Dose Calculation Variations in AAA and Acuros-XB for Pancreatic Cancer Treatment Planning

被引:0
|
作者
Harpool, K. [1 ]
Schnell, E. [1 ]
Herman, T. [1 ]
Ahmad, S. [1 ]
Herman, T. De La Fuente [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:2927 / 2927
页数:1
相关论文
共 50 条
  • [1] Comparison of AAA and Acuros XB Dose Calculation Algorithms for SRS
    Yeh, F.
    Adamson, J.
    Wang, Z.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E725 - E725
  • [2] The Clinical Implementation and Dosimetric Comparison of Acuros-XB and AAA for Stereotactic Body Radiotherapy for Lung Cancer
    Sullivan, R.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E493 - E494
  • [3] Clinical Implementation of Acuros-XB From AAA for Breast: Changes in Plan Characteristics
    Conroy, L.
    Guebert, A.
    Weppler, S.
    Alghamdi, M.
    Conway, J.
    Harper, L.
    Phan, T.
    Olivotto, I.
    Smith, W.
    Quirk, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2929 - 2929
  • [4] Acuros XB and AAA Dose Calculation Accuracy for Small Fields in RapidArc Treatments
    Fogliata, A.
    Nicolini, G.
    Clivio, A.
    Vanetti, E.
    Cozzi, L.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Dose calculation validation of AAA and Acuros XB algorithms in presence of titanium spinal implants
    Tait, J.
    Williams, T.
    Stacey, C. F.
    Hussein, M.
    Clark, C. H.
    Johnson, U.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1364 - S1365
  • [6] Comparison of Acuros XB, AAA and PBC dose calculations for clinical treatment plans
    Jones, C.
    Wells, E.
    Meehan, C.
    Trouncer, R.
    Banks, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S791 - S791
  • [7] Evaluating small field dosimetry with the Acuros XB (AXB) and analytical anisotropic algorithm (AAA) dose calculation algorithms in the eclipse treatment planning system
    Behinaein, Sepideh
    Osei, Ernest
    Darko, Johnson
    Charland, Paule
    Bassi, Dylan
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (04) : 353 - 364
  • [8] Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc® stereotactic treatments
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6228 - 6237
  • [9] Dosimetric and Radiobiological Variations in Different Dose Calculation Grid Sizes Between Acuros XB and AAA Algorithms for Prostate VMAT Plans
    Kim, K.
    Chung, J.
    Kang, S.
    Kang, S.
    Kim, J.
    Eom, K.
    Song, C.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E301 - E301
  • [10] From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium
    Jackson M. Zifodya
    Cameron H. C. Challens
    Wen-Long Hsieh
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 431 - 439