A New Stability Enhancement Method Using KF Estimation for the PWM-SMC-Based Grid-Tied Inverter Under Weak Grid Condition

被引:5
|
作者
Chen, Bolin [1 ]
Wu, Weimin [1 ]
Gao, Chunxiao [1 ]
Orabi, Mohamed [2 ]
Koutroulis, Eftichis [3 ]
Chung, Henry [4 ,5 ]
Blaabjerg, Frede [6 ]
机构
[1] Shanghai Maritime Univ, Elect Engn Dept, Shanghai 201306, Peoples R China
[2] Aswan Univ, Fac Engn, Aswan 81542, Egypt
[3] Tech Univ Crete, Sch Elect & Comp Engn, Khania 73100, Greece
[4] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Ctr Smart Energy Convers & Utilizat Res, Hong Kong, Peoples R China
[6] Aalborg Univ, Energy Engn Dept, DK-9100 Aalborg, Denmark
基金
中国国家自然科学基金;
关键词
Grid-tied inverter (GTI); Kalman filter (KF); inductor-capacitor-inductor (LCL) filter; point of common coupling (PCC) voltage feedforward; sliding-mode control (SMC); weak grid; VARIABLE-STRUCTURE CONTROL; SLIDING-MODE CONTROL; LCL-FILTER; CONNECTED INVERTER; FEEDFORWARD; VSI; CONTROLLER; CONVERTERS; IMPEDANCE; IMPROVE;
D O I
10.1109/JESTPE.2022.3178733
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A sliding-mode control (SMC) technology is widely used in inductor-capacitor-inductor (LCL)-filtered grid-tied inverters (GTIs) due to its strong robustness against parameter drift. However, under weak grid conditions, the steady performance of GTI using conventional pulsewidth-modulation-based SMC (PWM-SMC) degrades, resulting in increased harmonics in grid-injected currents. One reason is that the voltage feedforward term at the point of common coupling (PCC) in the SMC loop causes the phase margin of the inverter output impedance to decrease. Another reason is that the gain of conventional PWM-SMC-based systems is not high enough, especially under weak grid conditions. This article proposes a PCC feedforward voltage reconstruction method (named KF-PWM-SMC) for a PWM-SMC-based controller using Kalman filter (KF) estimation. As a result, the phase and magnitude of the inverter output impedance at the desired frequency can be significantly improved. Moreover, the proposed PCC feedforward voltage extraction method can save the PCC voltage control sensor, thereby improving the reliability of the whole system. A 3-kW experimental GTI based on the dSPACE DS1202 platform has been developed to verify the feasibility of the proposed control strategy.
引用
下载
收藏
页码:6950 / 6959
页数:10
相关论文
共 50 条
  • [1] Stability Boundary Acquisition of Weak Grid-Tied Single-Stage Inverter
    Tu, Yiming
    Liu, Jinjun
    Liu, Zeng
    Xue, Danhong
    Cheng, Xiangpeng
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 448 - 454
  • [2] Impedance Scanning Method of Grid-tied Converters under Nonzero Grid Impedance Condition
    Zhang, Yuxin
    Du, Xiong
    Shi, Ying
    Zeng, Cheng
    Liu, Junliang
    Tai, Heng-Ming
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 728 - 733
  • [3] Stability Analysis of Grid-tied VSC Systems Under Weak Connection Conditions
    Wang X.
    Du W.
    Wang H.
    Du, Wenjuan (ddwenjuan@qq.com), 2018, Chinese Society for Electrical Engineering (38): : 1593 - 1604
  • [4] A Simple Impedance Reshaping Method for Stability Enhancement of Grid-Following Inverter Under Weak Grid
    Huang, Liang
    Wu, Chao
    Zhou, Dao
    Blaabjerg, Frede
    2021 IEEE 12TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2021,
  • [5] A Simple Impedance Reshaping Method for Stability Enhancement of Grid-Following Inverter Under Weak Grid
    Huang, Liang
    Wu, Chao
    Zhou, Dao
    Blaabjerg, Frede
    2021 IEEE 12TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2021,
  • [6] A Semidiscontinuous PWM Method for Suppression of the Resonant Current in a 48 Kw Grid-Tied PV Inverter
    Yang, Zhaoxia
    Wu, Liangcai
    Zeng, Jianwu
    Ren, Qixing
    Ge, Lei
    Liao, Zhengjun
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (05) : 6408 - 6417
  • [7] A novel PWM scheme for grid-tied inverter in micro-grid with enhanced power quality using silicon cells
    Yuvaraja, S.
    Salam, M. Syed Abdul
    Vijayaraja, L.
    Kesavan, Rupa
    Dhanasekar, R.
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 4298 - 4304
  • [8] Static Synchronous Generator Model: A New Perspective to Investigate Dynamic Characteristics and Stability Issues of Grid-Tied PWM Inverter
    Xiong, Liansong
    Zhuo, Fang
    Wang, Feng
    Liu, Xiaokang
    Chen, Ying
    Zhu, Minghua
    Yi, Hao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (09) : 6264 - 6280
  • [9] Line Impedance Cooperative Stability Region Identification Method for Grid-Tied Inverters Under Weak Grids
    Wang, Rui
    Sun, Qiuye
    Ma, Dazhong
    Hu, Xuguang
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (04) : 2856 - 2866
  • [10] Stability Assessment of a Three-Phase Grid-Tied PV Inverter with Eigenvalue-Based Method
    Yang, Zhiqing
    Wang, Qilei
    Warmuz, Julia
    De Doncker, Rik W.
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 722 - 727