Variable Bandwidth Chopper Amplifier for Eddy-Current Non-Destructive Testing

被引:0
|
作者
Silva, Joao [1 ]
Oliveira, David [1 ]
Caetano, Diogo M. [1 ]
Rabuske, Taimur [1 ]
Fernandes, Jorge [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, INESC ID, Lisbon, Portugal
关键词
NDT; Eddy Currents; Magneto Resistors; TMR; TMJ; Low-Noise; Chopper; Pseudo Resistor;
D O I
10.3233/978-1-61499-767-2-187
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work focuses on an amplifier to be integrated in an Eddy Current (EC) Non-Destructive Testing (NDT) system presented in [1]. This system is designed for detection of superficial and internal flaws on conductive materials, using magnetoresistive (MR) sensors. The sensors can be biased with a DC+AC current to allow signal heterodyning. Biasing signal is analogically removed without the use of any digital circuit. Minimum working frequency is 1.5 Hz, allowing larger penetration depths. At such low frequencies, the amplifier presents large flicker (or 1/f) noise, which is mitigated using Chopper Stabilization [2]. The amplifier rejects DC and has a controllable pole frequency that can be tuned from 1.5 Hz to 1 Mhz. This tunability is achieved by implementing a novel tunable pseudo-resistor, to reduce large settling times when changing between sensors. The amplifier has a 12 nV/root Hz at 10 Hz with flicker corner frequency at 10 kHz and a noise floor of 4 nV/root Hz. Simulations were performed in AMS 0.35 mu m CMOS technology.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 50 条
  • [1] Eddy-current non-destructive testing - examples of application
    Dybiec, Czeslaw
    Wlodarczyk, Sylwia
    OCHRONA PRZED KOROZJA, 2010, 53 (03): : 67 - 74
  • [2] Evaluation of System Parameters for Eddy-Current Non-Destructive Testing
    Astakhov, V.
    Danilina, E.
    2017 2ND INTERNATIONAL URAL CONFERENCE ON MEASUREMENTS (URALCON), 2017, : 336 - 340
  • [3] PREDICTION OF EDDY-CURRENT SIGNALS FOR NON-DESTRUCTIVE TESTING OF CONDENSER TUBING
    PALANISAMY, R
    LORD, W
    IEEE TRANSACTIONS ON MAGNETICS, 1983, 19 (05) : 2213 - 2215
  • [4] Eddy-current non-destructive testing system for the determination of crack orientation
    Hamia, Rimond
    Cordier, Christophe
    Dolabdjian, Christophe
    NDT & E INTERNATIONAL, 2014, 61 : 24 - 28
  • [5] ADVANCES IN EDDY-CURRENT NON-DESTRUCTIVE EVALUATION
    Janousek, L.
    Gombarska, D.
    Capova, K.
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2008, 7 (1-2) : 318 - 321
  • [6] EDDY-CURRENT FLOWS AROUND CRACKS IN THIN PLATES FOR NON-DESTRUCTIVE TESTING
    MUKHERJEE, S
    MORJARIA, MA
    MOON, FC
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1982, 49 (02): : 389 - 395
  • [7] A non-destructive testing application solved with A-χ geometric eddy-current formulation
    Codecasa, Lorenzo
    Dular, Patrick
    Specogna, Ruben
    Trevisan, Francesco
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2010, 29 (06) : 1606 - 1615
  • [8] Microfabricated Eddy-Current Sensors for Non-Destructive Testing of the Micro Grinding Burn
    Khazi, Isman
    Kovacs, Andras
    Zahedi, Ali
    Mescheder, Ulrich
    Azarhoushang, Bahman
    2020 IEEE SENSORS, 2020,
  • [9] A geometrical theory for eddy-current non-destructive evaluation
    Harfield, N
    Bowler, JR
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1997, 453 (1961): : 1121 - 1152
  • [10] Design of a Lock-in Amplifier Integrated with a Coil System for Eddy-Current Non-Destructive Inspection
    Munoz, Fredy
    Miro, Jaime Valls
    Dissanayake, Gamini
    Thapane, Nalika
    Nguyen, Linh
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 1948 - 1953