Atrial Fibrillation Identification With PPG Signals Using a Combination of Time-Frequency Analysis and Deep Learning

被引:19
|
作者
Cheng, Peng [1 ]
Chen, Zhencheng [1 ,2 ,4 ]
Li, Quanzhong [3 ]
Gong, Qiong [1 ]
Zhu, Jianming [2 ]
Liang, Yongbo [1 ,2 ,4 ]
机构
[1] Guilin Univ Elect Technol, Sch Elect Engn & Automat, Guilin 541004, Peoples R China
[2] Guilin Univ Elect Technol, Sch Life & Environm Sci, Guilin 541004, Peoples R China
[3] Guilin Med Univ, Affiliated Hosp, Guilin 541001, Peoples R China
[4] Guangxi Key Lab Automat Detecting Technol & Instr, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrocardiography; Data models; Time-frequency analysis; Monitoring; Databases; Training; Machine learning; Atrial fibrillation; photoplethysmography (PPG); time-frequency analysis; convolutional neural networks (CNN); long short-term memory (LSTM); RESPIRATORY RATE; MANAGEMENT;
D O I
10.1109/ACCESS.2020.3025374
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Atrial fibrillation (AF) is the most common persistent arrhythmia and is likely to cause strokes and damage to heart function in patients. Electrocardiogram (ECG) is the gold standard for detecting AF. However, ECGs have short boards with short monitoring cycles and problems with gathering. It is also difficult to detect a burst AF through ECG. In contrast, photoplethysmography (PPG) is easy to perform and suitable for long-term monitoring. In this study, we propose a method that combines time-frequency analysis with deep learning and identifies AF based on PPG. The advantage of the method is that there is no need for the noise filtering and feature extraction of PPG, and it has a high generalization capability. The data for the experiment came from three publicly accessible databases. The first part of the experimental method uses data augmentation to convert the 10 s PPG segment into a time-frequency chromatograph by means of time-frequency analysis. The second part inputs the chromatograph into a hybrid framework that combines a convolutional neural network (CNN) and long short-term memory (LSTM) for AF/nonAF classification. The experimental results show that the method has a high classification accuracy, sensitivity, specificity, and F1 score, which are equal to 98.21%, 98.00%, 98.07% and 98.13%, respectively. The area under the receiver operating characteristic curve (AUC) is 0.9959. The model we propose not only aids doctors in diagnosing AF but also provides a method for identifying AF through portable wearable devices.
引用
收藏
页码:172692 / 172706
页数:15
相关论文
共 50 条
  • [1] Improved Time-Frequency Analysis of Atrial Fibrillation Signals Using Spectral Modeling
    Corino, Valentina D. A.
    Mainardi, Luca T.
    Stridh, Martin
    Sornmo, Leif
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (12) : 2723 - 2730
  • [2] Signal Quality Assessment of PPG Signals using STFT Time-Frequency Spectra and Deep Learning Approaches
    Chen, Jianzhong
    Sun, Ke
    Sun, Yi
    Li, Xinxin
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1153 - 1156
  • [3] Shape characterization of atrial fibrillation using time-frequency analysis
    Stridh, M
    Sörnmo, L
    COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 : 17 - 20
  • [4] Monitoring Atrial Fibrillation Using PPG Signals and a Smartphone
    Estrella-Gallego, A.
    Vazquez-Briseno, M.
    Nieto-Hipolito, J., I
    Gutierrez-Lopez, E.
    Sanchez-Lopez, J. D.
    Garcia-Berumen, A.
    Rivera-Rodriguez, R.
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2020, 16 (03) : 60 - 74
  • [5] Time-Frequency Analysis of the Endocavitarian Signal in Paroxysmal Atrial Fibrillation
    Pagana, Guido
    Galleani, Lorenzo
    Gross, Stefano
    Roch, Massimo Ruo
    Pastore, Erica
    Poggio, Mauro
    Quaranta, Greta
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (10) : 2838 - 2844
  • [6] Biomedical signals analysis using time-frequency
    Elouaham, Samir
    Latif, Rachid
    Dliou, Azzedine
    Maoulainine, Fadl
    Laaboubi, Mostafa
    PROCEEDINGS OF 2012 INTERNATIONAL CONFERENCE ON COMPLEX SYSTEMS (ICCS12), 2012, : 278 - 283
  • [7] Bridge Damage Identification Using Deep Neural Networks on Time-Frequency Signals Representation
    Santaniello, Pasquale
    Russo, Paolo
    SENSORS, 2023, 23 (13)
  • [8] Using PPG Signals and Wearable Devices for Atrial Fibrillation Screening
    Yang, Chengming
    Veiga, Cesar
    Rodriguez-Andina, Juan J.
    Farina, Jose
    Iniguez, Andres
    Yin, Shen
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (11) : 8832 - 8842
  • [9] Segmentation and identification of some pathological phonocardiogram signals using time-frequency analysis
    Boutana, D.
    Benidir, M.
    Barkat, B.
    IET SIGNAL PROCESSING, 2011, 5 (06) : 527 - 537
  • [10] Rapid identification of time-frequency domain gravitational wave signals from binary black holes using deep learning
    王钰鑫
    金上捷
    孙天阳
    张敬飞
    张鑫
    Chinese Physics C, 2024, 48 (12) : 236 - 248