Development of a Non-Contact Angular Transducer

被引:0
|
作者
Farcas, C. [1 ]
Cosma, A. [1 ]
Palaghita, N. [1 ]
Grama, A. [1 ]
Gabor, M. S. [2 ]
Tiusan, C. [2 ]
机构
[1] Tech Univ Cluj Napoca, Dept Appl Elect, Cluj Napoca, Romania
[2] Tech Univ Cluj Napoca, Ctr Superconduct Spintron & Surface Sci, Dept Chem & Phys, Cluj Napoca, Romania
关键词
spin-valves; GMR angular sensor; design of electronic circuits; non-contact transducer; MAGNETORESISTANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Paper presents the design of a non-contact angular transducer. We used a GMR-based angular sensor developed in the Center for Superconductivity, Spintronics and Surface Science from Technical University of Cluj-Napoca. The GMR sensor is an application of spin-valves. Magnetoresistance is dependent by angle between magnetic field and magnetic moments in a ferromagnetic material in GMR sensor. We realized a laboratory setup that measure the resistance of sensor. This resistance is strongly dependent by angle between magnetic field applied to the sensor and magnetic moments in material. This dependence is a non-linear one, but the software linearized it.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [1] Contact and non-contact compound thermometry transducer
    Yi Qi Yi Biao Xue Bao, 5 (470-474):
  • [2] Non-contact transducer improves foundry operations
    Design News (Boston), 1994, 49 (10):
  • [3] Analysis of a non-contact magnetoelastic torque transducer
    Andreescu, R.
    Spellman, B.
    Furlani, E. P.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2008, 320 (12) : 1827 - 1833
  • [4] Flexural Transducer Arrays for Industrial Non-Contact Applications
    Eriksson, T. J. R.
    Ramadas, S. N.
    Unger, A.
    Hoffman, M.
    Kupnik, M.
    Dixon, S. M.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [5] Development of Non-contact Electroscope
    Zhou, Momo
    Li, Chunmao
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [6] Social development in contact and non-contact sports
    Baledi, Reza
    Mohammadi, Farzad
    Asefirad, Arash
    4TH WORLD CONFERENCE ON EDUCATIONAL SCIENCES (WCES-2012), 2012, 46 : 347 - 349
  • [8] Ultrasonic field modelling for arbitrary non-contact transducer source
    Jian, X
    Dixon, S
    Edwards, RS
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 515 - 519
  • [9] NON-CONTACT DIGITAL TRANSDUCER ADVANCES NET WEIGHT TECHNOLOGY
    不详
    FOOD ENGINEERING, 1974, 46 (12): : 88 - 88
  • [10] Residual strain effects on a non-contact magnetoelastic torque transducer
    Andreescu, R.
    Spellman, B.
    Furlani, E. P.
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2010, 32 (03) : 183 - 193