Development of anatomically realistic PET and PET/CT phantoms with rapid prototyping technology

被引:18
|
作者
Miller, Michael. A. [1 ]
Hutchins, Gary D. [1 ]
机构
[1] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
关键词
D O I
10.1109/NSSMIC.2007.4437056
中图分类号
O59 [应用物理学];
学科分类号
摘要
The utility of PET and PET/CT in research and diagnosis of cancer, cardiac and neurological disorders has been widely demonstrated. Phantoms with well defined geometries that accurately model radiolabeled tracer concentrations and photon attenuation coefficients are suited for characterization of imaging systems, but not as well suited for evaluating methods sensitive to detailed anatomical structure, such as algorithms for monitoring tumor response. An ideal phantom would have the shape and activity distribution of a realistic tumor and would be useful in evaluation of automated image analysis systems. Such a phantom, imaged at sites involved in clinical trials, would be valuable for evaluating consistency and accuracy. We have developed a method of creating such phantoms by incorporating radioactive tracer as dye for a cellulose powder based rapid prototyping system. This allows us to create phantoms with spatial resolution limited only by the stereolithography printer system (slice thickness is 0.18 mm, printing resolution is 600 dpi). We have evaluated the method by printing several small phantoms with 18F and measuring activity in a gamma counter. The relative standard deviation of the activity of multiple identical phantoms was 2%. Activity in unlabeled parts was less than 2% of adjacent labeled regions. We have created and printed realistic phantoms based on the SPL human brain atlas [1, 2], the Paxinos & Watson rat brain atlas [3] and from PET/CT images of human lung nodules, showing that this is a practical method for making complex radioactive phantoms that model real anatomy. We are proceeding with further development to allow us to produce phantoms with multiple activity concentrations, tunable photon attenuation coefficients and long lived isotopes.
引用
收藏
页码:4252 / 4257
页数:6
相关论文
共 50 条
  • [1] A novel 4D-phantom using rapid prototyping of anatomically realistic tumor models for evaluation of PET/CT and PET-guided radiotherapy
    Kurth, Jens
    Gocke, Christian
    Jonuchies, Ingo
    Hildebrandt, Guido
    Krause, Bernd Joachim
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [2] DEVELOPMENT OF A RANGE OF ANATOMICALLY REALISTIC RENAL ARTERY FLOW PHANTOMS
    King, Deirdre M.
    Ring, Michael
    Moran, Carmel M.
    Browne, Jacinta E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (07): : 1135 - 1144
  • [3] VirtualDose: A CT dose reporting software based on anatomically realistic phantoms
    Ding, Aiping
    Gu, Jianwei
    Mille, Matthew
    Xu, X. George
    Liu, Bob
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] PET AND PET/CT TECHNOLOGY FOR RADIATION THERAPY
    Beyer, T.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S5 - S6
  • [5] Design and Manufacture of Anatomically Realistic, Actuated, Elastic Lung Inserts for PET/CT Phantom Studies with Respiratory Motion
    Black, D.
    Oloumi, Y.
    Wong, J.
    Fedrigo, R.
    Uribe, C.
    Kadrmas, D.
    Rahmim, A.
    Klyuzhin, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E392 - E392
  • [6] Development and Testing of a CT Dose Software "VirtualDose" Using Anatomically Realistic Patient Phantoms: Preliminary Results for the Phase / of the Project
    Ding, A.
    Gu, J.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [7] TOWARD QUANTITATIVE X-RAY CT PHANTOMS OF METASTATIC TUMORS USING RAPID PROTOTYPING TECHNOLOGY
    Yoo, Terry S.
    Hamilton, Trevor
    Hurt, Darrell E.
    Caban, Jesus
    Liao, David
    Chen, David T.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1770 - 1773
  • [8] Development of a Vessel-Mimicking Material for use in Anatomically Realistic Doppler Flow Phantoms
    Medical Ultrasound Physics and Technology Group, School of Physics and FOCAS Institute, Dublin Institute of Technology, Dublin, Ireland
    不详
    不详
    不详
    Ultrasound Med. Biol., 5 (813-826):
  • [9] DEVELOPMENT OF AVESSEL-MIMICKING MATERIAL FOR USE IN ANATOMICALLY REALISTIC DOPPLER FLOW PHANTOMS
    King, Deirdre M.
    Moran, Carmel M.
    McNamara, John D.
    Fagan, Andrew J.
    Browne, Jacinta E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (05): : 813 - 826
  • [10] Stylized MIRD Phantoms Should Be Replaced by Anatomically Realistic Phantoms: Discrepancies In Red Bone Marrow Doses From CT Scans
    Liu, H.
    Zhang, J.
    Caracappa, P. F.
    Xu, X.
    MEDICAL PHYSICS, 2009, 36 (06)