Dynamic Offset Correction of Electromagnetic Flowmeters

被引:21
|
作者
Linnert, Michael A. [1 ]
Mariager, Simon O. [2 ]
Rupitsch, Stefan J. [1 ]
Lerch, Reinhard [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Chair Sensor Technol, D-91052 Erlangen, Germany
[2] Endress Hauser Flowtec AG, CH-4153 Reinach, Switzerland
关键词
Accuracy; data fusion; electromagnetic flowmeter (EMF); energy consumption; kalman filter; signal processing; state space; FLOW MEASUREMENT; METER; COIL;
D O I
10.1109/TIM.2018.2880942
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This contribution addresses the electrochemical voltage drift of electromagnetic flowmeters. We will extend the conventional discrete time alternating field method to continuous operation. A Kalman filter, based on a state space model of the sensor, will be developed to separate the flow-proportional signal from the noisy voltage drift of the electrodes. The new algorithm facilitates the processing of flow information rarely used today, i.e., longer intervals of the electrode voltage during times of stable magnetic field. The actually processed time interval of the electrode signal will be extended considerably. Thereby, a lower energy consumption and an increased accuracy can be achieved. The measurement error of the new method will be demonstrated to be less addicted to temporal flow variations. Measurements show a similar accuracy, but with a significantly reduced energy demand. A prototype with a field offset provided by permanent magnets is set up to evaluate its energy consumption. Offline signal processing predicts an 80% lower power demand compared to conventional flowmeters.
引用
收藏
页码:1284 / 1293
页数:10
相关论文
共 50 条
  • [1] ZERO OFFSET IN ELECTROMAGNETIC FLOWMETERS
    MONTGOMERY, GD
    SCHER, AM
    CORBIN, LV
    AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (01): : H157 - H161
  • [2] Dynamic Offset Correction of Electromagnetic Flow Meters
    Linnert, Michael A.
    Mariager, Simon O.
    Rupitsch, Stefan J.
    Lerch, Reinhard
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 674 - 679
  • [3] DYNAMIC CALIBRATION OF ELECTROMAGNETIC FLOWMETERS
    HILL, RD
    ZAPOL, WM
    FEDERATION PROCEEDINGS, 1981, 40 (03) : 519 - 519
  • [4] TECHNIQUE FOR DYNAMIC CALIBRATION OF ELECTROMAGNETIC FLOWMETERS
    MESHCHERSKII, EL
    MELKUMYANTS, AM
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1981, 92 (07) : 1005 - 1007
  • [5] ELECTRONIC DYNAMIC CALIBRATION OF ELECTROMAGNETIC FLOWMETERS
    GOODMAN, AH
    JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) : 933 - &
  • [7] Comparison of methods for the dynamic calibration of electromagnetic flowmeters
    Cave, F.D.
    Franklin, J.
    Patel, P.L.
    Medical and Biological Engineering and Computing, 1978, 16 (01): : 51 - 58
  • [8] Factors affecting the dynamic performance of electromagnetic flowmeters
    Sanderson, ML
    MEASUREMENT & CONTROL, 2003, 36 (09): : 270 - 274
  • [9] DYNAMIC TESTING OF ELECTROMAGNETIC FLOWMETERS BY MECHANICAL AND ELECTRONIC METHODS
    HAINSWORTH, R
    LEDSOME, JR
    SNOW, HM
    JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (04) : 469 - +
  • [10] ELECTROMAGNETIC FLOWMETERS
    不详
    MEASUREMENTS & CONTROL, 1995, (170): : 167 - 172