Thermal behavior of aqueous iron oxide nano-fluid as a coolant on a flat disc heater under the pool boiling condition

被引:81
|
作者
Salari, E. [1 ]
Peyghambarzadeh, S. M. [1 ]
Sarafraz, M. M. [2 ]
Hormozi, F. [2 ]
Nikkhah, V. [2 ]
机构
[1] Islamic Azad Univ, Mahshahr Branch, Dept Chem Engn, Coll Chem Engn, Mahshahr, Iran
[2] Semnan Univ, Fac Chem Petr & Gas Engn, Semnan, Iran
关键词
WATER NANOFLUID; ENHANCEMENT; WETTABILITY; PERFORMANCE; TUBES; ZNO;
D O I
10.1007/s00231-016-1823-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper experimentally focuses on the pool boiling heat transfer characteristics of gamma Fe3O4 aqueous nano-fluids on a flat disc heater. The nano-fluid used in this research was prepared using two-step method and was stabilized using nonylphenol ethoxylate nonionic surfactant, pH setting, and sonication process as well. Influence of different operating parameters such as heat flux (0-1546 kW/m(2)), mass concentration of nano-fluids (weight concentration 0.1-0.3 %), bubble formation, critical heat flux (1170 kW/m(2) for water, 1230 kW/m(2) (wt% = 0.1), 1320 kW/m(2) (wt% = 0.2), 1450 kW/m(2) (wt% = 0.3) and fouling on pool boiling heat transfer coefficient of nano-fluid as a thermal performance index were experimentally investigated and briefly discussed. Results demonstrated that the pool boiling heat transfer coefficient increases with increasing the mass concentration and the applied heat flux. In addition, the rate of bubble formation is significantly intensified at higher heat fluxes and subsequently, larger bubbles detach the surface due to the intensification of bubble coalescence. In terms of fouling formation, it can be stated that fouling of nano-fluids is a strong function of time and rate of deposition is increased over the extended time while the pool boiling heat transfer coefficient was not decreased over the time, as porous deposited layer on the surface are detached from the surface by bubble interactions. In terms of critical heat flux, capillary action of the deposited layer was found to be the main reason responsible for increasing the critical heat flux as liquid is stored inside the porous deposited layer, which enhances the surface toleration against the critical heat flux crisis.
引用
收藏
页码:265 / 275
页数:11
相关论文
共 5 条
  • [1] Thermal behavior of aqueous iron oxide nano-fluid as a coolant on a flat disc heater under the pool boiling condition
    E. Salari
    S. M. Peyghambarzadeh
    M. M. Sarafraz
    F. Hormozi
    V. Nikkhah
    [J]. Heat and Mass Transfer, 2017, 53 : 265 - 275
  • [2] Application of Spherical Copper Oxide (II) Water Nano-fluid as a Potential Coolant in a Boiling Annular Heat Exchanger
    Nikkhah, V.
    Sarafraz, M. M.
    Hormozi, F.
    [J]. CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2015, 29 (03) : 405 - 415
  • [3] Pool boiling heat transfer characteristics of iron oxide nano-suspension under constant magnetic field
    Sarafraz, M. M.
    Pourmehran, O.
    Yang, B.
    Arjomandi, M.
    Ellahi, R.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 147
  • [4] Pool boiling under the magnetic environment: experimental study on the role of magnetism in particulate fouling and bubbling of iron oxide/ethylene glycol nano-suspension
    H. Arya
    M. M. Sarafraz
    M. Arjomandi
    [J]. Heat and Mass Transfer, 2019, 55 : 119 - 132
  • [5] Pool boiling under the magnetic environment: experimental study on the role of magnetism in particulate fouling and bubbling of iron oxide/ethylene glycol nano-suspension
    Arya, H.
    Sarafraz, M. M.
    Arjomandi, M.
    [J]. HEAT AND MASS TRANSFER, 2019, 55 (01) : 119 - 132