The Failure Finite Element Analysis of Pump Collision with Valve in the Oil Well Pump

被引:1
|
作者
Wang, Suling [1 ]
Zhang, Ying [1 ]
Bai, Nanyang [1 ]
Cai, Yumiao [1 ]
机构
[1] Northeast Petr Univ, Coll Mech Sci & Engn, Daqing 163318, Heilongjiang, Peoples R China
关键词
Pump; Valve ball; Valve housing; Impact; Failure;
D O I
10.4028/www.scientific.net/AMR.690-693.3112
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The three element drive pump failure was the main reason to reduce inspection cycle of the pump. In this paper, a law of pump valve motion in one stroke was acquired through the establishment of the motion equations of the pump valve in the oil well pump, by making it as the pump valve boundary conditions and using ANSYS / LS-DYNA software, the stress state of the valve housing under the conditions of pump valve impact on the valve cover was analyzed, and as the calculation was shown, under the same conditions, the groove valve cover has the stronger impact than the extended grooved valve housing. The inspection cycle of groove valve housing was 457 days shorter than the extended grooved valve cover according to the theory of the fatigue life, therefore, the extended valve housing can effectively extend the check period.
引用
收藏
页码:3112 / 3115
页数:4
相关论文
共 50 条
  • [1] Force analysis and fatigue life evaluation of oil well pump valve cover
    Yuan, Dexin
    Wang, Hanxiang
    Liu, Yanxin
    Gong, Zhaoyang
    AIP ADVANCES, 2023, 13 (03)
  • [2] Failure Analysis of a Jacking Oil Pump
    Ghosh, S. J.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2007, 7 (01) : 23 - 27
  • [3] Finite Element Analysis of Pump Casing for Triplex Plunger Pump Based on Abaqus
    He, Xia
    Huang, Chongjun
    Liu, Qingyou
    Liu, Yang
    Tian, Jiayu
    MATERIALS PROCESSING TECHNOLOGY, 2011, 337 : 219 - +
  • [4] FAILURE ANALYSIS Root Cause Failure Analysis of a Boiler Feed Pump Main Oil Pump Gear
    Mobin, M.
    Malik, A. U.
    Al-Muaili, Fahd
    Al-Hajri, M.
    MATERIALS PERFORMANCE, 2013, 52 (02) : 52 - 54
  • [5] Finite element analysis for adhesive failure of progressive cavity pump with stator of even thickness
    Chen, Jie
    Wang, FengShan
    Shi, GuoCheng
    Cao, Gang
    He, Yan
    Ge, WeiTao
    Liu, He
    Wu, HengAn
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2015, 125 : 146 - 153
  • [6] EVALUATION OF MECHANICAL LOADING OF A TRILEAFLET POLYURETHANE BLOOD PUMP VALVE BY FINITE-ELEMENT ANALYSIS
    KNIERBEIN, B
    MOHRMATUSCHEK, U
    RECHLIN, M
    REUL, H
    RAU, G
    MICHAELI, W
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (05): : 307 - 315
  • [7] Finite element analysis of wear for centrifugal slurry pump
    Dong Xing
    Zhang Hai-lu
    Wang Xin-yong
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MINING SCIENCE & TECHNOLOGY (ICMST2009), 2009, 1 (01): : 1532 - 1538
  • [8] Finite element analysis of cooling water pump shaft
    Shaw J.
    World Pumps, 2022, 2022 (657) : 30 - 32
  • [9] Finite Element Analysis on the Blade Structure of Centrifugal Pump
    Wu Lan-Ying
    Wang Yan-Lin
    MATERIALS PROCESSING TECHNOLOGIES, PTS 1 AND 2, 2011, 154-155 : 1748 - +
  • [10] Dynamic finite element analysis of a micro lobe pump
    Huber, N
    Aktaa, J
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2003, 9 (6-7): : 465 - 469