Vital Sign Detection during Large-Scale and Fast Body Movements Based on an Adaptive Noise Cancellation Algorithm Using a Single Doppler Radar Sensor

被引:25
|
作者
Yang, Zi-Kai [1 ]
Shi, Heping [2 ]
Zhao, Sheng [1 ]
Huang, Xiang-Dong [3 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin 300072, Peoples R China
[2] Tianjin Univ Technol & Educ, Sch Automobile & Transportat, Tianjin 300222, Peoples R China
[3] Tianjin Univ, Sch Elect Informat Engn, Tianjin 300072, Peoples R China
关键词
continuous-wave Doppler radar; random body movement; vital sign detection; adaptive noise cancellation; new-type discrete cosine transform; INJECTION-LOCKED RADAR; HEART-RATE; REAL-TIME; COMPENSATION; TRANSFORM; SYSTEM; MOTION;
D O I
10.3390/s20154183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The non-contact detection of human vital signs (i.e., respiration rate (RR) and heartbeat rate (HR)) using a continuous-wave (CW) Doppler radar sensor has great potential for intensive care monitoring, home healthcare, etc. However, large-scale and fast random body movement (RBM) has been a bottleneck for vital sign detection using a single CW Doppler radar. To break this dilemma, this study proposed a scheme combining adaptive noise cancellation (ANC) with polynomial fitting, which could retrieve the weak components of both respiration and heartbeat signals that were submerged under serious RBM interference. In addition, the new-type discrete cosine transform (N-DCT) was introduced to improve the detection accuracy. This scheme was first verified using a numerical simulation. Then, experiments utilizing a 10-GHz Doppler radar sensor that was built from general-purpose radio frequency (RF) and communication instruments were also carried out. No extra RF/microwave components and modules were needed, and neither was a printed circuit board nor an integrated-chip design required. The experimental results showed that both the RR and HR could still be extracted during large-scale and fast body movements using only a single Doppler radar sensor because the RBM noises could be greatly eliminated by utilizing the proposed ANC algorithm.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 12 条
  • [1] Doppler Radar Vital Sign Detection with Random Body Movement Cancellation Based on Adaptive Phase Compensation
    Gu, Changzhan
    Wang, Guochao
    Inoue, Takao
    Li, Changzhi
    [J]. 2013 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (IMS), 2013,
  • [2] Doppler Vital Signs Detection in the Presence of Large-Scale Random Body Movements
    Lv, Qinyi
    Chen, Lei
    An, Kang
    Wang, Jun
    Li, Huan
    Ye, Dexin
    Huangfu, Jiangtao
    Li, Changzhi
    Ran, Lixin
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (09) : 4261 - 4270
  • [3] Deep Neural Network based Body Movement Cancellation for Doppler Radar Vital Sign Detection
    Gu, Changzhan
    Wang, Jian
    Lien, Jaime
    [J]. 2019 IEEE MTT-S INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2019), 2019,
  • [4] A Large-scale Movement Path Fitting Based Phase Compensation Algorithm for FMCW Radar Vital Sign Detection
    Sun, Li
    Bai, Ge
    Luo, Changhao
    Huang, Shauiming
    [J]. 2024 IEEE TOPICAL CONFERENCE ON WIRELESS SENSORS AND SENSOR NETWORKS, WISNET, 2024, : 37 - 40
  • [5] Tracking-Aided Respiration Detection Using Radar During Large-Scale Body Movements
    Ren, Wei
    Han, Huizi
    Chang, Shaoqiang
    Liu, Quanhua
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (15) : 17187 - 17199
  • [6] Body movement cancellation using adaptive filtering technology for radar-based vital sign monitoring
    Zhang, Li
    Ding, Chuanwei
    Zhou, Xudong
    Hong, Hong
    Li, Changzhi
    Zhu, Xiaohua
    [J]. 2020 IEEE RADAR CONFERENCE (RADARCONF20), 2020,
  • [7] A new method for vital sign detection using FMCW radar based on random body motion cancellation
    Fu, Shuai
    Ling, Ming
    Li, Zhenhua
    Pan, Long
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (06): : 617 - 632
  • [8] Remote Vital Signal Detection Using Ambient Noise Cancellation Based on Beam-Switching Doppler Radar
    Jang, Ah-Jung
    Lee, In-Seong
    Yang, Jong-Ryul
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [9] Single-Antenna Doppler Radars Using Self and Mutual Injection Locking for Vital Sign Detection With Random Body Movement Cancellation
    Wang, Fu-Kang
    Horng, Tzyy-Sheng
    Peng, Kang-Chun
    Jau, Je-Kuan
    Li, Jian-Yu
    Chen, Cheng-Chung
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2011, 59 (12) : 3577 - 3587
  • [10] Respiration Rate Measurement Under 1-D Body Motion Using Single Continuous-Wave Doppler Radar Vital Sign Detection System
    Tu, Jianxuan
    Hwang, Taesong
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (06) : 1937 - 1946