Clinical and CT scan evaluation after direct defect repair in spondylolysis using segmental pedicular screw hook fixation

被引:0
|
作者
Pellisé, F [1 ]
Toribio, J [1 ]
Rivas, A [1 ]
García-Fontecha, C [1 ]
Bagó, J [1 ]
Villanueva, C [1 ]
机构
[1] Hosp Traumatol & Rehabil Vall Hebron, Unitat Estudi Patol Rajuis, Barcelona, Spain
来源
JOURNAL OF SPINAL DISORDERS | 1999年 / 12卷 / 05期
关键词
CT scan; lumbar spine; pars interarticularis; pedicular screw; spondylolysis; surgery; segmental fixation;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Direct defect repair using segmental pedicular screw hook fixation was carried out in nine patients with spondylolysis and a mean age of 24.2 years. One patient was fused 3 years after isthmic reconstruction. In the remaining eight patients, after a mean follow-up of 41 months (range, 12-78), three self-evaluation scales revealed a significant (p < 0.05) improvement in clinical status. Computed tomography scans were carried out in seven patients. There was bilateral bony union in two cases, in three pars healing was unilateral, and in two the isthmic defect persisted bilaterally. No correlation was observed between the status of the pars and follow-up. We conclude that repair of defects in spondylolysis may result in a favorable clinical outcome even when anatomic reconstruction of pars interarticularis is not successful.
引用
收藏
页码:363 / 367
页数:5
相关论文
共 18 条
  • [1] Repair of defects in spondylolysis by segmental pedicular screw hook fixation - A preliminary report
    Tokuhashi, Y
    Matsuzaki, H
    SPINE, 1996, 21 (17) : 2041 - 2045
  • [2] Biomechanical and clinical study on screw hook fixation after direct repair of lumbar spondylolysis
    赵剑
    刘璠
    施红光
    樊建
    赵卫东
    王友华
    蔡玉辉
    中华创伤杂志(英文版), 2006, (05) : 288 - 292
  • [3] Biomechanical and clinical study on screw hook fixation after direct repair of lumbar spondylolysis
    赵剑
    刘璠
    施红光
    樊建
    赵卫东
    王友华
    蔡玉辉
    Chinese Journal of Traumatology, 2006, (05) : 288 - 292
  • [4] Direct repair of spondylolysis using a new pedicle screw hook fixation:: Clinical and CT-assessed study -: An analysis of 19 patients
    Roca, J
    Iborra, M
    Cavanilles-Walker, JM
    Albertí, G
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 : S82 - S89
  • [5] Direct repair of defects in lumbar spondylolysis with a new pedicle screw hook fixation: clinical, functional and Ct-assessed study
    Felix Debusscher
    Serge Troussel
    European Spine Journal, 2007, 16 : 1650 - 1658
  • [6] Direct repair of defects in lumbar spondylolysis with a new pedicle screw hook fixation: clinical, functional and Ct-assessed study
    Debusscher, Felix
    Troussel, Serge
    EUROPEAN SPINE JOURNAL, 2007, 16 (10) : 1650 - 1658
  • [7] Direct repair of spondylolysis by TSRH's Hook plus screw fixation and bone grafting: biomechanical study and clinical report
    Fan, Jian
    Yu, Guang-rong
    Liu, Fan
    Zhao, Jian
    Zhao, Wei-dong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (02) : 209 - 215
  • [8] Direct repair of spondylolysis by TSRH’s Hook plus screw fixation and bone grafting: biomechanical study and clinical report
    Jian Fan
    Guang-rong Yu
    Fan Liu
    Jian Zhao
    Wei-dong Zhao
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 209 - 215
  • [9] MODIFIED REPAIR OF A DEFECT IN SPONDYLOLYSIS OR MINIMAL SPONDYLOLISTHESIS BY PEDICLE SCREW, SEGMENTAL WIRE FIXATION, AND BONE-GRAFTING
    SALIB, RM
    PETTINE, KA
    SPINE, 1993, 18 (04) : 440 - 443
  • [10] Clinical Results and Functional Outcomes After Direct Intralaminar Screw Repair of Spondylolysis
    Menga, Emmanuel N.
    Kebaish, Khaled M.
    Jain, Amit
    Carrino, John A.
    Sponseller, Paul D.
    SPINE, 2014, 39 (01) : 104 - 110