Micromachined Arch-type cantilever as high sensitivity uncooled infrared detector

被引:9
|
作者
Ivanova, K [1 ]
Ivanov, T [1 ]
Rangelow, IW [1 ]
机构
[1] Univ Kassel, Inst Microstruct Technol & Analyt, D-34132 Kassel, Germany
来源
关键词
D O I
10.1116/1.2134721
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we discuss an uncooled infrared (IR) detector based on an "arch-type" design realized with advanced microelectromechanical systems technology. Bimaterial microcantilevers undergo bending as their temperature changes due to the absorption of infrared photons. The bending is proportional to dissimilar thermal expansion of the two different materials composing the cantilever. We select the most optimal combination of materials used commonly in the micromachining technology resulting in highest bimaterial effect. Well known SU8 negative resist is one promising candidate having high thermal expansion coefficient (alpha = 52 x 10(-6)/K), and relatively low thermal conductivity (0.2 W/m K). Creating a micromechanical "arch" shaped cantilever a differential stress is induced due to different thermal expansion of middle beam formed from the SU8-film. Moreover, we fabricate a design microcantilever IR detector that consists two unique skills: (i) a Si/SU8 bimaterial system as material combination with beneficial bimaterial effect and (ii) tiny silicon "arch" shaped loop which includes two beams for piezoresistive detection of the bending. (c) 2005 American Vacuum Society.
引用
收藏
页码:3153 / 3157
页数:5
相关论文
共 50 条
  • [1] ARCH-type micro-cantilever FPA for uncooled IR detection
    Steffanson, M.
    Gorovoy, K.
    Ramkiattisak, V.
    Ivanov, T.
    Krol, J.
    Hartmann, H.
    Rangelow, I. W.
    [J]. MICROELECTRONIC ENGINEERING, 2012, 98 : 614 - 618
  • [2] A Bulk Micromachined Cantilever Array for Uncooled Infrared Imaging
    Yi, Yuliang
    Ma, Shenglin
    Yu, Xiaomei
    Liu, Ming
    Liu, Xiaohua
    [J]. MicroNano2008-2nd International Conference on Integration and Commercialization of Micro and Nanosystems, Proceedings, 2008, : 129 - 132
  • [3] Research of High Sensitivity Uncooled Infrared Detector Array
    Zhang, Ping-chuan
    Zhang, Bo
    [J]. 3RD INTERNATIONAL PHOTONICS AND OPTOELECTRONICS MEETINGS (POEM 2010), 2011, 276
  • [4] A Cantilever-Type Uncooled Infrared Detector With High Fill-Factor and Low-Noise Characteristic
    Kwon, Il Woong
    Son, Hyuck Jun
    Kim, Dong Soo
    Hwang, Chi Ho
    Lee, Yong Soo
    Yu, Byung-Gon
    Lee, Hee Chul
    [J]. IEEE ELECTRON DEVICE LETTERS, 2009, 30 (06) : 635 - 637
  • [5] Design and fabrication of micro-cantilever uncooled infrared detector
    Liu, HT
    Chen, YP
    Liang, PZ
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 25 (01) : 46 - 49
  • [6] Analysis of Optical Readout Sensitivity for Uncooled Infrared Detector
    Cheng Teng
    Zhang Qing-Chuan
    Jiao Bin-Bin
    Chen Da-Peng
    Wu Xiao-Ping
    [J]. CHINESE PHYSICS LETTERS, 2009, 26 (12)
  • [7] HIGH-SPEED UNCOOLED INFRARED DETECTOR
    BENDITSKII, AA
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (04) : 956 - 957
  • [8] Cavity-type metasurface uncooled infrared detector
    Yang, Jun
    Yang, Chun-Li
    Fang, Hui
    Yuan, Jun
    Yan, Shan-Ru
    Li, Hua-Ying
    Li, Bing-Zhe
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2024, 43 (05) : 621 - 627
  • [9] A novel micromachined uncooled infrared detector employing a-Si:H TFT as thermosensitive element
    Dong, L
    Liu, LT
    Yue, RF
    [J]. SEMICONDUCTOR OPTOELECTRONIC DEVICE MANUFACTURING AND APPLICATIONS, 2001, 4602 : 344 - 349
  • [10] High sensitivity uncooled microcantilever infrared imaging arrays
    Hunter, SR
    Amantea, RA
    Goodman, LA
    Kharas, DB
    Gershtein, S
    Matey, JR
    Perna, SN
    Yu, Y
    Maley, N
    White, LK
    [J]. INFRARED TECHNOLOLGY AND APPLICATIONS XXIX, 2003, 5074 : 469 - 480