A 3-D finite element study of effect of cortical bone thickness on compressive stress levels at the neck region of a dental implant.

被引:0
|
作者
AbuHammad, OA [1 ]
Harrison, A [1 ]
机构
[1] UNIV BRISTOL SCH DENT,BRISTOL,AVON,ENGLAND
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
引用
收藏
页码:1153 / 1153
页数:1
相关论文
共 50 条
  • [1] A 3-D finite element study of effect of alveolar bone resorption on compressive stress levels at the neck region of dental implants.
    Harrison, OAA
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1167 - 1167
  • [2] The effect of properties of bone on the stress levels around a dental implant. An fea study.
    AbuHammad, OA
    Harrison, A
    Watkinson, AC
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1167 - 1167
  • [3] Effect of Implant Diameter and Cortical Bone Thickness on Biomechanical Performance of Short Dental Implant-Supported Distal Cantilever: A Finite Element Study
    Muangsisied, Suthep
    Chantarapanich, Nattapon
    Veerasakul, Melvin Stanley
    Inglam, Samroeng
    ENGINEERING JOURNAL-THAILAND, 2021, 25 (02): : 175 - 182
  • [4] The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
    Robau-Porrua, Amanda
    Perez-Rodriguez, Yoan
    Soris-Rodriguez, Laura M.
    Perez-Acosta, Osmel
    Gonzalez, Jesus E.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 541 - 558
  • [5] Effect of the Number of Dental Implant Neck Threads in Contact with the Cortical Bone on Interface Stresses Using Finite Element Method
    Hassan, Mohammed Moustafa
    El-Wakad, Moahamed-Tarek
    Bakr, E. M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [6] Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
    Londono, J. J.
    Ramos, A.
    Correa, S.
    Mesnard, M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S178 - S179
  • [7] Finite element modelling of implant designs and cortical bone thickness on stress distribution in maxillary type IV bone
    Chou, I-Chiang
    Lee, Shyh-Yuan
    Wu, Ming-Chang
    Sun, Chia-Wei
    Jiang, Cho-Pei
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (05) : 516 - 526
  • [8] Effect of Short Dental Implant Material on Bone Stress: An In Vitro Finite Element Analysis
    Al Qahtani, Waleed M. S.
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1781 - 1786
  • [9] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876
  • [10] The effect of a hydroxyapatite-reinforced polyethylene stress distributor in a dental implant on compressive stress levels in surrounding bone
    Abu-Hammad, OA
    Harrison, A
    Williams, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (04) : 559 - 564