Hydrogen gas (H2) detection plays an important role in many fields. With the continuous demand and development of clean energy, it is urgent to study new hydrogen gas sensors for stable and accurate H2 detection. The purpose of this research is to develop a new H2 sensor based on the resonant photoacoustic (PA) cell as the sensing element. The sensi-tivity of the resonant PA cell to the resonant frequency is sufficiently utilized. The opti-mization of its resonance frequency was investigated minutely for the H2 sensor. Detection utilizes resonance frequency differences between H2 and air as a sensing mechanism. The resonance frequency tracking is adopted and implemented by the field-programmable gate array (FPGA) device. The minimum detection limit of about 74 ppm for H2 has been demonstrated by preliminary experiments. The response time of the sensor is about 5 s. This sensor detects concentrations ranging from 74 ppm to 100% in 1 atm. The preliminary test result shows that the H2 sensor based on this structure has a larger application perspective.(c) 2022 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:35940 / 35946
页数:7
相关论文
共 50 条
  • [1] Modeling of a cylindrical resonant photoacoustic cell for high sensitive gas detection
    Huang, Qi
    Zhou, Sheng
    He, Tianbo
    Li, Jingsong
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2021, 63 (10) : 2528 - 2534
  • [2] Miniaturized resonant photoacoustic cell of inclined geometry for trace-gas detection
    Gorelik, A. V.
    Ulasevich, A. L.
    Nikonovich, F. N.
    Zakharich, M. P.
    Firago, V. A.
    Kazak, N. S.
    Starovoitov, V. S.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (02): : 283 - 289
  • [3] Design and characteristics of a differential Helmholtz resonant photoacoustic cell for infrared gas detection
    Zeninari, V
    Kapitanov, VA
    Courtois, D
    Ponomarev, YN
    INFRARED PHYSICS & TECHNOLOGY, 1999, 40 (01) : 1 - 23
  • [4] Miniaturized resonant photoacoustic cell of inclined geometry for trace-gas detection
    A. V. Gorelik
    A. L. Ulasevich
    F. N. Nikonovich
    M. P. Zakharich
    V. A. Firago
    N. S. Kazak
    V. S. Starovoitov
    Applied Physics B, 2010, 100 : 283 - 289
  • [5] Design and characteristics of a differential Helmholtz resonant photoacoustic cell for infrared gas detection
    Zeninari, V.
    Kapitanov, V.A.
    Courtois, D.
    Ponomarev, Yu.N.
    Infrared Physics and Technology, 1999, 40 (01): : 1 - 23
  • [7] Miniature 3D-printed resonant photoacoustic cell for flowing gas detection
    Zhang, Guangyin
    Chen, Ke
    Guo, Min
    Li, Chenxi
    Xu, Lin
    Wang, Nan
    Zhao, Xinyu
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 341
  • [8] Geometrical optimization of a longitudinal resonant photoacoustic cell for sensitive and fast trace gas detection
    Bijnen, FGC
    Reuss, J
    Harren, FJM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08): : 2914 - 2923
  • [9] All-optical non-resonant photoacoustic spectroscopy for multicomponent gas detection based on aseismic photoacoustic cell
    Fu, Lujun
    Lu, Ping
    Pan, Yufeng
    Zhong, Yi
    Sima, Chaotan
    Wu, Qiang
    Zhang, Jiangshan
    Cui, Lingzhi
    Liu, Deming
    PHOTOACOUSTICS, 2023, 34
  • [10] Resonant photoacoustic detection of trace gas with DFB diode laser
    Li, Jingsong
    Gao, Xiaoming
    Fang, Li
    Zhang, Weijun
    Cha, Hyungki
    OPTICS AND LASER TECHNOLOGY, 2007, 39 (06): : 1144 - 1149