Liquid heparin anticoagulant produces more negative bias in the determination of ionized magnesium than ionized calcium

被引:8
|
作者
Shin, Cheung Soo
Chang, Chul Ho
Kim, Jeong-Ho [1 ]
机构
[1] Yonsei Univ, Coll Med, Yongdong Severance Hosp, Dept Lab Med, Seoul 135720, South Korea
[2] Yonsei Univ, Coll Med, Yongdong Severance Hosp, Dept Anesthesiol & Pain Med, Seoul 135720, South Korea
关键词
calcium; heparin; ion; magnesium;
D O I
10.3349/ymj.2006.47.2.191
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ionized calcium level in blood is known to be falsely decreased when self-prepared liquid heparin anticoagulant is used, due to dilution and binding effects. The effect of liquid heparin on the determination of ionized magnesium is not as well understood. We compared the effect of liquid sodium heparin on the determination of ionized calcium and magnesium in 44 clinical samples using two types of user-prepared heparin syringes which differed in the amount of residual heparin from the BD Preset (TM) reference syringe. With the type 1 syringe, the liquid heparin was expelled once or twice such that some heparin could be left in the dead space at the syringe hub, while the liquid sodium heparin was thoroughly expelled from the type 2 syringe. The ionized magnesium levels obtained with the type 1 syringe were significantly lower than the reference value (by 0.068 mmol/L) (p < 0.0001), while the value obtained with the type 2 syringe differed less from the reference, by only 0.014 mmol/L (p < 0.0001). The heparin binding effect resulted in more negative bias in ionized magnesium (- 0.026 +/- 0.032 mmol/L) than in ionized calcium (- 0.009 +/- 0.042 mmol/L, p < 0.0001). In conclusion, we recommend using lyophilized, calcium-balanced, heparinized syringes for the determination of ionized magnesium and ionized calcium due to the increased negative bias in ionized magnesium determinations. When user-prepared syringes are used, the thorough evacuation of heparin solution should be strictly prescribed.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 12 条
  • [1] Negative bias in ionized magnesium results on smokers
    Al-Ghoul, M.
    Hiemer, M. F.
    Miller, J. J.
    Elin, R. J.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A226 - A226
  • [2] SPECIFIC HEPARIN PREPARATIONS INTERFERE WITH THE SIMULTANEOUS MEASUREMENT OF IONIZED MAGNESIUM AND IONIZED CALCIUM
    LYON, ME
    BREMNER, D
    LAHA, T
    MALIK, S
    HENDERSON, PJ
    KENNY, MA
    CLINICAL BIOCHEMISTRY, 1995, 28 (01) : 79 - 84
  • [3] DETERMINATION OF IONIZED CALCIUM AND MAGNESIUM IN MILK
    CHRISTIANSON, G
    JENNESS, R
    COULTER, ST
    ANALYTICAL CHEMISTRY, 1954, 26 (12) : 1923 - 1927
  • [4] LIMITS FOR USE OF HEPARIN IN IONIZED CALCIUM DETERMINATION
    VEZZOLI, G
    ELLI, A
    PALAZZI, P
    ORAZI, E
    PERTICUCCI, E
    DIPALO, FQ
    BIANCHI, G
    RICERCA IN CLINICA E IN LABORATORIO, 1984, 14 (03): : 535 - 538
  • [5] ANTICOAGULANT-INDUCED PREANALYTICAL ERRORS IN IONIZED CALCIUM DETERMINATION ON BLOOD
    SACHS, C
    RABOUINE, P
    CHANEAC, M
    KINDERMANS, C
    DECHAUX, M
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (07): : 647 - 651
  • [6] PREANALYTICAL ERRORS IN IONIZED CALCIUM MEASUREMENTS INDUCED BY THE USE OF LIQUID HEPARIN
    SACHS, C
    RABOUINE, P
    CHANEAC, M
    KINDERMANS, C
    DECHAUX, M
    FALCHCHRISTIANSEN, T
    ANNALS OF CLINICAL BIOCHEMISTRY, 1991, 28 : 167 - 173
  • [8] The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements
    Toffaletti, JG
    Wildermann, RF
    CLINICA CHIMICA ACTA, 2001, 304 (1-2) : 147 - 151
  • [9] Sample stability and heparin interference in ionized calcium and ionized magnesium measurements in horses using the Stat Profile Prime Plus co-oximetry electrolyte analyzer
    Sanmarti, Julia
    Robles-Guirado, Jose Angel
    Jose-Cunilleras, Eduard
    Bassols, Anna
    VETERINARY CLINICAL PATHOLOGY, 2023, 52 (02) : 252 - 260
  • [10] ELECTROLYTE BALANCED HEPARIN MAY PRODUCE A BIAS IN THE MEASUREMENT OF IONIZED CALCIUM-CONCENTRATION IN SPECIMENS WITH ABNORMALLY LOW-PROTEIN CONCENTRATION
    LYON, ME
    GUAJARDO, M
    LAHA, T
    MALIK, S
    HENDERSON, PJ
    KENNY, MA
    CLINICA CHIMICA ACTA, 1995, 233 (1-2) : 105 - 113