Studies have shown that chromium from electroplating factories can cause respiratory problems to workers after prolonged exposure. Since Taiwan has a relatively high number of electroplating factories and minimal data regarding chromium's effect on workers, the authors undertook this study focusing on the size distribution of airborne hexavalent chromium and its concentration levels within the factory. Both area and personal sampling were conducted using a particle fractionating sampler. Samples were analyzed using visible spectrophotometry. A comparison of three types of factories-chromium, nickel-chromium, and zinc-showed that the highest concentrations were found in chromium electroplating factories near the electroplating tank Hexavalent chromium particles obtained from area sampling had mass median diameters between 1.67-6.38 mu m and 0.75-4.73 mu m for personal sampling. Particles of this high concentration and small size can enter and cause considerable damage to the respiratory tract.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [1] Concentration Characteristics of Airborne Hexavalent Chromium in the Industrial Area
    Kang, Byung-Wook
    Han, Jin-Seok
    Lee, Min-Do
    Lee, Hak Sung
    Kim, Jong-Ho
    Son, Eun-Seong
    Baek, Sung-Ok
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2009, 25 (03) : 179 - 187
  • [2] Replacing hexavalent chromium in electroplating
    ElSharif, M
    TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING, 1997, 75 : B143 - B146
  • [3] Distribution of airborne hexavalent chromium concentrations in large industrial complexes in Korea
    Kang B.-W.
    Lee H.-S.
    Kim J.-H.
    Hong J.-H.
    Kim R.-H.
    Seo Y.-K.
    Han J.-S.
    Baek K.-M.
    Kim M.-J.
    Baek S.-O.
    Asian Journal of Atmospheric Environment, 2016, 10 (4) : 208 - 216
  • [4] Efficiency of Penicillium chrysogenum PTCC 5037 in reducing low concentration of chromium hexavalent in a chromium electroplating plant wastewater
    Pazouki, M.
    Keyanpour-Rad, M.
    Shafie, Sh.
    Shahhoseini, Sh.
    BIORESOURCE TECHNOLOGY, 2007, 98 (11) : 2116 - 2122
  • [5] Airborne hexavalent chromium in southwestern Ontario
    Bell, RW
    Hipfner, JC
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (08): : 905 - 910
  • [6] Airborne hexavalent chromium in southwestern Ontario
    Bell, Ronald W.
    Hipfner, Jerold C.
    Journal of the Air and Waste Management Association, 1997, 47 (08): : 905 - 910
  • [7] Reclamation of Hexavalent Chromium from Electroplating Effluents by Electroextraction
    Revathi, M.
    Sundari, G. Sivagaami
    Basha, C. Ahmed
    Alam, Manawwer
    Sagadevan, Suresh
    Ahmad, Naushad
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (10) : 6547 - 6554
  • [8] Effects of Exposure to Hexavalent Chromium on Male Electroplating Workers
    Pan, Chih-Hong
    Shih, Tung-Sheng
    Chen, Chiou-Jong
    Hsu, Jin-Huei
    Huang, Yeou-Lih
    Wu, Ming-Tsang
    EPIDEMIOLOGY, 2009, 20 (06) : S202 - S202
  • [9] CONCENTRATION AND SIZE DISTRIBUTION OF AIRBORNE FERROMAGNETIC PARTICLES
    WIRTH, E
    PRODI, F
    TELLUS, 1972, 24 (06): : 561 - 567
  • [10] Characterization of concentration, particle size distribution, and contributing factors to ambient hexavalent chromium in an area with multiple emission sources
    Yu, Chang Ho
    Huang, Lihui
    Shin, Jin Young
    Artigas, Francisco
    Fan, Zhi-hua
    ATMOSPHERIC ENVIRONMENT, 2014, 94 : 701 - 708