Near-infrared fluorescence imaging to facilitate super-selective arterial clamping during zero-ischaemia robotic partial nephrectomy

被引:90
|
作者
Borofsky, Michael S. [1 ]
Gill, Inderbir S. [2 ]
Hemal, Ashok K. [3 ]
Marien, Tracy P. [1 ]
Jayaratna, Isuru [2 ]
Krane, Louis S. [3 ]
Stifelman, Michael D. [1 ]
机构
[1] NYU, Langone Med Ctr, Dept Urol, New York, NY USA
[2] Univ So Calif, Inst Urol, Los Angeles, CA USA
[3] Wake Forest Baptist Med Ctr, Dept Urol, Winston Salem, NC USA
关键词
kidney; robotic; partial nephrectomy; zero-ischaemia; fluorescence; LAPAROSCOPIC PARTIAL NEPHRECTOMY; TUMORS;
D O I
10.1111/j.1464-410X.2012.11490.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective To describe a novel technique of eliminating renal ischaemia during robotic partial nephrectomy (RPN) using near-infrared fluorescence (NIRF) imaging. Patients and Methods Over an 8-month period (March 2011 to November 2011), 34 patients were considered for zero-ischaemia RPN using the da Vinci NIRF system. Targeted tertiary/higher-order tumour-specific branches were controlled with robotic bulldog(s) or neurosurgical aneurysm micro-bulldog(s). Indocyanine green dye was given, and NIRF imaging used to confirm super-selective ischaemia, defined as darkened tumour/peri-tumour area with green fluorescence of remaining kidney. Matched pair analysis was performed by matching each patient undergoing zero-ischaemia RPN (n = 27) to a previous conventional RPN (n = 27) performed by the same surgeon. Results Of 34 patients, 27 (79.4%) underwent successful zero-ischaemia RPN; seven (20.6%) required conversion to main renal artery clamping (ischaemia time < 30 min) for the following reasons: persistent tumour fluorescence after clamping indicating inadequate tumoral devascularization (n = 5), and parenchymal bleeding during RPN (n = 2). Matched-pair analysis showed comparable outcomes between cohorts, except for longer operating time (256 vs 212 min, P = 0.02) and superior kidney function (reduction of estimated glomerular filtration rate (-1.8% vs -14.9%, P = 0.03) in the zero-ischaemia cohort. All surgical margins were negative. Conclusions In this pilot study, we show that zero-ischaemia RPN with NIRF is a safe alternative to conventional RPN with main renal artery clamping. Eliminating global ischaemia may improve functional outcomes at short-term follow-up.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [1] NEAR INFRA-RED FLUORESCENCE IMAGING TO FACILITATE SUPER-SELECTIVE ARTERIAL CLAMPING DURING ZERO-ISCHEMIA ROBOTIC PARTIAL NEPHRECTOMY
    Borofsky, Michael S.
    Gill, Inderbir S.
    Hemal, Ashok K.
    Marien, Tracy P.
    Jayaratna, Isuru
    Krane, Louis S.
    Stifelman, Michael D.
    [J]. JOURNAL OF ENDOUROLOGY, 2012, 26 : A163 - A163
  • [2] Feasibility of utilizing near-infrared fluorescence imaging with indocyanine green for super-selective arterial clamping in pure laparoscopic partial nephrectomy
    Lee, Han Jie
    Chen, Kenneth
    Molchanov, Robert
    Schwentner, Christian
    Sim, Allen Soon Phang
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2018, 25 (04) : 382 - 383
  • [3] Near-infrared fluorescence imaging using indocyanine green for zero-ischaemia laparoscopic partial nephrectomy
    Lee, H. J.
    Tiwari, R. V.
    Chen, K.
    Ho, S. S. H.
    Phang, S.
    Sim, A.
    [J]. BJU INTERNATIONAL, 2017, 119 : 45 - 45
  • [4] SELECTIVE ARTERIAL CLAMPING WITH AID OF NEAR-INFRARED FLUORESCENCE DURING LAPAROSCOPIC PARTIAL NEPHRECTOMY
    Macek, Petr
    Rozet, Francois
    Barret, Eric
    Salas, Rafael Sanchez
    Galiano, Marc
    Cathelineau, Xavier
    [J]. JOURNAL OF ENDOUROLOGY, 2012, 26 : A517 - A517
  • [5] SELECTIVE ARTERIAL CLAMPING WITH THE ASSISTANCE OF NEAR INFRARED FLUORESCENCE IMAGING FOR ROBOTIC ASSISTED LAPAROSCOPIC PARTIAL NEPHRECTOMY
    Marien, Tracy P.
    Borofsky, Michael S.
    Chiu, Yichun
    Stifelman, Michael D.
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 : A282 - A283
  • [6] ROBOTIC PARTIAL NEPHRECTOMY USING SELECTIVE ARTERIAL CLAMPING WITH NEAR INFRARED FLUORESCENCE IMAGING IN PATIENTS WITH ABSOLUTE INDICATIONS
    Bjurlin, Marc A.
    Wysock, James
    McClintock, Tyler R.
    Borofsky, Michael
    Sivarajan, Ganesh
    Sorin, Suzanne
    Stifelman, Michael D.
    [J]. JOURNAL OF UROLOGY, 2013, 189 (04): : E445 - E446
  • [7] ROBOTIC PARTIAL NEPHRECTOMY WITH SELECTIVE ARTERIAL CLAMPING USING NEAR INFRARED FLUORESCENCE IMAGING: NYU INITIAL EXPERIENCE
    Bjurlin, Marc
    Wysock, James
    McClintock, Tyler R.
    Borofsky, Michael
    Sivarajan, Ganesh
    Sorin, Suzanne
    Stifelman, Michael D.
    [J]. JOURNAL OF UROLOGY, 2013, 189 (04): : E488 - E488
  • [8] DIFFERENTIAL FLUORESCENCE FOR INTRAOPERATIVE MARGIN ASSESSMENT WITH NEAR-INFRARED FLUORESCENCE IMAGING DURING ROBOTIC PARTIAL NEPHRECTOMY
    Abaza, Ronney
    Rosenthal, Janice
    Gupta, Jatin
    [J]. JOURNAL OF UROLOGY, 2017, 197 (04): : E705 - E705
  • [9] Re: Can Selective Arterial Clamping with Fluorescence Imaging Preserve Kidney Function During Robotic Partial Nephrectomy?
    Lay, Aaron H.
    Cadeddu, Jeffrey A.
    [J]. EUROPEAN UROLOGY, 2015, 67 (03) : 592 - 592
  • [10] Re: Can Selective Arterial Clamping with Fluorescence Imaging Preserve Kidney Function during Robotic Partial Nephrectomy?
    Cadeddu, Jeffrey A.
    [J]. JOURNAL OF UROLOGY, 2015, 193 (02): : 458 - 458