Flow-injection biamperometric determination of epinephrine

被引:0
|
作者
Mateo, JVG
Kojlo, A
机构
[1] WARSAW UNIV BRANCH,INST CHEM,PL-15443 BIALYSTOK,POLAND
[2] UNIV POLITECN VALENCIA,DEPT QUIM,E-46071 VALENCIA,SPAIN
[3] COLEGIO UNIV CEU,DEPT QUIM,VALENCIA,SPAIN
关键词
biamperometry; flow injection; catecholamines; epinephrine; adrenaline;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection manifold is proposed for the determination of epinephrine. The experimental procedure is based on the indirect biamperometric detection of the drug by using Fe(III)-Fe(II) as an indicating redox system and a flow-through detector with two polarized Pt wire electrodes. The calibration graph is linear over the range 0.3-20 mu g ml(-1) of epinephrine. The relative standard deviation for the determination of 10 mu g ml(-1) of epinephrine is 1.5% (n = 25) and the sample throughput is 153 h(-1). The method was applied to the determination of epinephrine in two commercially available pharmaceutical preparations. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1821 / 1828
页数:8
相关论文
共 50 条
  • [1] Indirect flow-injection determination of catecholamines with biamperometric detection
    Wolyniec, E
    Kojlo, A
    [J]. JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2003, 21 (02): : 217 - 227
  • [2] A flow-injection biamperometric method for determination of pantoprazole in pharmaceutical tablets
    Castro, SL
    Pessoa-Neto, OD
    Santos, SRB
    Medeiros, EP
    Lima, RAC
    Martins, VL
    Araújo, MCU
    Santos, JCC
    Korn, M
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (04) : 1064 - 1068
  • [3] Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector
    Chuan Zhao
    Jun-feng Song
    Jun-cai Zhang
    [J]. Analytical and Bioanalytical Chemistry, 2002, 374 : 498 - 504
  • [4] A novel biamperometric biosensor for urinary oxalate determination using flow-injection analysis
    Milardovic, Stjepan
    Kerekovic, Irena
    Nodilo, Marijana
    [J]. TALANTA, 2008, 77 (01) : 222 - 228
  • [5] Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector
    Zhao, C
    Song, JF
    Zhang, JC
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) : 498 - 504
  • [6] BIAMPEROMETRIC TITRATION AND FLOW-INJECTION DETERMINATION OF CYCLAMATE IN LOW-CALORIE PRODUCTS
    FATIBELLO, O
    CAPELATO, MD
    CALAFATTI, SA
    [J]. ANALYST, 1995, 120 (09) : 2407 - 2412
  • [7] Flow-injection biamperometric direct determination of calcium dobesilate in irreversible couple system
    Song, JF
    Chen, JQ
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) : 789 - 796
  • [8] Flow injection biamperometric determination of captopril
    Palomeque, ME
    Band, BSF
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 547 - 552
  • [9] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [10] FLOW-INJECTION DETERMINATION OF NITRITE AND NITRATE WITH BIAMPEROMETRIC DETECTION AT 2 PLATINUM WIRE ELECTRODES
    HULANICKI, A
    MATUSZEWSKI, W
    TROJANOWICZ, M