共 5 条
Quantification of activity by alpha-camera imaging and small-scale dosimetry within ovarian carcinoma micrometastases treated with targeted alpha therapy
被引:0
|作者:
Chouin, N.
[1
,2
]
Lindegren, S.
[2
]
Jensen, H.
[3
]
Albertsson, P.
[4
]
Back, T.
[2
]
机构:
[1] LUNAM Univ, AMaROC, F-44307 Nantes, France
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[3] Cyclotron & PET Unit, Copenhagen, Denmark
[4] Univ Gothenburg, Sahlgrenska Acad, Dept Oncol, Inst Clin Sci, Gothenburg, Sweden
来源:
关键词:
Neoplasm micrometastasis;
Astatine;
Ovarian neoplasm;
PARTICLE RADIOIMMUNOTHERAPY;
NUDE-MICE;
CANCER;
INTRAPERITONEAL;
MODEL;
ASTATINE-211;
ANTIBODIES;
AT-211;
CELLS;
VIVO;
D O I:
暂无
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Targeted alpha therapy (TAT) a promising treatment for small, residual, and micrometastatic diseases has questionable efficacy against malignant lesions larger than the a-particle range, and likely requires favorable intratumoral activity distribution. Here, we characterized and quantified the activity distribution of an alpha-particle emitter radiolabelled antibody within >100-mu m micrometastases in a murine ovarian carcinoma model. Nude mice bearing ovarian micrometastases were injected intra-peritoneally with At-211- MX35 (total injected activity 6 MBq, specific activity 650 MBq/mg). Animals were sacrificed at several time points, and peritoneal samples were excised and prepared for alpha-camera imaging. Spatial and temporal activity distributions within micrometastases were derived and used for small-scale dosimetry. We observed two activity distribution patterns: uniform distribution and high stable uptake (>100% IA/g at all time points) in micrometastases with no visible stromal compartment, and radial distribution (high activity on the edge and poor uptake in the core) in tumor cell lobules surrounded by fibroblasts. Activity distributions over time were characterized by a peak (140% IA/g at 4 h) in the outer tumor layer and a sharp drop beyond a depth of 50 pm. Small-scale dosirnetry was performed on a multi-cellular micrometastasis model, using time-integrated activities derived from the experimental data. With injected activity of 400 kBq, tumors exhibiting uniform activity distribution received <25 Gy (EUD=13 Gy), whereas tumors presenting radial activity distribution received mean absorbed doses of <8 Gy (EUD=5 Gy). These results provide new insight into important aspects of TAT, and may explain why micro- metastases >100 mu m might not be effectively treated by the examined regimen.
引用
收藏
页码:487 / 495
页数:9
相关论文