Uncertainty evaluation of reliability of safety grade decay heat removal system of Indian prototype fast breeder reactor

被引:2
|
作者
Kumawat, H. L. [1 ]
Singh, Om Pal [1 ]
Munshi, Prabhat [1 ]
机构
[1] Indian Inst Technol, Nucl Engn & Technol Programme, Kanpur 208016, Uttar Pradesh, India
关键词
Uncertainty analysis; Safety grade decay heat removal system; Prototype fast breeder reactor; Fault tree; Reliability analysis;
D O I
10.1016/j.anucene.2013.05.028
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Deterministic and probabilistic safety assessment of nuclear power reactor technology is very important in assuring that the design is robust and safety systems perform as per requirement. The parameters required as input data for such analysis have uncertainties associated with them. Their impact is to be assessed on the results obtained for such analyses and it affects the overall decision making process. Safety Grade Decay Heat Removal System (SGDHRS) is one of the safety systems in fast breeder reactors and itremoves decay heat after reactor shutdown. It is a critical safety system; hence failure frequency for SGDHR is targeted to be less than 1.0 x 10(-7) per reactor year. By bringing diversity in some of the components of SGDHRS, such as sodium-to-sodium decay heat exchanger (DHX), sodium to air heat exchanger (AHX) and valves, one can achieve the targeted low failure frequency of SGDHRS. We perform uncertainty analysis of the reliability of such SGDHRS here. Uncertainty in failure rate (of components of SGDHRS) is assumed to follow the log-normal distribution with error factor of three. Monte Carlo method of sampling is used in MATLAB environment. Results are obtained in terms of mean, median and standard deviation values of failure frequency. Percentile and confidence interval analysis of mean values are also obtained. These provide 95 and 98 percentile and confidence interval values of 98%, 99% and 99.8%. It is found that error factor of failure frequency of SGDHRS is found to be less than 3 in all the cases except the one in which DHX, AHX and Valves are designed with diversity in design. It is to be noted here that error factor of all input parameters distribution is taken as 3. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 50 条
  • [1] Reliability analysis of safety grade decay heat removal system of Indian prototype fast breeder reactor
    Arul, AJ
    Kumar, CS
    Athmalingam, S
    Singh, OP
    Rao, KS
    ANNALS OF NUCLEAR ENERGY, 2006, 33 (02) : 180 - 188
  • [2] Experimental evaluation of safety grade decay heat removal in prototype fast breeder reactor
    Vinod, V.
    Krishnakumar, S.
    Punniyamoorthy, R.
    Vijayakumar, G.
    Chandramouli, S.
    Padmakumar, G.
    Nashine, B. K.
    Rajan, K. K.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 265 : 1057 - 1065
  • [3] Experimental studies in water for safety grade decay heat removal of prototype fast breeder reactor
    Mente, V. M.
    Pandey, G. K.
    Banerjee, I.
    Kumar, S. Ajesh
    Padmakumar, G.
    Rajan, K. K.
    ANNALS OF NUCLEAR ENERGY, 2014, 65 : 114 - 121
  • [4] Uncertainty evaluation of reliability of shutdown system of a medium size fast breeder reactor
    Zeliang, Chireuding
    Singh, Om Pal
    Munshi, Prabhat
    NUCLEAR ENGINEERING AND DESIGN, 2016, 308 : 283 - 296
  • [5] Functional reliability analysis of Safety Grade Decay Heat Removal System of Indian 500 MWe PFBR
    Mathews, T. Sajith
    Ramakrishnan, M.
    Parthasarathy, U.
    Arul, A. John
    Kumar, C. Senthil
    NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (09) : 2369 - 2376
  • [6] Weapon-Grade Plutonium Production Potential in the Indian Prototype Fast Breeder Reactor
    Glaser, Alexander
    Ramana, M. V.
    SCIENCE & GLOBAL SECURITY, 2007, 15 (02) : 85 - 105
  • [7] RELIABILITY ANALYSIS OF DECAY HEAT REMOVAL SYSTEM OF A 1000-MW(E) GAS-COOLED FAST BREEDER REACTOR
    BITTERMANN, D
    WEHLING, J
    NUCLEAR TECHNOLOGY, 1977, 32 (03) : 247 - 256
  • [8] Safety consideration for prototype fast breeder reactor "Monju"
    Kani, Y
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 2003, 45 (03): : 190 - 194
  • [9] Integration of functional reliability analysis with hardware reliability: An application to safety grade decay heat removal system of Indian 500 MWe PFBR
    Mathews, T. Sajith
    Arul, A. John
    Parthasarathy, U.
    Kumar, C. Senthil
    Ramakrishnan, M.
    Subbaiah, K. V.
    ANNALS OF NUCLEAR ENERGY, 2009, 36 (04) : 481 - 492
  • [10] Comparison of life of two types of decay heat exchangers used in prototype fast breeder reactor
    S. Jalaldeen
    R. Srinivasan
    P. Selvaraj
    P. Chellapandi
    Transactions of the Indian Institute of Metals, 2010, 63 : 647 - 651