Aortic regurgitation after transcatheter aortic valve implantation of the edwards SAPIEN™ valve

被引:5
|
作者
Nielsen, Hans Henrik Moller [1 ]
Egeblad, Henrik [2 ]
Andersen, Henning Rud [2 ]
Thuesen, Leif [2 ]
Poulsen, Steen Hvitfeldt [2 ]
Klaaborg, Kaj-Erik [1 ]
Jakobsen, Carl-Johan [3 ]
Hjortdal, Vibeke Elisabeth [1 ]
机构
[1] Aarhus Univ Hosp, Dept Thorac & Cardiovasc Surg, Skejby, Denmark
[2] Aarhus Univ Hosp, Dept Cardiol, Skejby, Denmark
[3] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, Skejby, Denmark
关键词
aortic valve stenosis; prosthetic valve regurgitation; transcatheter aortic valve implantation; EUROPEAN ASSOCIATION; RECOMMENDATIONS; CARDIOLOGY; OUTCOMES; STENOSIS; SOCIETY;
D O I
10.3109/14017431.2012.731519
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction. Transcatheter aortic valve implantation (TAVI) is established as an attractive treatment option for high-risk patients with aortic valve stenosis. One concern is the high risk of prosthetic valve regurgitation. This study aimed to examine for potential preoperative risk factors for postprocedural transcatheter heart valve regurgitation and to quantify the risk, degree, and consequences of postprocedural regurgitation. Materials and methods. 100 consecutive patients who underwent femoral (n = 22) or transapical (n = 78) TAVI were retrospectively reviewed. Echocardiographic valve regurgitation and clinical parameters were analyzed over the first year after TAVI. Results. Seventy-five percent of all patients had prosthetic valve regurgitation. It was, however, only mild or absent in 64% of patients and did not require re-intervention in any of the patients in the series. The severity of the regurgitation appeared unchanged over the one-year follow-up period. Moderate to severe regurgitation was associated with significant yet stable dilatation of the left ventricle over one year and lesser NYHA class improvement three months after TAVI. Asymmetrical native valve calcification increased the risk of paravalvular regurgitation non-significantly. Conclusion. Transcatheter heart valve regurgitation seems to be mild in the majority of cases and unchanged over a 12 months follow-up period. While affecting left ventricular dimensions in moderate or severe cases, we observed no obvious undesirable consequences of the prosthetic valve regurgitation within the first year.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [1] Management of Paravalvular Regurgitation After Edwards SAPIEN Transcatheter Aortic Valve Replacement
    Martinez, Claudia A.
    Singh, Vikas
    O'Neill, Brian P.
    Alfonso, Carlos E.
    Bilsker, Martin S.
    Clark, Pedro Martinez
    Williams, Donald
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) : 300 - 311
  • [2] Edwards SAPIEN 3 Transcatheter Heart Valve Implantation in a Native Bicuspid Aortic Regurgitation
    Nagaraja, Vinayak
    Gunning, Mark
    Ratib, Karim
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (11) : S70 - S71
  • [3] Paravalvular aortic regurgitation after transcatheter aortic valve implantation with the Sapien 3 valve: impact of valve sizing, implantation height and valve calcification
    Alba, F. De Torres
    Kaleschke, G.
    Diller, G. P.
    Vormbrock, J.
    Feurle, M.
    Orwat, S.
    Radke, R.
    Safak, E.
    Stepper, W.
    Schmidt, R.
    Hellige, A.
    Deschka, H.
    Fischer, D.
    Reinecke, H.
    Baumgartner, H.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 749 - 749
  • [4] Aortic regurgitation after transcatheter aortic valve implantation
    Costopoulos, Charis
    Naganuma, Toru
    Latib, Azeem
    Colombo, Antonio
    [J]. EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (09) : 1089 - 1092
  • [5] Challenges in transcatheter valve treatment: aortic regurgitation after transcatheter aortic valve implantation
    Sinning, Jan-Malte
    Werner, Nikos
    Nickenig, Georg
    Grube, Eberhard
    [J]. EUROINTERVENTION, 2013, 9 : S72 - S76
  • [6] PATHOLOGY OF EDWARDS SAPIEN TRANSCATHETER AORTIC VALVE FOLLOWING IMPLANTATION IN HUMANS
    Yahagi, Kazuyuki
    Ladich, Elena
    Zarpak, Roya
    Sanchez, Oscar D.
    Koppara, Tobias
    Mori, Hiroyoshi
    Olson, Michelle
    Kolodgie, Frank
    Leon, Martin
    Joner, Michael
    Virmani, Renu
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1724 - A1724
  • [7] Single center experience with transcatheter aortic valve implantation using the Edwards SAPIEN™ Valve
    Nielsen, Hans Henrik Moller
    Thuesen, Leif
    Egeblad, Henrik
    Poulsen, Steen Hvitfeldt
    Klaaborg, Kaj-Erik
    Jakobsen, Carl-Johan
    Andersen, Henning Rud
    Hjortdal, Vibeke Elisabeth
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2011, 45 (05) : 261 - 266
  • [8] Transaortic Transcatheter Aortic Valve Implantation Using Edwards SAPIEN Valve: A Novel Approach
    Bapat, Vinayak
    Khawaja, Muhammed Z.
    Attia, Rizwan
    Narayana, Ashok
    Wilson, Karen
    Macgillivray, Kirsty
    Young, Christopher
    Hancock, Jane
    Redwood, Simon
    Thomas, Martyn
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (05) : 733 - 740
  • [9] Transapical-transcatheter aortic valve implantation using the Edwards SAPIEN 3 valve
    Useini, Dritan
    Schlomicher, Markus
    Beluli, Blerta
    Christ, Hildegard
    Ewais, Elias
    Haldenwang, Peter
    Patsalis, Polykarpos
    Moustafine, Vadim
    Bechtel, Matthias
    Strauch, Justus
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2021, 62 (06): : 609 - 617
  • [10] Proximal embolization of Edwards SAPIEN prosthesis in transcatheter aortic valve implantation
    Yuksel, Isa Oner
    Koklu, Erkan
    Arslan, Sakir
    Cagirci, Goksel
    Kucukseymen, Selcuk
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2016, 44 (01): : 75 - 78