Computing the spatial QRS-T angle using reduced electrocardiographic lead sets

被引:1
|
作者
Guldenring, Daniel [1 ]
Finlay, Dewar D. [1 ]
Bond, Raymond R. [1 ]
Kennedy, Alan [1 ]
McLaughlin, James [1 ]
Galeotti, Loriano [2 ]
Strauss, David G. [2 ]
机构
[1] Univ Ulster, Jordanstown Campus,Shore Rd, Newtownabbey, Antrim, North Ireland
[2] US FDA, Off Sci & Engn Labs, CDRH, Silver Spring, MD USA
关键词
Linear lead transformations; Estimation of the Frank VCG; Derivation of the Frank VCG; Spatial QRS-T angle; Mason-Likar; 12-lead; ECG; Monitoring; 12-LEAD ELECTROCARDIOGRAM; VENTRICULAR GRADIENT; VECTORCARDIOGRAM; MATRIX; SYSTEM; ECG;
D O I
10.1016/j.jelectrocard.2016.07.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 'spatial QRS-T angle' (SA) is frequently determined using linear lead transformation matrices that require the entire 12-lead electrocardiogram (ECG). While this approach is adequate when using 12-lead ECG data that is recorded in the resting supine position, it is not optimal in monitoring applications. This is because maintaining a good quality recording of the complete 12-lead ECG in monitoring applications is difficult. In this research, we assessed the differences between the 'gold standard' SA as determined using the Frank VGG and the SA as determined using different reduced lead systems (RLSs). The random error component (span of the Bland-Altman 95% limits of agreement) of the differences between the 'gold standard' SA and the SA values based upon the different RLSs was quantified. This was performed for all 62 RLSs that can be constructed from Mason-Likar (ML) limb leads I, II and all possible precordial lead subsets that contain between one and five of the precordial leads VI to V6. The RLS with the smallest lead set size that produced SA estimates of a quality similar to what is achieved using the ML 12-lead ECG was based upon ML limb leads I, II and precordial leads V1, V3 and V6. The random error component (mean [95% confidence interval]) associated with this RLS and the ML 12-lead ECG were found to be 40.74 [35.56 degrees-49.29 degrees] and 39.57 degrees [33.78 degrees-45.70 degrees], respectively. Our findings suggest that a RLS that is based upon the ML limb leads I and II and the three best precordial leads can yield SA estimates of a quality similar to what is achieved when using the complete ML 12-lead ECG. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:794 / 799
页数:6
相关论文
共 50 条
  • [1] Deep-Learning-Based Estimation of the Spatial QRS-T Angle from Reduced-Lead ECGs
    Rodrigues, Ana Santos
    Augustauskas, Rytis
    Lukosevicius, Mantas
    Laguna, Pablo
    Marozas, Vaidotas
    [J]. SENSORS, 2022, 22 (14)
  • [2] The Spatial QRS-T Angle: Implications in Clinical Practice
    Voulgari, Christina
    Pagoni, Stamatina
    Tesfaye, Solomon
    Tentolouris, Nicholas
    [J]. CURRENT CARDIOLOGY REVIEWS, 2013, 9 (03) : 197 - 210
  • [3] THE NORMAL SPATIAL QRS-T ANGLE OF THE ORTHOGONAL VECTORCARDIOGRAM
    BALL, MF
    PIPBERGER, HV
    [J]. AMERICAN HEART JOURNAL, 1958, 56 (04) : 611 - 615
  • [4] Electrocardiographic Frontal Qrs-T Angle is Independently Associated With Panic Disorder
    Yilmaz, Mucahid
    Yilmaz, Seda
    [J]. INTERNATIONAL JOURNAL OF PSYCHIATRY IN MEDICINE, 2024, 59 (02): : 167 - 181
  • [5] Elevated blood pressure and electrocardiographic frontal T axis and spatial QRS-T angle changes in postmenopausal women
    Atsma, Femke
    Bartelink, Marie-Louise E. L.
    van der Schouw, Yvonne T.
    Kors, Jan A.
    Grobbee, Diederick E.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2008, 41 (04) : 360 - 364
  • [6] STUDIES ON THE QRS-T ANGLE
    HELM, RA
    FOWLER, NO
    [J]. AMERICAN HEART JOURNAL, 1953, 46 (02) : 229 - 236
  • [7] QRS-T Angle: A Review
    Oehler, Andrew
    Feldman, Trevor
    Henrikson, Charles A.
    Tereshchenko, Larisa G.
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2014, 19 (06) : 534 - 542
  • [8] The relation of blood lead and QRS-T angle in American adults
    Jing, Jin
    Thapa, Susan
    Delhey, Leanna
    Abouelenein, Saly
    Morad, Wesam
    Delongchamp, Robert
    Faramawi, Mohammed F.
    [J]. ARCHIVES OF ENVIRONMENTAL & OCCUPATIONAL HEALTH, 2019, 74 (05) : 287 - 291
  • [9] The spatial QRS-T angle as a marker of ventricular repolarisation in hypertension
    P Dilaveris
    E Gialafos
    A Pantazis
    A Synetos
    F Triposkiadis
    J Gialafos
    [J]. Journal of Human Hypertension, 2001, 15 : 63 - 70
  • [10] Sleep-disordered breathing and electrocardiographic QRS-T angle: The MESA study
    Kwon, Younghoon
    Misialek, Jeffrey R.
    Duprez, Daniel
    Jacobs, David R., Jr.
    Alonso, Alvaro
    Heckbert, Susan R.
    Zhao, Ying Y.
    Redline, Susan
    Soliman, Elsayed Z.
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2018, 23 (06)