraocular lens; CLINICAL-OUTCOMES; CORNEAL ASTIGMATISM; IMPLANTATION; EFFICACY;
D O I
10.4103/ijo.IJO_875_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the rotational stability of toric intraocular lens (IOL) when co-implanted with a capsular tension ring (CTR) as compared to that of a toric IOL without a CTR. Methods: This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism >= 1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count <2000/mm(2) were excluded from the study. The eyes in both the groups underwent standard phacoemulsification and were implanted with a toric IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally. Results: Mean rotation of toric IOL at 3 months postoperatively was 1.85 +/- 1.72 degrees in Group A and 4.02 +/- 2.04 degrees in Group B. The difference was statistically significant (P = 0.003). Conclusion: Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 50 条
  • [1] Rotational stability of toric intraocular lenses with a newly modified capsular tension ring
    Zdral, John
    Werner, Liliana
    Mamalis, Nick
    Bontu, Sneha
    Kennedy, Sean
    Henderson, Bonnie A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (04): : 516 - 521
  • [2] Effect of Capsular Tension Ring Implantation on Postoperative Rotational Stability of a Toric IntraocuLar Lens
    Vokrojova, Magdalena
    Havlickova, Lenka
    Brozkova, Marketa
    Hlinomazova, Zuzana
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (03) : 186 - 192
  • [3] Rotation stability of a toric intraocular lens with a second capsular tension ring
    Sagiv, Oded
    Sachs, Dan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05): : 1098 - 1099
  • [4] Enhancing rotational stability of toric intraocular lenses using a type 2L Cionni capsular tension ring in patients with high myopia
    Tataru, Calin Petru
    Dogaroiu, Anca Cristina
    Tataru, Catalina Ioana
    Dogaroiu, Catalin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09): : 1219 - 1221
  • [5] Comparison of the effect of capsular bend on the rotational stability between 2 toric intraocular lenses
    Wang, Yiyi
    Lou, Xicong
    Qian, Shuyi
    Li, Yuanyuan
    Wu, Xueer
    Li, Siyan
    Wang, Yalan
    Zhao, Yune
    Chang, Pingjun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (03): : 283 - 288
  • [6] Comparison of Capsular Tension Ring Implantation before vs. after Toric Intraocular Lens for Rotational Stability
    Cetinkaya, Servet
    Ucar, Fikret
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (02) : 186 - 191
  • [7] Evaluation of unfolding speed and rotational stability of toric intraocular lenses under compression
    Murase, Kyoko
    Nakahata, Yoshihiro
    Nagasaka, Shinji
    Soda, Yasushi
    Ota, Ichiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [8] Effect of capsular bend on the rotational stability of toric intraocular lens
    Chang, Pingjun
    Chen, Dongjie
    Hu, Bin
    Wang, Yalan
    Qian, Shuyi
    Ding, Xixia
    Zhao, Yune
    EYE, 2023, 37 (03) : 480 - 485
  • [9] Effect of capsular bend on the rotational stability of toric intraocular lens
    Pingjun Chang
    Dongjie Chen
    Bin Hu
    Yalan Wang
    Shuyi Qian
    Xixia Ding
    Yune Zhao
    Eye, 2023, 37 : 480 - 485
  • [10] Rotational Stability of Toric Capsular Bag-Fixated Intraocular Lenses in Duet Procedure for Reversible Trifocality
    Baur, Isabella D.
    Auffarth, Gerd U.
    Koeppe, Maximilian K.
    Iabuz, Grzegorz
    Khoramnia, Ramin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 256 : 156 - 163