Computer evaluation of left ventricular wall motion by means of shape-based tracking and symbolic description

被引:4
|
作者
Baroni, M [1 ]
机构
[1] Univ Florence, Dept Elect Engn, I-50139 Florence, Italy
关键词
cardiac left ventricular motion; contrast ventriculography; nonrigid shape tracking; symbolic motion description;
D O I
10.1016/S1350-4533(99)00033-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Relevant cardiac pathologies manifest themselves as abnormal movements of left ventricular (LV) myocardial wall. An objective quantification is usually accomplished by computer analysis of temporal sequences of LV contours, as obtained by angiography or echography. However the choice of the reference system for measuring motion is still open to discussion. Simple geometric models cannot deal with the non-uniform myocardial fibre structure, which gives rise to non-rigid movements, asynchronous even in normal subjects. Therefore, a new method, Curvature-Motion (CM), was developed for improving motion assessment. Since LV contour shape and position change smoothly throughout the cardiac cycle, the points of curvature extremes are tracked frame-to-frame and selected by exploiting physiologically-based assumptions; then, the points lying among these landmarks are mapped onto sequential contours, according to local displacements and curvature changes. In this way point-trajectories are allowed to be curvilinear and different in systole and diastole. CM gave no significant differences in estimating the known motion of computer-generated contours (R=0.88), unlike other methods commonly adopted (R<0.80). Moreover, for the evaluation of regional wall motion of a pre-classified set of angiographic contours, CM showed a greater specificity (88%) and accuracy (90%) with respect to the centre-line method (respectively 83% and 87%). Finally, a fuzzy logic inference system is proposed for translating significant motion patterns from the quantitative form, as provided by the analysis method, into the linguistic terms used by cardiologists in their clinical examinations. This makes the interpretation of quantitative analysis easier and allows medical users to interact with the system for searching particular properties in a single clinical report as well as in a large database. (C) 1999 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:73 / 85
页数:13
相关论文
共 50 条
  • [1] Shape-based tracking of left ventricular wall motion
    McEachen, JC
    Duncan, JS
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) : 270 - 283
  • [2] 3D SHAPE-BASED TRACKING OF LEFT-VENTRICULAR WALL-MOTION - EXPERIMENTAL VALIDATION
    DUNCAN, JS
    SINUSAS, AJ
    CONSTABLE, RT
    STAIB, LH
    DIONE, D
    SHI, QX
    SHI, PC
    AMINI, AA
    HELLER, E
    MCCAULEY, T
    SINGER, M
    CHAKRABORTY, A
    GORE, JC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A181 - A181
  • [3] Left ventricular wall motion tracking via deformable shape loci
    Clary, GJ
    Pizer, SM
    Fritsch, DS
    Perry, JR
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 271 - 276
  • [4] Left ventricular shape-based contractility index
    Zhong, Liang
    Ghista, Dhanjoo N.
    Ng, Eddie Y. K.
    Lim, Soo T.
    Chua, Terrance S. J.
    Lee, Chuen N.
    JOURNAL OF BIOMECHANICS, 2006, 39 (13) : 2397 - 2409
  • [5] Evaluation of left ventricular regional wall motion by means of myocardial tagging in apical hypertrophy
    Tsukamoto, M
    Hirasaki, S
    Matsuo, A
    Matsui, H
    Nakamura, T
    Azuma, A
    Sugihara, H
    Kuribayashi, T
    Maeda, T
    Nakagawa, M
    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE, 1999, 1192 : 317 - 320
  • [6] NONRIGID MOTION MODELS FOR TRACKING THE LEFT-VENTRICULAR WALL
    AMINI, AA
    OWEN, RL
    ANANDAN, P
    DUNCAN, JS
    LECTURE NOTES IN COMPUTER SCIENCE, 1991, 511 : 343 - 357
  • [7] Quantitative evaluation of left ventricular wall motion by MRI tagging
    Johnson, T
    Hahn, D
    Sandstede, J
    RADIOLOGE, 2004, 44 (02): : 158 - 163
  • [8] COMPUTER ASSESSMENT OF LEFT-VENTRICULAR WALL MOTION - THE ALVEN EXPERT SYSTEM
    TSOTSOS, JK
    COMPUTERS AND BIOMEDICAL RESEARCH, 1985, 18 (03): : 254 - 277
  • [9] REGIONAL EVALUATION OF THE LEFT-VENTRICULAR WALL MOTION BY RADIONUCLIDE VENTRICULOGRAPHY
    TARKOWSKA, A
    ADAM, WE
    BITTER, F
    GEFFERS, H
    GARVIE, NW
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (650): : 120 - 124
  • [10] LEFT-VENTRICULAR WALL MOTION - A COMPARISON OF 6 EVALUATION METHODS
    HUHMANN, W
    DUANGPHUNG, K
    ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (12): : 818 - 826